    Biddle CFL535E_manual 电路图.pdf

    • 资源ID:200434       资源大小:336.26KB        全文页数:16页
    • 资源格式: PDF        下载积分:8积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Biddle CFL535E_manual 电路图.pdf

    User Guide MEGGER Time Domain Reflectometer MEGGER CFL535E - TDR2000 RadioFans.CN 收音机爱 好者资料库 Safety Warnings3 Introduction4 Features and Controls6 Operation8 Instrument Features9 Balance Control9 Velocity Factor9 Pulse Widths9 Memory Features10 Configuration Menu11 Techniques to Improve Accuracy13 Care and Maintenance13 Specification14 Repair and Warranty16 MeterCenter (800) 230-6008 www.MeterC Caution: Refer to accompanying notes. Equipment protected throughout by double or reinforced insulation Instrument flash tested to 3.7kV r.m.s. for 1 min. Equipment complies with current EU directives Symbols used on the instrument are: Contents RadioFans.CN 收音机爱 好者资料库 3 SAFETY WARNINGS #This instrument meets the safety requirements of IEC 61010 part 1 to 150V cat III. If it is to be used in situations where hazardous live voltages may be encountered then an additional blocking filter must be used. #CAUTION (Risk of electric shock) #Although this tester does not generate any hazardous voltages, circuits to which it can be connected could be dangerous due to electric shock hazard or due to arcing (initiated by short circuit). While every effort has been made by the manufacturer to reduce the hazard, the user must assume responsibility for ensuring his or her own safety. #The instrument should not be used if any part of it is damaged. #Test leads, probes and crocodile clips must be in good order, clean and with no broken or cracked insulation. #Check that all lead connections are correct before making a test. #Disconnect the test leads before accessing the battery compartment. #Refer to operating instructions for further explanation and precautions. #Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS RadioFans.CN 收音机爱 好者资料库 Thank you for purchasing this quality AVO product. Before using your new instrument please take the time to read this user guide, ultimately this will save you time, advise you of any precautions you need to take and could prevent damage to yourself and the instrument. Your TDR2000 is a very advanced instrument capable of identifying a wide range of cable faults. The instrument uses a technique called Time Domain Reflectometry (TDR) which in many ways is similar to radar. Narrow pulses of electrical energy are transmitted along a pair of conductors in a cable. The pulse travels through the cable at a velocity determined by the insulation between the conductors and the resistance to the flow of the pulse is characterised as impedance for the cable. Changes in cable impedance will cause a proportion of the pulse to be reflected. The pulse velocity is normally described as a fraction of the speed of light and is called the Velocity Factor. By measuring the time between the transmitted pulse and the reception of the reflected pulse, and multiplying this by the speed of light and the velocity factor, the actual distance to the reflection point can be given. Faulty cables, poor joints or discontinuities will all cause a change in impedance. Impedances higher than the cables cause a normal reflection. Impedances lower than the cables cause an inverse reflection. Matched terminations absorb all the pulse hence no reflection will occur, the cable appearing endless. Open or Short circuits will reflect all the pulse energy and the TDR will not see the cable beyond that fault. As a pulse is transmitted down a cable, the size and shape of that pulse is gradually attenuated by losses in the cable: the pulse gets smaller in height and more spread out. The level of attenuation is determined by the cable type, the condition of the cable and any connections along its length. The limit of how far you can see is determined by the point beyond which you will not discern a reflection. To maximise the instruments range, the TDR2000 has an adjustable gain setting on its input that can apply up to 90dB of gain to the reflected signal to allow you to discern a reflection from farther away. By combining this variable gain with increasing pulse widths, the TDR2000 can discern faults up to 16Km away. The MEGGER TDR2000 can be used on any cable consisting of at least two insulated metallic elements, one of which may be the armouring or screen of the cable. The balancing circuit, which is described in the Operating Instructions, can balance for any cable with a characteristic impedance of 0-120. Dual inputs and the large graphic display allow a wide range of comparative tests to be performed between cable pairs or stored results. The instrument has 15 trace memories, enabling previous test results to be displayed and compared with “live” results. This allows the gradual ageing of a cable to be monitored or characteristic changes to be detected between periodic tests, for example if the cable has suffered water ingress or has been tapped and split. Introduction 4 There are four modes of operation to get “live” results, and these are: L1 it shows visible damage; fails to perform the intended measurements; has been subjected to prolonged storage under unfavourable conditions, or has been subjected to severe transport stresses. NEW INSTRUMENTS ARE GUARANTEED FOR 3 YEARS FROM THE DATE OF PURCHASE BY THE USER. NOTE: Any unauthorized prior repair or adjustment will automatically invalidate the Warranty. INSTRUMENT REPAIR AND SPARE PARTS For service requirements for MEGGER Instruments contact: AVO INTERNATIONAL or AVO INTERNATIONAL Archcliffe Road Valley Forge Corporate Centre Dover 2621 Van Buren Avenue Kent, CT17 9EN.Norristown, PA 19403 England.U.S.A. Tel: +44 (0) 1304 502243Tel: +1 (610) 676-8579 Fax: +44 (0) 1304 207342 Fax: +1 (610) 643-8625 For sales Contact: MeterCenter (800) 230-6008 www.MeterC Approved Repair Companies A number of independent instrument repair companies have been authorised for repair work on most MEGGER instruments, using genuine MEGGER spare parts. Consult the Appointed Distributor/Agent regarding spare parts, repair facilities, and advice on the best course of action to take. Returning an Instrument for Repair If returning an instrument to the manufacturer for repair, it should be sent freight pre-paid to the appropriate address. A copy of the invoice and of the packing note should be sent simultaneously by airmail to expedite clearance through Customs. A repair estimate showing freight return and other charges will be submitted to the sender, if required, before work on the instrument commences. Repair and Warranty 16

    注意事项

    本文(Biddle CFL535E_manual 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开