欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    EMCO 3850-2 Instruction Manual 电路图.pdf

    • 资源ID:199903       资源大小:606.63KB        全文页数:19页
    • 资源格式: PDF        下载积分:8积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    EMCO 3850-2 Instruction Manual 电路图.pdf

    Model 3850/2 Line Impedance Stabilization Network (LISN) User Manual RadioFans.CN 收音机爱 好者资料库 ii | ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall constitute ETS-Lindgren L.P. assuming any liability whatsoever arising out of the application or use of any product or circuit described herein. ETS-Lindgren L.P. does not convey any license under its patent rights or the rights of others. Copyright 19962009 by ETS-Lindgren L.P. All Rights Reserved. No part of this document may be copied by any means without written permission from ETS-Lindgren L.P. Trademarks used in this document: The ETS-Lindgren logo is a trademark of ETS-Lindgren L.P. Revision Record | MANUAL 3850/2 | Part #399139, Rev. E Revision Description Date AC Initial Release; updates December, 1996 D Rebrand October, 2008 E Added product photos February, 2009 RadioFans.CN 收音机爱 好者资料库 | iii Table of Contents Notes, Cautions, and Warnings . v 1.0 Introduction . 7 ETS-Lindgren Product Information Bulletin . 7 2.0 Maintenance . 9 Service Procedures . 9 3.0 Specifications . 11 Electrical Specifications . 11 Physical Specifications . 11 4.0 Installation . 13 Power . 14 Equipment Under Test . 16 Spectrum Analyzer / Receiver . 17 Appendix A: Warranty . 19 RadioFans.CN 收音机爱 好者资料库 iv | This page intentionally left blank. | v Notes, Cautions, and Warnings Note: Denotes helpful information intended to provide tips for better use of the product. Caution: Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures. Warning: Denotes a hazard. Failure to follow instructions could result in SEVERE personal injury and/or property damage. Included text gives proper procedures. See the ETS-Lindgren Product Information Bulletin for safety, regulatory, and other product marking information. vi | This page intentionally left blank. Introduction | 7 1.0 Introduction The ETS-Lindgren Model 3850/2 Line Impedance Stabilization Network (LISN) is a two-channel low pass filter network used for conducted emissions measurement. The Model 3850/2 is designed to isolate the equipment under test from an external power source while steering any radio frequency signals from the power line to a 50-ohm port. The conducted emissions measurements may be made in accordance with regulatory compliance standards. ETS-Lindgren Product Information Bulletin See the ETS-Lindgren Product Information Bulletin included with your shipment for the following: Warranty information Safety, regulatory, and other product marking information Steps to receive your shipment Steps to return a component for service ETS-Lindgren calibration service ETS-Lindgren contact information 8 | Introduction This page intentionally left blank. Maintenance | 9 2.0 Maintenance Before performing any maintenance, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. Maintenance of the Model 3850/2 is limited to external components such as cables or connectors. Clean the exterior of the cabinet using a damp cloth and mild cleaner. Always unplug the unit before cleaning. To prevent electrical shock, do not remove cover. If you have any questions concerning maintenance, contact ETS-Lindgren Customer Service. Service Procedures For the steps to return a system or system component to ETS-Lindgren for service, see the Product Information Bulletin included with your shipment. 10 | Maintenance This page intentionally left blank. Specifications | 11 3.0 Specifications Electrical Specifications Frequency Range: 9 kHz 100 MHz (VDE 0876 specified curve 20% Lines Plus Ground: 2 Network Inductance: 50 H / 250 H Network Impedance: 50 Current Rating: 50 Amperes Maximum AC Voltage: 250 VAC line-to-ground 440 VAC line-to-line Input Connectors: 50 Amperes Output Connectors: 50 Amperes Monitor Port: BNC 1 per line Environmental Installation: Indoor use only Altitude: 15000 ft (4572 m) max Temperature: 0C to 40C (32F to 104F) Relative Humidity: 80% up to 31C (87.8F) decreasing linearly to 50% at 40C (104F) Physical Specifications Height: 34.9 mm (13.7 in) Width: 51.4 mm (20.2 in) Depth: 57.1 mm (22.5 in) Weight: 20.4 kg (44.97 lb) 12 | Specifications This page intentionally left blank. Installation | 13 4.0 Installation Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. Overcurrent protection is not provided in the Model 3850/2. The unit must be connected to a power mains with properly rated mains protection. The Model 3850/2 is provided with a protective earthing connection. The unit should only be connected to a mains source which utilizes a protective earth conductor. Due to the high leakage current to ground inherent in this type of equipment, it is necessary to properly connect the Model 3850/2 to an appropriate earthing point on the power mains prior to energizing. This earthing point should be determined by an electrician authorized to perform such work by appropriate code or law. Any interruption of the protective conductor inside or outside of the unit is likely to make the Model 3850/2 dangerous. Intentional interruption is prohibited. The Model 3850/2 is provided with resistors to help bleed off high voltage transients, but it is advisable to connect the input and output connectors to their proper power lines and loads before connecting the monitor port to the measurement instrumentation; otherwise, power surges or transients can damage the test instrumentation mixers or attenuators. 14 | Installation Power Model 3850/2 Back Panel The Model 3850/2 Line Impedance Stabilization Network (LISN) is nominally designed for a 50-ampere current capacity. Maximum line-to-line voltage must not exceed the voltage rating of the power connectors provided on the input and output of the unit. See Specifications on page 11 for the applicable maximum value. Installation | 15 The input power connection to the line side of the Model 3850/2 is made through the red and black pin receptacles labeled L1 and L2 on the back panel. Power to the Model 3850/2 should be through a properly rated circuit breaker and/or a switch which can remove power from the unit in case of emergency. This device should be installed near the Model 3850/2. The green pin receptacle and the brass lug terminal are both connected to chassis ground. Prior to energizing the Model 3850/2, the earth connection from the power mains must be connected to the green pin receptacle. The brass lug terminal should be bonded to the ground plane of the conducted emissions test setup. This line does not provide high frequency isolation and should not carry any voltage above earth potential. 16 | Installation Equipment Under Test Model 3850/2 Front Panel The Equipment Under Test (EUT) is connected to the Model 3850/2 through the red and black socket receptacles located on the front panel. The ground connection to the EUT is made through the green socket receptacle. In normal operation, the radio frequency bonding stud on the front panel should be connected to the ground plane of the conducted emissions test setup by a grounding strap or braid. Installation | 17 Spectrum Analyzer / Receiver Use the BNC connectors on the front panel to connect the spectrum analyzer or EMI receiver. See page 16 for a view of the front panel connectors. The monitor port which is not being monitored should be terminated into a coaxial 50-ohm terminator. Connect the input and output terminals to their proper mains connections and EUT connections before connecting the monitor port to the measurement instrumentation; otherwise, power surges may damage the test instrumentation mixers or attenuators. Removal of a terminator and connection to the BNC receptacle will not generate power surges. When the power is to be disconnected, remove the coaxial connection to the measurement instrumentation first to avoid possible damage. 18 | Installation This page intentionally left blank. Warranty | 19 Appendix A: Warranty See the Product Information Bulletin included with your shipment for the complete ETS-Lindgren warranty for your Model 3850/2 Line Impedance Stabilization Network (LISN). DURATION OF WARRANTIES FOR MODEL 3850/2 All product warranties, except the warranty of title, and all remedies for warranty failures are limited to two years. Product Warranted Duration of Warranty Period Model 3850/2 Line Impedance Stabilization Network (LISN) 2 Years

    注意事项

    本文(EMCO 3850-2 Instruction Manual 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开