欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    1659 电路图.pdf

    • 资源ID:201432       资源大小:293.03KB        全文页数:2页
    • 资源格式: PDF        下载积分:6积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    1659 电路图.pdf

    534 Main Street, Westbury, NY 11590 IET LABS, INC. in the GenRad T TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 Contents p. 2 Applic. pp. 4-8 Selection pp. 9-11 Products pp. 12-87 GenRad prod ucts pp. 50-87 Index p. 89 9 1659 Digibridge RLC Testers 1659 Digibridge RLC Testers p. 1 of 2 Digibridges The GenRad 1659 Digibridge RLC Tester is an easily programmable, microprocessor-based high performance passive component tester. It automatically identifies the type of component under test and measures in the prop- er range. The result is simple, precise, unambiguous RLC component testing. The 1659 RLC Digibridge is an instrument for measuring primary parameters of inductance (L), capacitance (C) and resistance (R) and secondary parameters of dissipation factor (D) and quality factor (Q). QuadTech designed this single compact unit with maximum flexibility and operator convenience in mind. The simple front panel design of the Digibridge requires less effort to operate. Digital display and user friendly control allows test parameters and limits to be set easily. Programmable test limits and automatic binning give the 1659 its remarkable capability. Programming test limits is as simple as pushing a few buttons in an easily understood sequence. Once set, the operator works in an automatic binning mode designed to replace guesswork with consistent throughput. The GenRad1659 is ideal for incoming inspection because it satisfies a wide range of testing requirements. FEATURES: Easy to Use Accuracy of 0.1% for RLC measurements Four test frequencies of 100Hz, 120Hz, lkHz and 10kHz A choice of three test speeds: 2,4, or 8 measurements per second to complement automatic handling equipment and maximize throughput. A choice of two measurement modes: Continuous or Triggered (single measurement or average of 10) ensures measurement flexibility. A full, five-digit LED display for RLC measurements and a four-digit readout for D and Q testing, simultaneously display both test results for each measurement, automatically. A built-in test fixture for fast setup and ease-of-use when testing axial and radial lead components. Guarded Kelvin measurement techniques protect measurement integrity. Automatic self-test and diagnostic check maintains reliable, error-free operation. Automatic limit comparison and binning ensure fast, mistake-proof sorting of components. Optional IEEE-488 Bus and Handler Interface enable remote programming and allow the addition of a component handler to optimize throughput. RadioFans.CN 收音机爱 好者资料库 534 Main Street, Westbury, NY 11590 IET LABS, INC. in the GenRad T TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 Contents p. 2 Applic. pp. 4-8 Selection pp. 9-11 Products pp. 12-87 GenRad prod ucts pp. 50-87 Index p. 89 10 1659 Digibridge RLC Testers 1659 Digibridge RLC Testers p. 2 of 2 Digibridges 1659 Digibridge RLC Features Measurement Parameters: R/Q, L/Q, C/R, C/D (series or parallel) Test Frequencies: 100Hz, 120Hz, lkHz,and 10kHz. Accuracy 0.01%. Applied Voltage: 0.3V rmsV maximum Measurement Speed: 2, 4 or 8 measurements/second for Slow, Medium or Fast. Measurement Mode: Continuous, Triggered (single, or 1 to 10 measurements averaged). Display Format: Dual Display featuring 5 full digit LED for RLC and 4 full digit LED for DQ Bin Number,Value Automatically positioned decimal points and minus signs where appropriate. Individual LED indicators for parameters, units, and measurement conditions. GO/NO GO lights Bias: Internal 2.0VDC External up to 60VDC Automatic Functions: Auto ranging with manual hold Auto parameter (RLC) with manual selection Binning: Eight pass bins for RLC Two fail bins, RLC and DQ Interfaces: IEEE-488/Handler Interface option Ranges: Parameter RLC DQ R/Q 0.00001 to 99999M 0.0001 to 9999 L/Q 0.00001mH to 99999H 0.0001 to 9999 C/D 0.00001pF to 99999mF 0.0001 to 9999 Accuracy: Basic RLC 0.1%. Basic DQ 0.0005 Zeroing: Open and short circuit compensation. General Features: Charged Capacitor Protection (1 Joule) Keyboard Lock Store Test Conditions Dimensions: (w x h x d): 14.8 x 4.4 x 13.5in (375 x 112 x 343mm) Weight: 10 lbs. (4.5kg) net, 15 lbs. (6.8kg) shipping. Accessories Supplied: Power Cable Axial Lead Adapters Test Fixture (Built-in) Instruction Manual Enviromental: Operating: 0C to +50C Storage: -40C to +75C Humidity: <85% Power: 90 - 250V AC 50 or 60 Hz 60W max Digibridge 1659 RLC Tester Includes: QuadTech P/N Item 4200-0300 AC Power Cord 1657-5995 Axial Lead Adaptors 1659-0120 Instruction Manual No P/N Calibration Certificate Traceable to NIST Optional Accessories: No P/N Calibration Data 1658-9620 IEEE/Handler Interface 1689-9601 BNC Adapter Box 1689-9602 BNC to BNC Extender Cable 1657-9600 Banana/Alligator Clip Extender Cable 1689-9604 Calibration Kit 7000-03 Kelvin Clip Extender Cable 7000-05 Chip Component Tweezers 1689-9600 Remote Test Fixture 1689-9605 GO/NO GO Remote Test Fixture 1688-9600 874 Connector Extender Cable Ordering Information RadioFans.CN 收音机爱 好者资料库

    注意事项

    本文(1659 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开