欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Bose-1800V-pwr-sup1维修电路原理图.pdf

    • 资源ID:142878       资源大小:321.44KB        全文页数:5页
    • 资源格式: PDF        下载积分:8积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Bose-1800V-pwr-sup1维修电路原理图.pdf

    1CAUTION: THE 1800-V PROFESSIONAL STEREO POWERAMPLIFIER SYSTEM CONTAINS NO USER-SERVICEABLE PARTS.TO PREVENT WARRANTY INFRACTIONS, REFER SERVICING TOWARRANTY SERVICE STATIONS OR FACTORY SERVICE.PROPRIETARY INFORMATIONTHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OFBOSE CORPORATION WHICH IS BEING FURNISHED ONLY FORTHE PURPOSE OF SERVICING THE IDENTIFIED BOSE PRODUCTBY AN AUTHORIZED BOSE SERVICE CENTER OR OWNER OF THEBOSE PRODUCT, AND SHALL NOT BE REPRODUCED OR USEDFOR ANY OTHER PURPOSE.Table of ContentsSAFETY INFORMATION. 2SUPPLEMENT OVERVIEW AND PROCEDURES . 3Figure 1. 1800-V Amplifier PCB. 4Figure 2. 1800-V Power Supply PCB . 4Figure 3. 1800-V Regulator PCB . 4RadioFans.CN 收音机爱 好者资料库21. Parts that have special safety characteristics are identified by the symbol onschematics or by special notes on the parts list. Use only replacement parts that havecritical characteristics recommended by the manufacturer.2. Make leakage current or resistance measurements to determine that exposed partsare acceptably insulated from the supply circuit before returning the unit to thecustomer. Use the following checks to perform these measurements:A. Leakage Current Hot Check-With the unit completely reassembled, plug the ACline cord directly into a 120V AC outlet. (Do not use an isolation transformer duringthis test.) Use a leakage current tester or a metering system that complies withAmerican National Standards Institute (ANSI) C101.1 Leakage Current for Appli-ances and Underwriters Laboratories (UL) 1492 (71). With the unit AC switch first inthe ON position and then in OFF position, measure from a known earth ground(metal waterpipe, conduit, etc.) to all exposed metal parts of the unit (antennas,handle bracket, metal cabinet, screwheads, metallic overlays, control shafts, etc.),especially any exposed metal parts that offer an electrical return path to the chassis.Any current measured must not exceed 0.5 milliamp. Reverse the unit power cordplug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE LIM-ITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUSTBE ELIMINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER.B. Insulation Resistance Test Cold Check-(1) Unplug the power supply and con-nect a jumper wire between the two prongs of the plug. (2) Turn on the power switchof the unit. (3) Measure the resistance with an ohmmeter between the jumpered ACplug and each exposed metallic cabinet part on the unit. When the exposed metallicpart has a return path to the chassis, the reading should be between 1 and 5.2Megohms. When there is no return path to the chassis, the reading must be infi-nite. If it is not within the limits specified, there is the possibility of a shock hazard,and the unit must be repaired and rechecked before it is returned to the customer.SAFETY INFORMATION!RadioFans.CN 收音机爱 好者资料库3This supplement provides two additional test procedures, which will assist in the diagnosisand repair of the 1800-V Amplifier.Use the following procedures to check and adjust the Output Bias and High-voltage Rails.Channel 1 and 2 Output Bias Adjust:NOTE: The bias should be set without an input signal or load on the outputs.The components involved in this procedure are located on the Amplifier PCB, refer toFigure 1 for their location.To adjust the bias of Channel 1, measure across one of the output emitter resistors(R146, R148, R150, R151 and R153) with a DC meter (the DC meters -input should befloated). Adjust R124 until the DC meter reads 1 mV. To ensure that the emitter resistorsshare the bias current equally, its recommended that two or three be measured. Equal biascurrent sharing is indicated by a 1 mV voltage drop across each emitter resistor.To adjust the bias of Channel 2, measure across one of the output emitter resistors(R246, R248, R250, R251 and R253) with a DC meter (the DC meters -input should befloated). Adjust R224 until the DC meter reads 1 mV. To ensure that the emitter resistorsshare the bias current equally, its recommended that two or three be measured. Equal biascurrent sharing is indicated by a 1 mV voltage drop across each emitter resistor.High-voltage Rail Adjust:NOTE: The rail voltages should be set with the line voltage at its nominal value and withoutan input signal or output load.The Test Points TP1, TP2 and TP3 are located on the Power Supply PCB, refer to Figure 2.Potentiometer R36 is located on the Regulator PCB, refer to Figure 3.To adjust the high-voltage rail use a DC meter to measure across TP1 and TP3. Adjust R36on the Regulator PCB until the meter reads -106 volts ( 2 VDC). The reading across TP1and TP2 should be approximately +104 volts.SUPPLEMENT OVERVIEW AND PROCEDURESFigure 1. 1800-V Amplifier PCBFigure 3. 1800-V Regulator PCBFigure 2. 1800-V Power Supply PCBFOR TECHNICAL ASSISTANCE OR PART ORDERS, CALL 1-800-367-4008P/N 181812-S1 12/95SPECIFICATIONS AND FEATURES SUBJECT TO CHANGE WITHOUT NOTICEBose CorporationThe MountainFramingham, Massachusetts USA 01701

    注意事项

    本文(Bose-1800V-pwr-sup1维修电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2023 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开