欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    IC-7410_FCC_test_report_2010.pdf

    • 资源ID:194864       资源大小:350.47KB        全文页数:32页
    • 资源格式: PDF        下载积分:10积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    IC-7410_FCC_test_report_2010.pdf

    HF/50 MHz Transceiver Model No.: IC-7410 FCC ID: AFJ318200 Applicant: ICOM Incorporated 1-1-32, Kamiminami, Hirano-ku Osaka, Japan, 547-0003 Tested in Accordance With Federal Communications Commission (FCC) 47 CFR, Part 15, Subpart B Scanning Receivers Operating in the Frequency Band 0.03 MHz - 60 MHz (excluding cellular bands) UltraTechs File No.: ICOM-263F15B121 This Test report is Issued under the Authority of Tri M. Luu, BASc Vice President of Engineering UltraTech Group of Labs Date: December 10, 2010 Report Prepared by: Dan Huynh Issued Date: December 10, 2010 Tested by: Wayne Wu, EMI/RFI Technician Test Dates: December 1, 2, 6 Class B Conducted, Quasi-Peak FCC 15; Class B Conducted, Average -20 -10 0 10 20 30 40 50 60 70 80 110 dBuVLine Tested: Hot Ant 2 Receiving Mode 12/10/2010 6:54:35 AM(Start = 0.15, Stop = 30.00) MHz Current List Frequency Peak QP Delta QP-QP Limit Avg Delta Avg-Avg Limit Trace Name MHz dBuV dBuV dB dBuV dB 0.183 27.5 23.4 -40.9 17.5 -36.8 Hot Line 0.289 26.8 21.3 -39.2 15.3 -35.2 Hot Line 1.043 35.2 33.7 -22.3 32.9 -13.1 Hot Line 19.614 22.6 18.3 -41.7 12.3 -37.7 Hot Line FCC PARTS 15 SUBPART B Section 15.121 Page 11 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) Plot 5.4.4.2. Power Line Conducted Emissions, Return Line Line Voltage: 13.8 VDC Line Tested: Return Line Current Graph Current Graph Return Line FCC 15; Class B Conducted, Quasi-Peak FCC 15; Class B Conducted, Average -20 -10 0 10 20 30 40 50 60 70 80 110 dBuVLine Tested:Return Ant 2 Receiving Mode 12/10/2010 7:16:38 AM(Start = 0.15, Stop = 30.00) MHz Current List Frequency Peak QP Delta QP-QP Limit Avg Delta Avg-Avg Limit Trace Name MHz dBuV dBuV dB dBuV dB 0.160 28.8 24.2 -41.3 18.4 -37.0 Return Line 1.043 35.6 34.1 -21.9 33.4 -12.6 Return Line 1.532 26.6 23.4 -32.6 20.1 -25.9 Return Line 9.396 23.0 18.0 -42.0 12.2 -37.8 Return Line FCC PARTS 15 SUBPART B Section 15.121 Page 12 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) 5.5. RECEIVER ANTENNA POWER SPURIOUS/HARMONIC CONDUCTED EMISSIONS 15.111(a) 5.5.1. Limits Receivers that operate (tune) in the frequency range 30 to 960 MHz and CB receivers that provides terminals for the connection of an external antenna may be tested to demonstrate compliance with the provisions of 15.109 with the antenna terminals shielded and terminated with a resistive termination equal to the impedance specified for the antenna, provided these receivers also comply with the following:- With the receiver antenna terminal connected to a resistive termination equal to the impedance specified or employed for the antenna, the power at the antenna terminal at frequency within the range from 30 MHz to 5th harmonic of the highest frequency shall not exceed 2.0 nanowatts (or -57 dBm 50 Ohm). 5.5.2. Method of Measurements Refer to Ultratech Test Procedures ULTR-P001-200 replacing a plug-in semiconductor chip; or programming a semiconductor chip using special access codes or an external device, such as a personal computer. Scanning receivers, and frequency converters designed for use with scanning receivers, also shall be incapable of converting digital cellular communication transmissions to analog voice audio. (2) Be designed so that the tuning, control and filtering circuitry is inaccessible. The design must be such that any attempts to modify the equipment to receive transmissions from the Cellular Radiotelephone Service likely will render the receiver inoperable. b. Except as provided in paragraph (c) of this section, scanning receivers shall reject any signals from the Cellular Radiotelephone Service frequency bands that are 38 dB or lower based upon a 12 dB SINAD measurement, which is considered the threshold where a signal can be clearly discerned from any interference that may be present. c. Scanning receivers and frequency converters designed or marketed for use with scanning receivers, are not subject to the requirements of paragraphs (a) and (b) of this section provided that they are manufactured exclusively for, and marketed exclusively to, entities described in 18 U.S.C. 2512(2), or are marketed exclusively as test equipment pursuant to Sec. 15.3(dd) d. Modification of a scanning receiver to receive transmissions from Cellular Radiotelephone Service frequency bands will be considered to constitute manufacture of such equipment. This includes any individual, individuals, entity or organization that modifies one or more scanners. Any modification to a scanning receiver to receive transmissions from the Cellular Radiotelephone Service frequency bands voids the certification of the scanning receiver, regardless of the date of manufacture of the original unit. In addition, the provisions of Sec. 15.23 shall not be interpreted as permitting modification of a scanning receiver to receiver cellular radiotelephone service transmissions. e. Scanning receivers and frequency converters designed for use with scanning receivers shall not be assembled from kits or marketed in kit form unless they comply with the requirements in paragraph (a) through (c) of this section. FCC PARTS 15 SUBPART B Section 15.121 Page 25 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) f. Scanning receivers shall have a label permanently affixed to the product, and this label shall be readily visible to the purchaser at the time of purchase. The label shall read as follows: WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. (1) Permanently affixed means that the label is etched, engraved, stamped, silkscreened, indelible printed or otherwise permanently marked on a permanently attached part of the equipment or on a nameplate of metal, plastic or other material fastened to the equipment by welding, riveting, or permanent adhesive. The label shall be designed to last the expected lifetime of the equipment in the environment in which the equipment may be operated and must not be readily detachable. The label shall not be a stick-on, paper label. (2) When the device is so small that it is not practicable to place the warning label on it, the information required by this paragraph shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user and shall also be placed on the container in which the device is marketed. However, the FCC identifier must be displayed on the device. FCC PARTS 15 SUBPART B Section 15.121 Page 26 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) 5.7.2. Declaration for Compliance with FCC 15.121 Comply with FCC 121(a)(1) This Scanning Receiver is incapable of operating (tuning), or readily being altered by the user to operate, within the frequency bands allocated to the Cellular Radiotelephone Service in part 22 of this chapter (cellular telephone bands). Please refer to ICOM attestation letter conforming compliance with this requirement. Comply with FCC 121(a)(2) This Scanning Receiver is designed so that the tuning, control and filtering circuitry is inaccessible. The design is such that any attempts to modify the equipment to receive transmissions from the Cellular Radiotelephone Service likely will render the receiver inoperable. Please refer to ICOM attestation letter conforming compliance with this requirement. Comply with FCC 121(b) Please refer to the following Section of this Test Report for Scanning Receivers Cellular Band Rejection test. Comply with FCC 121(c) Not applicable. Comply with FCC 121(d) The Users Manual of this Scanning Receiver is provided with the Warning statement as below. CAUTION: Changes or modifications to this device, not expressly approved by ICOM Inc., could void your authority to operate this device under FCC regulations. Comply with FCC 121(e) This Scanning Receiver is not assembled from kits or marketed in kit form. Comply with FCC 121(f) Scanning receivers shall have a label permanently affixed to the product, and this label shall be readily visible to the purchaser at the time of purchase. The label reads as follows: WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. FCC PARTS 15 SUBPART B Section 15.121 Page 27 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) 5.8. SCANNING RECEIVERS CELLULAR BAND REJECTION 15.121(b) 5.8.1. Limits Except as provided in paragraph (c) of this section, scanning receivers shall reject any signals from the Cellular Radiotelephone Service frequency bands that are 38dB or lower based upon a 12dB SINAD measurement, which is considered the threshold where a signal can be clearly discerned from any interference that may be present. 5.8.2. Method of Measurements (1) Connected the EUT as shown in the following block diagram (2) Apply a standard RF signal to the receiver input port (3) Adjust the audio output signal of the receiver to its rated value with the distortion less than 10% (4) Adjust the RF Signal Generator Output Power to produce 12 dB SINAD without the audio output power dropping by more than 3 dB (5) Repeat step (4) at lowest, middle and highest channel frequencies across all cellular base station band to establish a reference sensitivity level. The reference sensitivity taken was the lowest or worse-case sensitivity for all of the bands. (6) Adjust the RF Signal Generator output to a level of +60 dB above the reference sensitivity obtained in step (5) (7) Set the Receiver squelch threshold (the signal required to open the squelch) no greater than +20 dB above the reference sensitivity level. (8) Put the receiver in a scanning mode and allow it to scan across its complete receive range (9) If the receiver unsquelched or stopped on any frequency, the display frequency is recorded. The signal generator output level was then adjusted until 12 dB SINAD from the receiver was produced. The signal generator level associated with this response was also noted. (10) Repeat this procedure for 3 frequencies in the cellular base station transmit band. (11) The difference between the signal generator output for any response recorded and reference sensitivity is the rejection ratio RF Signal Generator EUTDistortion Analyzer RF Signal Generator Combiner FCC PARTS 15 SUBPART B Section 15.121 Page 28 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) 5.8.3. Test Data Remark: Cellular Transmitter Test frequencies are 824.04, 836.40, 848.97, 869.04, 880.62 and 893.97 MHz. 5.8.3.1. AM Mode EUTs Scanning Frequency Band (MHz) Cellular Transmitter Test Frequencies (MHz) RF Input Signal Level Cellular Frequencies for 12 dB SINAD (dBm) Reference Sensitivity (dBm) Rejection Ratio (dB) Maximum Rejection Ratio Limit (dB) No signal found in scanning across complete receiver range from both ANT1 and ANT2, -35 dBm input 5.8.3.2. FM Mode EUTs Scanning Frequency Band (MHz) Cellular Transmitter Test Frequencies (MHz) RF Input Signal Level Cellular Frequencies for 12 dB SINAD (dBm) Reference Sensitivity (dBm) Rejection Ratio (dB) Maximum Rejection Ratio Limit (dB) No signal found in scanning across complete receiver range from both ANT1 and ANT2, -35 dBm input 5.8.3.3. CW Mode EUTs Scanning Frequency Band (MHz) Cellular Transmitter Test Frequencies (MHz) RF Input Signal Level Cellular Frequencies for 12 dB SINAD (dBm) Reference Sensitivity (dBm) Rejection Ratio (dB) Maximum Rejection Ratio Limit (dB) No signal found in scanning across complete receiver range from both ANT1 and ANT2, -35 dBm input 5.8.3.4. SSB Mode EUTs Scanning Frequency Band (MHz) Cellular Transmitter Test Frequencies (MHz) RF Input Signal Level Cellular Frequencies for 12 dB SINAD (dBm) Reference Sensitivity (dBm) Rejection Ratio (dB) Maximum Rejection Ratio Limit (dB) No signal found in scanning across complete receiver range from both ANT1 and ANT2, -35 dBm input 5.8.3.5. RTTY Mode EUTs Scanning Frequency Band (MHz) Cellular Transmitter Test Frequencies (MHz) RF Input Signal Level Cellular Frequencies for 12 dB SINAD (dBm) Reference Sensitivity (dBm) Rejection Ratio (dB) Maximum Rejection Ratio Limit (dB) No signal found in scanning across complete receiver range from both ANT1 and ANT2, -35 dBm input FCC PARTS 15 SUBPART B Section 15.121 Page 29 HF/50 MHz Transceiver, M/N: IC-7410 FCC ID: AFJ318200 ULTRATECH GROUP OF LABS File #: ICOM-263F15B121 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 December 10, 2010 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vicultratech-, Website: http:/www.ultratech- All tes

    注意事项

    本文(IC-7410_FCC_test_report_2010.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开