欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    krohnhite 3905C Manual 电路图.pdf

    • 资源ID:202985       资源大小:505.69KB        全文页数:26页
    • 资源格式: PDF        下载积分:10积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    krohnhite 3905C Manual 电路图.pdf

    MODEL 3905C IEEE-488 PROGRAMMABLE FILTER MAINFRAME OPERATING MANUAL MAINFRAME MICROPROCESSOR SERIAL NO. _ SERIAL NO. _ Unit 4, 15 Jonathan Drive, Brockton, MA 02301-5566 Tel: (508) 580-1660; Fax: (508) 583-8989 E-mail: infokrohn-; Web: www.krohn- RadioFans.CN 收音机爱 好者资料库 Model 3905C Table of Contents TABLE OF CONTENTS 1.0 GENERAL DESCIPTION. 1-1 1.1 INTRODUCTION . 1-1 1.2 SPECIFICATIONS. 1-1 2.0 OPERATION. 2-1 2.1 INTRODUCTION . 2-1 2.2 TURN-ON PROCEDURE. 2-1 2.3 SELF-TEST. 2-1 2.4 FRONT PANEL CONTROLS AND DISPLAYS. 2-2 2.4.1 Data Keys and Display . 2-2 2.4.2 Control Keys . 2-2 2.4.3 Input Gain Keys and Display . 2-4 2.4.4 Output Gain Keys and Display . 2-4 2.4.5 Channel Keys and Display . 2-4 2.4.6 Clear Entry Key (CE) . 2-4 2.4.7 LED Indicators . 2-5 2.4.8 Connectors (BNC) . 2-5 2.4.9 Switch. 2-5 2.5 REAR PANEL . 2-5 2.5.1 Introduction . 2-5 2.5.2 Connectors (BNC) . 2-5 2.5.3 Power. 2-5 2.5.4 Connector (Remote) . 2-6 3.0 IEEE-488 STD (GPIB) PROGRAMMING . 3-1 3.1 INTRODUCTION . 3-1 3.2 PRELIMINARY PROGRAMMING INFORMATION . 3-1 3.2.1 GPIB Primary Bus Address . 3-1 3.2.2 IEEE-488 Bus Interface Programming Connector . 3-2 3.3 ASCII DATA COMMANDS . 3-2 3.3.1 Format. 3-2 3.3.2 Types of Data Commands. 3-2 3.3.3 Table of ASCII Commands. 3-3 3.3.4 Examples . 3-4 3.4 IEEE-488 STANDARD COMMANDS. 3-5 3.4.1 Multi-line Messages. 3-6 3.4.2 Polling Commands. 3-7 3.4.3 Uniline Messages . 3-9 3.5 TALKER FORMAT. 3-9 3.5.1 Parameter Information Format . 3-10 3.5.2 Overload Status Information Format . 3-10 3.5.3 Model Number and Software Version Format. 3-10 3.5.4 Board Model Number Format. 3-11 4.0 INCOMING ACCEPTANCE . 4-1 4.1 INTRODUCTION . 4-1 i RadioFans.CN 收音机爱 好者资料库 Model 3905C Table of Contents ii RadioFans.CN 收音机爱 好者资料库 Table of Contents Model 3905C Model 3905C IEEE-488 Programmable Filter Mainframe iii Model 3905C Section 1 General Description SECTION 1 GENERAL DESCRIPTION 1.1 INTRODUCTION The Model 3905C Mainframe is used in conjunction with the Krohn-Hite plug-in modules, that are operational only when inserted in the five module Model 3905C Mainframe. The Mainframe includes a Model 39A-05 microprocessor plug-in module. The modules are easily accessible from the rear of the Mainframe. The Mainframe provides local/IEEE-488 programming, indicators for the input and output gain, cutoff frequency setting, channel selection and overload detection. Non-volatile, battery-backed, CMOS memory permits storing and recalling of 85 selectable groups. Storing and recalling group settings is accomplished with only one command. Self-testing of the digital circuitry occurs upon power-up. This Operating and Maintenance Manual is for the Model 3950A and its Model 39A-05 microprocessor module only. Separate manuals are provided for each type of module. 1.2 SPECIFICATIONS 1.2.1 CAPACITY: 5 modules. 1.2.2 MEMORY: 85 selectable groups; each group has storage for 5 module set-ups. Memory is non-volatile battery-backed CMOS. 1.2.3 OVERLOAD MODES: Three selectable modes; non-latching, that monitors all channels and displays first channel to overload; latching that maintains overload display until cleared and no indication (used with some models). 1.2.4 OVERLOAD INDICATORS: LEDs for input and output. Gain display flashes when overload occurs on displayed channel (used with some models). 1.2.5 SELF-TEST DIAGNOSTICS: MPU checks unit upon power-up. Display indicates failure modes. 1.2.6 DISPLAYS: 7 segment green LED; 0.5” high. 1.2.7 REMOTE PROGRAMMING: IEEE-488/1978 GPIB interface. Subset: SH1, AH1, T6, L4, SR1, RL1,PP1, DC1, DT0, C0, E1. 1.2.8 OPERATING TEMPERATURE: 0 to 40C (Specifications apply at 23C 5C). 1.2.9 STORAGE TEMPERATURE: -20 to +70C. 1.2.10 POWER REQUIREMENTS: 90-132/180-264 volts ac, 50-60Hz, 20 watts. 1.2.11 DIMENSIONS: 3 ” (9cm) high, 17 ” (43.8cm) wide, 18 3/8” (50.2cm) deep. 1.2.12 WEIGHTS: 10 lbs. (4.6 kg) plus 1.75 lbs. (0.8 kg)/channel. 1.2.13 ACCESSORIES: Operating and Maintenance manual; 6 foot, 3 terminal line cord. 1.2.14 OPTIONS: Rack Mount Kit; RK-317; Module Extender; 39AME. 1.2.15 CONNECTORS: Input/Output BNC on front and rear panels. Specifications Subject To Change Without Notice. 1-1 Section 1 General Description Model 3905C This page intentionally left blank. 1-2 Model 3905C Section 2 Operation SECTION 2 OPERATION 2.1 INTRODUCTION This section describes the basic operation of the programmable multi-channel filter system consisting of the Model 3905C Mainframe, its microprocessor plug-in module and filter plug-in module(s). It includes the proper ac requirements, the recommended turn-on procedure, and a detailed explanation of all operating controls, modes of operation and special features. Implementation of the IEEE-488 standard interface bus for remote programming is explained in Section 3 of this manual. This Operating and Maintenance manual is for the Model 3905C Mainframe and its microprocessor only. Separate manuals are proved for each type of filter module. 2.2 TURN-ON PROCEDURE The Model 3905C line voltage range has been preset for either 115V or 230V operation. Check fuse in fuse receptacle for correct rating. Make certain the POWER switch on the front panel is off. Plug the line cord into the Mainframe, then the ac outlet. If the Model 3905C is to be programmed remotely, connect the bus cable to the rear panel connector of the Model 39A-05 microprocessor. After reading the Self-Test feature, described next, turn on the Model 3905C. CAUTION For safety purposes, the line cord must be connected to a grounded 3 terminal ac outlet. Because of the potentially dangerous voltages within the unit, the covers should be removed by qualified personnel only when connected to an ac power source. 2.3 SELF-TEST When the unit is turned on, the microprocessor performs a Self-Test routine whereby the entire RAM and ROM operation is verified. During the test, the front panel LEDs and DISPLAYS will light sequentially. If there is a malfunction in the microprocessor, such as defective RAM or ROM, the sequence will stop and the word “bad” will appear in the DISPLAY followed by the number 1 to 3. Refer to Section 6, Maintenance, to find which ROM or RAM is defective. When the Self-Test program is complete, the Model 3905C will return to the last set-up prior to turning the unit off. The Model 3905C is now ready to be programmed for operation. 2-1 Section 2 Operation Model 3905C 2.4 FRONT PANEL CONTROLS AND DISPLAYS Figure 2.1 shows all the front panel controls and displays of the Model 3905C. Figure 2.1 Model 3905C Front Panel Controls 2.4.1 DATA KEYS and DISPLAY Data entry keyboard control 0 to 9 and . set the numeric value of the parameter selected. To enter 1.5kHz press the 1 . 5 keys and parameter keys KILO and FREQ. The cutoff frequency will be indicated in the four digit DISPLAY. 2.4.2 CONTROL KEYS 2.4.2.1 KILO Multiplies the numerical value of the keyboard entry by 103. 2.4.2.2 MEGA Multiplies the numerical value of the keyboard entry by 106. 2.4.2.3 FREQ Enters and/or displays frequency in Hertz. 2.4.2.4 TYPE Indicates the filter type in the channel displayed. “EL7” (7-pole Elliptical), “EL5” (5-pole Elliptical), “bu” (Butterworth) and “bES” (Bessel). 2.4.2.5 MODE Indicates the mode of operation in filter channel displayed, “bYP.” For bypass, “L.P.” for low-pass, “h.P.” for high-pass, “b.P.” for band-pass and “b.r.” for band-reject. 2.4.2.6 RECALL When preceded by a number it will recall the entire five module set-ups from the memory location selected. When first pressed, the DISPLAY indicates the number of the next memory location to be recalled. For example, the DISPLAY will indicate the following: “n=09”. Pressing it again will recall the set-up of all five modules from that memory location. When pressed to indicate the next memory location to be recalled only, pressing the clear entry key CE will restore the DISPLAY back to the previous setting. 2.4.2.7 ALL CHANNEL When frequency, input/output gain, type, mode or coupling are entered or changed, and the LED in the ALL CHAN key is on, the new setting will also be entered in all other filters of the same module type. 2-2 Model 3905C Section 2 Operation 2.4.2.8 SHIFT The SHIFT key in conjunction with other keys provides additional filter characteristics and permits GPIB front panel data entry. 2.4.2.8.A Store - When the SHIFT key followed by the RECALL key is pressed, the STORE FUNCTION is performed. When SHIFTRECALL is preceded by entering a number it will store the entire five module set-ups into the memory location selected. The maximum number of memory locations is 85. When SHIFTRECALL is first pressed, the DISPLAY indicates the number of the next memory location available. For example, the DISPLAY will indicate the following: “n=09”. Pressing SHIFTRECALL again will store the set-up of all modules into that memory location. If another memory location is desired enter that location on the keyboard and then press SHIFTRECALL. When SHIFTRECALL is pressed to indicate the next memory location only, pressing the clear entry key CE will restore the DISPLAY to the previous indication. 2.4.2.8.B AC/DC Coupling - Pressing the SHIFT key followed by the TYPE key will display the input coupling, indicating “AC” or “DC”, and will alternate when the two keys are pressed again. 2.4.2.8.C Input Ohms - When SHIFT key followed by input GAIN SET key are pressed, the DISPLAY will indicate the current input ohms and will step through the ohms available each time the two keys are pressed again. 2.4.2.8.D GPIB Address - When the SHIFT key followed by the MEGA key are pressed the DISPLAY will indicate the existing GPIB address setting. To select a different one, enter it in the data keys from (0) to (30) and press the SHIFT and MEGA keys (see Section 3.2.1). 2.4.2.8.E GPIB Line Termination - When the SHIFT key followed by the ALL CHAN key are pressed the DISPLAY will indicate the existing GPIB LINE TERMINATION CODE SEQUENCE. To select a different one, enter it in the data keys from (0) to (30) and press the SHIFT and ALL CHAN keys. (See Section 3.2.1). 2.4.2.8.F Software Version - When the SHIFT key followed by the KILO key are pressed the DISPLAY will indicate the software version. 2-3 Section 2 Operation Model 3905C 2.4.2.8.G Overload Mode - Some of the Krohn-Hite plug-in filter modules have three different overload modes. When the SHIFT key followed by the MODE key are pressed the DISPLAY will indicate the current overload mode. When a data key from (1) to (3) is pressed, followed by the SHIFT and MODE keys the overload mode desired can be selected. 2.4.2.8.G1 MODE 1 (DISPLAY indicates “-1-“). In mode 1 the input and output front panel overload LEDs will be off when either the input or output amplifier

    注意事项

    本文(krohnhite 3905C Manual 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开