欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    IC-706MK2G_service_menu.pdf

    • 资源ID:194072       资源大小:33.91KB        全文页数:2页
    • 资源格式: PDF        下载积分:6积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    IC-706MK2G_service_menu.pdf

    4-5 SET MODE ADJUSTMENT 4 - 10 ENTERING ADJUSTMENT SET MODE Id APC FILTER CALIBRATION POWER METER (14 MHz) TUNING POWER (14 MHz) (50 MHz) POWER METER (145 MHz) POWER METER (430 MHz) ALC METER SWR METER ADJUSTMENTADJUSTMENT CONDITIONDISPLAYOPERATION Enter adjustment set mode: 1 Turn power OFF. 2 Terminate the REMOTE jack with a 3.5(d) mm mini-plug. 3 While pushing P.AMP/ATT and TUNE/CALL, turn power ON. Connect an RF power meter to ANT1 connector. Connect a DC ammeter between the DC power supply and transceivers DC power socket (P601 on the PA unit). Transmit using an external PTT switch. Connect an RF power meter to ANT1 connector. Connect an RF power meter to ANT1 connector. Transmit using an external PTT switch. Transmit using an external PTT switch. Connect an RF power meter to ANT1 connector. Transmit using an external PTT switch. Transmit using an external PTT switch. Connect an RF power meter to ANT2 connector. Transmit using an external PTT switch. Transmit using an external PTT switch. Connect an RF power meter to ANT2 connector. Transmit using an external PTT switch. Transmit using an external PTT switch. Connect an RF power meter to ANT1 connector. Connect an audio generator to MIC con- nector and set as : Level: 1.5 kHz/30mV Transmit using an external PTT switch. Connect a 50 dummy load or power meter to ANT1 connector. Connect a 50 dummy load or power meter to ANT1 connector. 1 1 1 1 2 1 2 1 2 1 2 1 1 2 SET IdAPC GO FILTER CAL SET 90 % SET 50 % SET TUNE Po SET TUNE Po SET 90 % SET 50 % SET 90 % SET 50 % ALC START SWR 1 LOAD SWR 2 LOAD Push F-3 (TX) to enter the TX adjustment setting mode. Then advance to the following set- ting, or push UP/DN to scroll the display. Set a total current at 15 A by adjust- ing R1125 on the MAIN board. Push MENU to set the SET IdAPC after returning receiving con- dition. Push and hold MENU (GO) to make the calibration. Transceiver transmits for a while. Set to 90 W using MAIN DIAL, then push MENU while transmitting. Set to 50 W using MAIN DIAL, then push MENU while transmitting. Set to 10 W using MAIN DIAL, then push MENU while transmitting. Set to 10 W using MAIN DIAL, then push MENU while transmitting. Set to 45 W using MAIN DIAL, then push MENU while transmitting. Set to 25 W using MAIN DIAL, then push MENU while transmitting. Set to 18 W using MAIN DIAL, then push MENU while transmitting. Set to 10 W using MAIN DIAL, then push MENU while transmitting. Push and hold MENU to set ALC reference level while transmitting. Push MENU to set SWR reference level. Push MENU to set SWR2 level. The display returns to the same as the ADUSTMENT SET MODE above. USB RX? TX Push F-1 (EXIT) to exit adjustment set mode. SET MODE ADJUSTMENT (continued) ENTERING ADJUSTMENT SET MODE SENSITIVITY S-METER Enter adjustment set mode: 1 Turn power OFF. 2 Terminate the REMOTE jack with a 3.5(d) mm mini-plug. 3 While pushing P.AMP/ATT and TUNE/CALL, turn power ON. Connect a standard signal generator to ANT2 and set as: Frequency: 60.05150 MHz Modulation: OFF Receiving Connect an SSG to ANT1 connector and set as: Frequency: 14.1515 MHz Level: OFF Receiving Set an SSG as: Level: 50 V (73 dBm) Modulation: OFF Receiving Set an SSG as : Level: 50 mV (13 dBm) Modulation: OFF Receiving VHF1 BPF1 L S0 LEVEL S9 LEVEL +60dB LEVEL Push F-2 (RX) to enter the RX adjustment setting mode. Then advance to the following set- ting, or push UP/DN to scroll the display. Set a connected SSGs level at 10 dB of S/N ratio with AC millivolt- meter. Set maximum AF level using the MAIN DIAL, then push MENU to set the VHF1 BPF1 L. Push MENU to set the S0 level. Push MENU to set the S9 level. Push MENU to set the +60 dB level. The display returns to the same as the ADUSTMENT SET MODE above. Push F-1 (EXIT) to exit adjustment set mode. 4 - 11 ADJUSTMENTADJUSTMENT CONDITIONDISPLAYOPERATION 1 1 2 3 1 2 3 USB RX? TX Same operation as step 2 for the listed BPFs. Set an SSG as: Modulation: OFF VHF1 BPF2 L: 60.05150 MHz VHF1 BPF1 M: 90.50150 MHzVHF1 BPF2 M: Same as left VHF1 BPF1 H: 128.9515 MHzVHF1 BPF2 H: Same as left VHF2 BPF1 L: 129.1015 MHzVHF2 BPF2 L: Same as left VHF2 BPF1 M: 145.1515 MHzVHF2 BPF2 M: Same as left VHF2 BPF1 H: 170.0015 MHzVHF2 BPF2 H: Same as left UHF BPF1 L: 400.0015 MHzUHF BPF2 L: Same as left UHF BPF1 M: 435.1515 MHzUHF BPF2 M: Same as left UHF BPF1 H: 470.0015 MHzUHF BPF2 H: Same as left Receiving

    注意事项

    本文(IC-706MK2G_service_menu.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开