欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Denon-AVRX4400H-avr-sm维修电路原理图.pdf

    • 资源ID:101548       资源大小:19.42MB        全文页数:213页
    • 资源格式: PDF        下载积分:35积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Denon-AVRX4400H-avr-sm维修电路原理图.pdf

    START:|sX3k6VQNaf/6VbQg1Aav9Q=|4T5qXRrOj24wm8HR+zKOBrbK30+wiKuaxR52txZH6yk=|XOIUVeyoWOE5XcWqSdEcbA=|:END INTEGRATED NETWORK AV RECEIVER AVR-X4400H Click here! On-line service parts list Online Parts List (P5 to P7) WEB owners manual (Release schedule) (July 2017) (July 2017) (September 2017) CAUTION IN SERVICING ELECTRICAL MECHANICAL REPAIR INFORMATION UPDATING Service Manual Ver. 1 Forpurposesofimprovement,specificationsanddesignaresubjecttochangewithoutnotice. Pleaseusethisservicemanualwithreferringtotheoperatinginstructionswithoutfail. Someillustrationsusinginthisservicemanualareslightlydifferentfromtheactualset. RadioFans.CN 收音机爱 好者资料库 CAUTION IN SERVICING SAFETY PRECAUTIONS NOTE FOR SCHEMATIC DIAGRAM NOTE FOR PARTS LIST INSTRUCTIONS FOR HANDLING SEMICONDUCTORS AND OPTICAL UNIT Online Parts List Accessing the Parts List Logging in to New SDI and Accessing the Parts List Accessing the Part List from the Model Asset Screen PRINTED CIRCUIT BOARDS Parts Table Downloading the Parts List as an Excel File Revision History Searching Part Numbers or Ref. Numbers CAUTION IN SERVICING. Initializing This Unit JIG FOR SERVICING 2 Caution in servicing ElectricalMechanicalRepair InformationUpdating RadioFans.CN 收音机爱 好者资料库 The following items should be checked for continued protection of the customer and the service technician. Leakage current check Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable. CAUTION Please heed the following cautions and instructions during servic- ing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock! (1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when replacing parts, for example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed! For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mount- ed away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and the structural parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replacement parts with higher rat- ings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams Indicated by the z mark. (2) Parts lists Indicated by the z mark. The use of parts other than the designated parts could cause electric shocks, fires or other dangerous situations. CAUTION Concerning important safety parts SAFETY PRECAUTIONS 3 Caution in servicing ElectricalMechanicalRepair InformationUpdating WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer. CAUTION: Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DO NOT return the set to the customer unless the problem is identified and remedied. NOTICE: ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. N INDICATES NANO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. 1. Parts indicated by nsp on this table cannot be supplied. 2. When ordering a part, make a clear distinction between 1 and I (i) to avoid mis-supplying. 3. A part ordered without specifying its part number can not be supplied. 4. Part indicated by mark is not illustrated in the exploded view. WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer. Electrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential differ- ence caused by electrostatic charge during unpacking or repair work. 1. Ground for Human Body Be sure to wear a grounding band (1 M ohm) that is properly grounded to remove any static electricity that may be charged on the body. 2. Ground for Workbench Be sure to place a conductive sheet or copper plate with proper grounding (1 M ohm) on the work- bench or other surface, where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing CBA Grounding Band Conductive Sheet or Copper Plate 1M 1M CBA NOTE FOR SCHEMATIC DIAGRAM NOTE FOR PARTS LIST INSTRUCTIONS FOR HANDLING SEMICONDUCTORS AND OPTICAL UNIT 4 Caution in servicing ElectricalMechanicalRepair InformationUpdating Online Parts List Accessing the Parts ListLogging in to New SDI and Accessing the Parts List (1) Click the URL link on the cover of the service manual. Examples of display NOTE : If the web browser does not open automatically, copy the URL and paste it into the address bar of the web browser and then press Enter. (2) When the login screen is displayed, enter your username and password. (3) Enter the 5 letters shown as the blue CAPTCHA code as single-byte characters. If the text is unclear, click Refresh to change the CAPTCHA code, and enter it again. (4) Press the Login button. (1) Access New SDI from the URL below. (2) When the login screen is displayed, enter your username and password. (3) Enter the 5 letters shown as the blue CAPTCHA code as single-byte characters. If the text is unclear, click Refresh to change the CAPTCHA code, and enter it again. (4) Press the Login button. (5) When the Home screen is displayed, click Advanced Search. (6) Enter the following search conditions and click Search. Keyword : Model name Brand : brand name Asset Type : Part list (7) Click the model name when the search results are displayed. 5 Caution in servicing ElectricalMechanicalRepair InformationUpdating Downloading the Parts List as an Excel File Revision History (1) Displays the Parts List. Click the Download icon. (1) Click Revision history in the blue bar. The following details are displayed. Sheet : Name of the changed sheet Description : Description of the changes Remarks : Destination, color information Factories : Factory number Ver : Version number after revision if changes were made to the parts list Date : Date of changes Accessing the Part List from the Model Asset Screen PRINTED CIRCUIT BOARDS Parts Table (1) Display Model Asset from New SDI. (2) Click the section displayed as Link to Part Lists under the model name. NOTE : If the Link to Parts List section is not displayed, download the parts table from the Asset list. (1) Display the Parts List. Click the PCB name in the blue bar to display the parts list for the board. Left and right arrow icons are displayed if the circuit board name does not fit in the blue bar. Click these icons to display a different part of the name when necessary. Icons to move the circuit board name left and right in the blue bar 6 Caution in servicing ElectricalMechanicalRepair InformationUpdating Searching Part Numbers or Ref. Numbers You can search a Parts List for part numbers or Ref. numbers. (1) Enter the part number or Ref. number in the search window of the Parts List, and press the search button. (2) The search results are displayed. The name of the sheet in which the search part is used and the parts line are displayed. (3) Next, click the Sheet section of the search results. (4) The Board Part Table opens and the line on which the searched part number appears is highlighted. 7 Caution in servicing ElectricalMechanicalRepair InformationUpdating Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the digital PCB. 1. Press the power button to turn off the power. 2. While holding down buttons CURSOR d and CURSOR f simultaneously, press the power button to turn on the power. 3. Release the buttons after confirming that the display flashes at 1-second intervals. The unit is initialized. Use network initialization mode to initialize the network related settings. NOTE: If the unit fails to enter the service mode in step 3, repeat the procedure from step 1. Initializing the device restores the customized settings to the factory settings. Write down your settings in advance and reconfigure the settings after initialization. Use the following jigs (extension cable kit) when repairing the PCBs. Order with your dealer for the jigs your dealer if necessary. 8U-110084S : EXTENSION UNIT KIT : 1 Set 8U-110136S : EXTENSION UNIT KIT : 1 Set (See JIG FOR SERVICING) CURSOR d CURSOR fX JIG FOR SERVICING Initializing This Unit CAUTION IN SERVICING. 8 Caution in servicing ElectricalMechanicalRepair InformationUpdating ELECTRICAL SCHEMATIC DIAGRAMS SCH01_DIGITAL CONNECT SCH02_DIGITAL POWER SCH03_MAIN CPU SCH04_EXPANDER SCH05_CPU LEVEL CHG SCH06_DIR SCH07_AUDIO PLD SCH08_DSP1 SCH09_DSP2 SCH10_DSP3 SCH11_DSP4 SCH12_ADC SCH13_ZONE, LEGO DAC SCH14_LEGO SCH15_VIDEO DECODER SCH16_HDMI SW2 SCH17_HDMI SW1 SCH18_VSP must connect recommended filter 44VCOMONoADC common voltage output; must connect external decoupling capacitor 45AGNDADGround, for ADC analog 46VCCADPower supply, 5.0 V (typ.), for ADC analog 47VINLINoADC analog voltage input, left channel 48VINRINoADC analog voltage input, right channel (1) Schmitt trigger input (2) Schmitt trigger input (3) Open-drain configuration in I2C mode (4) Onboard pull-down resistor (50 k , typical) (5) CMOS Schmitt trigger input PCM9211 BLOCK DIAGRAM Clock/Data Recovery MPIO_A SELECTOR MPIO_C SELECTOR MPIO _B SELECTOR ADC Com. Supply MPO0/1 SELECTOR MPO0 MPO1 MAIN OUTPUT SCKO BCK LRCK DOUT PORT RXIN8 RXIN9 RXIN10 RXIN11 DITOUT AUTO DIR ADC AUXIN0 AUXIN1 AUXIN2 AUTO DIR ADC AUXIN0 AUXIN1 AUXIN2 AUTO DIR ADC AUXIN0 AUXIN1 DIT Lock:DIR Unlock:ADC AUXIN2 AUXOUT OSC Divider XMCKO Divider XMCKO DITOUT RECOUT0 RECOUT1 AUXIN0 AUXIN1 ADC Standalone ADC Mode Control Function Control REGISTER POWER SUPPLY MC /SCL MDI/SDA MDO /ADR0 MS/ADR1 FILT PLL DIR Lock Detection ERROR/INT0 NPCM/INT1 ADC Clock (SCK/BCK/LRCK) (To MPIO _A & MPO0/1) ADC MODE DIR CS (48-bit) DIT CS (48-bit) DIR Interrupt GPIO/GPO Data MPIO_A MPIO_B MPIO_C MPO0 MPO1 Divider (to MPIO_A) Secondary BCK/LRCK Selector RECOUT0 RECOUT1 SBCK/SLRCK DOUT RXIN7 SCKO/BCK/LRCK RXIN0 RXIN1 RXIN2 RXIN4/ASCKI0 RXIN3 RXIN5/ABCKI0 RXIN6/ALRCKI0 RXIN7/ADIN0RXIN7 RXIN6 RXIN5 RXIN4 RXIN3 RXIN2 RXIN1 RXIN0 MPIO_A0 MPIO_A1 MPIO_A2 MPIO_A3 VINL VINR VCOM MPIO _C0 MPIO _C1 MPIO _C2 MPIO _C3 XTI XTO AGNDVDDRXGNDRXDVDDVCCADAGNDADDGNDVCC ADC ANALOG DIR ANALOG ALL DIR ANALOG SPI/I C INTERFACE 2 Reset and Mode Set All Port f Calculator S DIR f Calculator S DIR P and P CD EXTRA DIR FUNCTIONS f Calculator S ERROR DETECTION Non-PCM DETECTION Flags DTS-CD/LD Detection Validity Flag User Data Channel Status Data BFRAME Detection Interrupt System MPIO_B3 MPIO_B2 MPIO_B1 MPIO_B0 RST PCM9211 SBAS495 JUNE 2010 BLOCK DIAGRAM Copyright 2010, Texas Instruments IncorporatedSubmit Documentation Feedback9 Product Folder Link(s): PCM9211 68 Caution in servicing ElectricalMechanicalRepair InformationUpdating ADSP21487KSWZ4B (DIGITAL : IC251 / IC261 / IC271 / IC281) Terminal Function TOP VIEW (PINS DOWN) 1 44 45 89 88 132 176133 PIN 1 GND PAD (PIN 177) at BOTTOM Pin NamePin No.Pin NamePin No.Pin NamePin No.Pin NamePin No. SDDQM1VDD_EXT45DAI_P1089VDD_INT133 MS02DPI_P08 46VDD_INT90FLAG0134 SDCKE3DPI_P07 47VDD_EXT91FLAG1135 VDD_INT4VDD_INT48DAI_P2092FLAG2136 CLK_CFG15DPI_P09 49VDD_INT93NC137 ADDR06DPI_P10 50DAI_P08 94FLAG3138 BOOT_CFG07DPI_P1151DAI_P14 95NC139 VDD_EXT8DPI_P12 52DAI_P04 96NC140 ADDR19DPI_P13 53DAI_P18 97VDD_EXT141 ADDR210DPI_P14 54DAI_P17 98NC142 ADDR311DAI_P0355 DAI_P16 99VDD_INT143 ADDR412NC56DAI_P12 100TRST144 ADDR513VDD_EXT57DAI_P15 101NC145 BOOT_CFG114NC58VDD_INT102EMU146 GND15NC59DAI_P11 103DATA0147 ADDR616NC60VDD_EXT104DATA1148 ADDR717NC61VDD_INT105DATA2149 NC18 VDD_INT62BOOT_CFG2106 DATA3150 NC19NC63VDD_INT107TDO151 ADDR820NC64AMI_ACK108DATA4152 ADDR921VDD_INT65GND 109VDD_EXT153 CLK_CFG022NC66THD_M110D

    注意事项

    本文(Denon-AVRX4400H-avr-sm维修电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2023 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开