    Ranger_RCI-6300FHP_FTB_align.pdf

    • 资源ID:198191       资源大小:148.97KB        全文页数:5页
    • 资源格式: PDF        下载积分:6积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Ranger_RCI-6300FHP_FTB_align.pdf

    TECHNICAL SUPPORT Alignment Procedures RCI-6300 - FHP & FTB PLL Alignment - Transmitter Alignment - Receiver Alignment Equipment required for Alignment procedure: DC Power Supply ( 13.8 Vdc, 20A ) RF Wattmetter ( 2560 MHz, 100W ) Digital voltmeter or Multimeter. Automatic Modulation Meter. Audio Signal Generator Digital voltmeter or Multimeter. Frequency Counter - 100 MHz RF Signal Generator - 100 MHz Automatic Distortion Meter Oscilloscope (50 MHz), with X10 probe SINAD Meter 50 dummy load To view proper test equipment setup for both the receiver and transmitter portion of the alignment procedures, please see this drawing - 6300 Setup. After viewing, press back to return to this page. To view Main PCB Adjustment Location of adjustment points, please see this drawing - 6300 Main PCB. After viewing, press back to return to this page. The following steps are required to re-align the RCI-6300. Caution: Alignment should only be attempted by personnel trained in RF product testing and alignment. 6300 PLL Synthesizer Alignment: 1. VCO Voltage: Disconnect the short PCB from TP7, TP8, and TP9. Set radio to Fr Pool 6, CH 40 AM RX mode, set the +10KHz switch to OFF position, connect multimeter to TP2, connect oscilloscope to TP3. Adjust L14 for 6.5 Vdc 0.1. Adjust L15 for maximum output and balance ( CH1 & CH40 ). 2. AM Frequency: Set radio to Fr Pool 1, CH 1 AM RX mode, Set radio to Pool 6, CH 40 AM RX mode, connect frequency counter to TP3. Adjust L20 to 17.5500 MHz 20Hz. Adjust L17 to 18.9600 MHz 20Hz. 3. TX Frequency: Set radio to Fr Pool 1, CH 1 AM TX mode, connect frequency counter to TP3. Adjust VR7 to 17.5500 MHz 20Hz. 4. AM OSC: Set radio to Fr Pool 1, CH 1 AM TX mode, connect frequency counter to TP5. Adjust L23 to 10.6950 MHz 20Hz. This completes the PLL alignment procedure. 6300 Transmitter Alignment: 1. TX Power: Set radio to Fr Pool 2, CH 19 AM TX mode, connect the short PCB to TP7, TP8, and TP9, connect RF power meter to antenna jack, Set RF power fully clockwise. Adjust L40, L42, L43 power MAX. Adjust L44 for minimum spurious emission. Adjust L40, L42 to balance power between CH1 and CH 40. 2. AM TX Power: Set radio to Fr Pool 2, CH 19 AM TX mode, modulation off. Adjust VR14 for 10W on the RCI-6300F HP or 50W on the RCI-6300F TB. 3. RF Power Meter: Set radio to Fr Pool 2, CH 19 AM TX mode, set SWR/S-RF switch to S/RF position, set modulation OFF. Adjust VR9 until RF Power Meter is in-between the green and red bar on PWR scale. 4. AM Modulation: Set radio to Fr Pool 2, CH 19 AM TX mode, set Mic gain fully clockwise, AF signal 30 mV, 1 KHz to microphone. Adjust VR16 for 90%. 5. FM Deviation: Set radio to Fr Pool 2, CH 19 FM TX mode, set Mic gain fully clockwise, AF signal 30 mV, 1 KHz to microphone. Adjust VR5 for 4KHz. 6. Frequency Counter Adjust: Set radio to Fr Pool 2, CH 19 AM TX mode, set DIM/BRT switch to BRT. Adjust VC1 on frequency counter for 28.9150 MHz. This completes the Transmitter stage of the alignment procedure. 6300 Receiver Alignment: 1. AM Sensitivity: Set radio to Fr Pool 2, CH 19 AM RX mode, RF gain fully clockwise, SQ fully counter clockwise, VOL control at 2 oclock, NB-ANL/OFF switch to OFF, connect RF SG to antenna jack, ( Frequency 28.915 MHz, 1 V. Mod 30% ) Adjust L2, 3, 5, 6, 7, 8, 9, 10 for Audio Output 2V S/N 10db. Set radio to Pool 6, CH 40 AM mode, RF SG setting to 29.655 MHZ. Adjust L5, L6 for balance between CH 1 and CH 40. Set radio to Pool 1, CH 1 AM mode, RF SG setting to 28.245 MHZ. Adjust L5, L6 for balance between CH 1 and CH 40. 2. FM Sensitivity: Set radio to Fr Pool 2, CH 19 FM RX mode, mode switch to FM, RF SG setting 28.915 MHz 0.5V, mod 3KHz. Adjust L4 for audio output max, S/N 20db. 3. NB Adjust: Set radio to Fr Pool 2, CH 19 AM RX mode, RF SG setting 28.915 MHz 100 V, mod OFF, NB-ANL/OFF switch to NB/ANL position, connect voltmeter to TP1. Adjust L1 for DC Voltage to max ( 2.0V ). 4. AM Squelch: Set radio to Fr Pool 2, CH 19 AM RX mode, SQ control fully clockwise, RF SG setting 28.915 MHz 1 mV, mod 30% Adjust VR4 very slowly until squelch just opens. 5. AM S/RF Meter: Set radio to Fr Pool 2, CH 19 AM RX mode, SWR/S-RF switch to S/RF position, RF SG setting 28.915 MHz 100 V, mod 30%. Adjust VR1 so that meter needle goes to S9 on the S scale. This completes the Receiver stage of the alignment procedure _ . The following steps are required to re-align the RCI-6300. Caution: Alignment should only be attempted by personnel trained in RF product testing and alignment. To view Main PCB Adjustment Location of adjustment points, please see the following drawing - 6300 Main PCB. After viewing, press back to return to this page. To view proper test equipment setup for both the receiver and transmitter portion of the alignment procedures, please see this drawing - 6300 Setup. After viewing, press back to return to this page Radio Mods Database

    注意事项

    本文(Ranger_RCI-6300FHP_FTB_align.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开