欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    Biddle 210170_UG 电路图.pdf

    • 资源ID:199763       资源大小:288.93KB        全文页数:6页
    • 资源格式: PDF        下载积分:6积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Biddle 210170_UG 电路图.pdf

    MEGGER210170 Insulation clean, and with no broken or cracked insulation. Replacement fuses must be of the correct size, type and rating. Symbols used on the instrument Caution: risk of electric shock Caution: refer to accompanying notes Equipment protected throughout by Double Insulation (Class II) NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. RadioFans.CN 收音机爱 好者资料库 OPERATION Default Voltage measurement The 210170 will act as a default voltmeter (0 to 600 V a.c.) with any of the Insulation test positions selected. The Test push must not be pressed when making a voltage test. Note:- The 210170 is internally fuse protected to 500 V. For fuse protection with supplies above 500 V, use Fuse Probe Kit FPK5. 1.Select any Insulation test position with the rotary selector switch. 2.Carefully connect the test leads to the circuit under test. Do not press the Test push. 3.Read the voltage measurement from the voltmeter scale. 4.Carefully disconnect the test leads. Low Resistance measurement () 1.Select with the rotary selector switch. 2.Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 3.Any pointer deflection indicates a live circuit, and testing should be aborted. 4.Press the Test push, and keep it pressed while turning the generator handle. 5.Read the measurement from the k scale. 6.Disconnect the test leads. Insulation Testing (M) Automatic circuit discharge is effective when the test button is released, and decaying voltage is indicated by the scale needle until the circuit is discharged. 1.Select M with the rotary selector switch. 2.Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 3.Any pointer deflection indicates a live circuit, and testing should be aborted. 4.Press the Test button, and keep it pressed while turning the generator handle. 5.Read the measurement from the M scale. 6.Release the Test push and monitor any scale needle movement to confirm when any discharging voltage decays to zero. 7.When the circuit has discharged, disconnect the test leads. Refer to Safety Warnings before using the instrument MEASUREMENT SCALES RadioFans.CN 收音机爱 好者资料库 Using the Guard Terminal For basic insulation tests and where there is little possibility of surface leakage affecting the measurement, it is unnecessary to use the guard terminal. In cable testing, there may be surface leakage paths across the insulation between the bare cable and the external sheathing due to the presence of moisture or dirt. Where it is required to remove the effect of this leakage, particularly at high testing voltages, a bare wire may be bound tightly around the insulation and connected via the third test lead to the guard terminal G. The guard terminal is at the same potential as the negative terminal. Since the leakage resistance is effectively in parallel with the resistance to be measured, the use of the guard causes the current flowing through surface leakage to be diverted from the measuring circuit. The instrument therefore reads the leakage of the insulator, ignoring leakage across its surface. SPECIFICATION Insulation Ranges Measuring Ranges:0 - 20,000 M at all test voltages Test Voltages (d.c.):100 V; 250 V; 500 V; 1kV on open circuit Test V. Accuracy:5% Short Cct. Current:220 A nominal on all ranges Accuracy:3% of scale length on a 3.08 inch arc length Low resistance Range Measuring Range:0 - 5000 Open Cct. Voltage:3 V 5% Short Cct. Current:30 mA 10% Accuracy:3% of scale length on a 3.08 inch arc length Default Voltage measurement Range:0 - 600 V a.c. Accuracy:2.5% of scale length General Specifications Overload rating:The 210170 is protected for connection to Power distribution systems up to 300 V Line - Ground, and 500 V Line - Line for Installation Category III*. Terminal Characteristics Leakage path to +ve terminal to G terminal to -ve terminal Tightly bound bare wire RadioFans.CN 收音机爱 好者资料库 AVO INTERNATIONAL Archcliffe Road Dover Kent CT17 9ENTel: +44 (0) 1304 502100 EnglandFax: +44 (0) 1304 207342 PO Box 9007 Valley Forge PA 19484-9007Tel: +1 (610) 676-8500 U.S.A.Fax: +1 (610) 676-8610 4271 Bronze Way Dallas TX 75237-1017Tel: +1 (800) 723-2861 (U.S.A. only) U.S.A.Tel: +1 (214) 330-3203 (International) Fax: +1 (214) 337-3038 MEGGER SARL 29 Alle de Villemomble, 93340 Le Raincy ParisTel: +33 (1) 43.02.37.54 FranceFax: +33 (1) 43.02.16.24 This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice. MEGGER is the registered Trade Mark of AVO INTERNATIONAL LIMITED. Copyright , AVO INTERNATIONAL LIMITED. Part No. 6172-382 - Edition 3 - Printed in England - 11GG Temp. Range: Operating: 14F to 122F Storage:4F to 158F Humidity: Operating: 70% RH at 68F, 50% RH at 104F Storage:95% RH at 95F Automatic Discharge: Capacitive circuits are automatically discharged when the Test push is released following an insulation test. Power Supply:Low voltage brushless a.c. generator Fuses:2 x 500 mA (F) 500 V H.B.C. 10 kA min 114“ x 14“ To check these fuses, short all three test leads together and set the rotary selector switch on any Insulation test position. Press the Test push and keep it pressed while turning the generator handle. The needle should register approximately 2 M. A zero reading indicates that the G fuse has ruptured. An Infinity reading indicates that the +ve fuse has ruptured. Fuse Replacement: Held in a screw type holder located in the base of the instrument. Use a flat blade screwdriver to release the center part of the holder, and remove the ruptured fuse. Replace with fuse(s) of the correct type, size and rating. Weight:2.2 lb Dimensions:814” (including generator handle) x 5” x 5” Cleaning:Wipe disconnected instrument with a clean cloth dampened with soapy water or Isopropyl Alcohol IPA) *Relates to transient overvoltage likely to be found in fixed installation wiring. ACCESSORIES SuppliedPart Number User Guide6172-382 Test lead set comprising:- 1 black, 1 red, 1 green test lead, with alligator clips 6220-436 Test Record Card (5 supplied)210949 Optional Carrying case 217740 Fuses (500mA) x 5 6121-289 Fused probe kit FPK56111-288 Black test lead with large alligator clip6220-295 Red test lead with large alligator clip6220-586 Green test lead with large alligator clip6220-587 Test Record cards (Pack of 20)6111-216 Publication - A Stitch in TimeAVTM21-P8B 0.5A(F) 500V HBC(10 kA) Guard fusePositive fuse REPAIR AND WARRANTY The instrument contains static sensitive devices, and care must be taken in handling the printed circuit board. If an instruments protection has been impaired it should not be used, but sent for repair by suitably trained and qualified personnel. The protection is likely to be impaired if for example; it shows visible damage; fails to perform the intended measurements; has been subjected to prolonged storage under unfavourable conditions, or has been subjected to severe transport stresses. NEW INSTRUMENTS ARE GUARANTEED FOR 1 YEAR FROM THE DATE OF PURCHASE BY THE USER. Note: Any unauthorized prior repair or adjustment will automatically invalidate the Warranty. INSTRUMENT REPAIR AND SPARE PARTS For service requirements for MEGGERInstruments contact :- AVO INTERNATIONALorAVO INTERNATIONAL Valley Forge Corporate CenterArchcliffe Road 2621 Van Buren AvenueDover Norristown, PA 19403Kent, CT17 9EN U.S.A.England Tel: +1 (610) 676-8579Tel: +44 (0) 1304 502243 Fax: +1 (610) 676-8625 Fax: +44 (0) 1304 207342 or an approved repair company. Approved Repair Companies. A number of independent instrument repair companies have been authorised for repair work on most MEGGERinstruments, using genuine MEGGER spare parts. Consult the Appointed Distributor / Agent regarding spare parts, repair facilities, and advice on the best course of action to take. Returning an Instrument for Repair If returning an instrument to the manufacturer for repair, it should be sent freight pre-paid to the appropriate address. A copy of the invoice and of the packing note should be sent simultaneously by airmail to expedite clearance through Customs. A repair estimate showing freight return and other charges will be submitted to the sender, if required, before work on the instrument commences.

    注意事项

    本文(Biddle 210170_UG 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开