欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    studer D950_Op_V3-5 电路图.pdf

    • 资源ID:218876       资源大小:33.11MB        全文页数:661页
    • 资源格式: PDF        下载积分:20积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    studer D950_Op_V3-5 电路图.pdf

    Studer D950 Digital Mixing System, SW V 3.3/3.4/3.5 1. Introduction 2. Getting Started 3. Desk Operation 4. Graphic Controller Operation 5. AutoTouch+ Dynamic Automation 6. System Administration 7. Configuration Tool (Option) 8. Dimensions, Basic Specifications 9. Troubleshooting absolute humidity 1.25 g/m; rate of temperature change < 0.5 C/min. These parameters are dealt with in the following paragraphs. Under these conditions the unit or system starts and works without any prob- lem. Beyond these specifi cations, possible problems are described below. Ambient Temperature Units and systems by Studer are generally designed for an ambient tempera- ture range (i.e. temperature of the incoming air) of +5 C to +40 C. When rack mounting the units, the intended air fl ow and herewith adequate cooling must be provided. The following facts must be considered: The admissible ambient temperature range for operation of the semicon- ductor components is 0 C to +70 C (commercial temperature range for operation). The air fl ow through the installation must provide that the outgoing air is always cooler than 70 C. Average heat increase of the cooling air shall be about 20 K, allowing for an additional maximum 10 K increase at the hot components. In order to dissipate 1 kW with this admissible average heat increase, an air fl ow of 2.65 m/min is required. Example: A rack dissipating P = 800 W requires an air fl ow of 0.8 * 2.65 m/min which corresponds to 2.12 m/min. If the cooling function of the installation must be monitored (e.g. for fan failure or illumination with spot lamps), the outgoing air temperature must be measured directly above the modules at several places within the rack. The trigger temperature of the sensors should be 65 C to 70 C. Frost and Dew The unsealed system parts (connector areas and semiconductor pins) allow for a minute formation of ice or frost. However, formation of dew visible to the naked eye will already lead to malfunctions. In practice, reliable opera- tion can be expected in a temperature range above 15 C, if the following general rule is considered for putting the cold system into operation: If the air within the system is cooled down, the relative humidity rises. If it reaches 100%, condensation will arise, usually in the boundary layer between the air and a cooler surface, together with formation of ice or dew at sensi- tive areas of the system (contacts, IC pins, etc.). Once internal condensation occurs, trouble-free operation cannot be guaranteed, independent of tempera- ture. Before putting into operation, the system must be checked for internal for- mation of condensation or ice. Only with a minute formation of ice, direct Appendix IX evaporation (sublimation) may be expected; otherwise the system must be heated and dried while switched off. A system without visible internal formation of ice or condensation should be heated up with its own heat dissipation, as homogeneously (and subsequently as slow) as possible; the ambient temperature should then always be lower than the one of the outgoing air. If it is absolutely necessary to operate the cold system immediately within warm ambient air, this air must be dehydrated. In such a case, the absolute humidity must be so low that the relative humidity, related to the coldest system surface, always remains below 100%. Ensure that the enclosed air is as dry as possible when powering off (i.e. before switching off in winter, aerate the room with cold, dry air, and remove humid objects such as clothes from the room). These relationships are visible from the following climatogram. For a con- trolled procedure, thermometer and hygrometer as well as a thermometer within the system will be required. Example 1: An OB-van having an internal temperature of 20 C and a relative humidity of 40% is switched off in the evening. If the temperature falls below +5 C, the relative humidity will rise to 100% (7 g/m); dew or ice will be forming. Example 2: An OB-van is heated up in the morning with air of 20 C and a relative humidity of 40%. On all parts being cooler than +5 C, dew or ice will be forming. Appendix X Appendix 2: Mains Connector Strain Relief For anchoring connectors without a mechanical lock (e.g. IEC mains connec- tors), we recommend the following arrangement: Procedure: The cable clamp shipped with your unit is auto-adhesive. For mounting please follow the rules below: The surface to be adhered to must be clean, dry, and free from grease, oil, or other contaminants. Recommended application temperature range is +20 C to +40 C. Remove the plastic protective backing from the rear side of the clamp and apply it fi rmly to the surface at the desired position. Allow as much time as possible for curing. The bond continues to develop for as long as 24 hours. For improved stability, the clamp should be fi xed with a screw. For this purpose, a self-tapping screw and an M4 bolt and nut are included. Place the cable into the clamp as shown in the illustration above and fi rmly press down the internal top cover until the cable is fi xed. Appendix XI Appendix 3: Software License Use of the software is subject to the Studer Professional Audio Software License Agreement set forth below. Using the software indicates your accep- tance of this license agreement. If you do not accept these license terms, you are not authorized to use this software. Under the condition and within the scope of the following Terms and Con- ditions, Studer Professional Audio GmbH (hereinafter “Studer”) grants the right to use programs developed by Studer as well as those of third parties which have been installed by Studer on or within its products. References to the license programs shall be references to the newest release of a license program installed at the Customers site. Programs Covered by the Agreement License Programs of Studer The following Terms and Conditions grant the right to use all programs of Studer that are part of the System and/or its options at the time of its delivery to the Customer, as well as the installation software on the original data disk and the accompanying documentation (“License Material”). In this Agree- ment the word “Programs” shall have the meaning of programs and data written in machine code. Using the software indicates your acceptance of this license agreement. If you do not accept these license terms, you are not authorized to use this soft- ware. Programs of Third Parties Programs of third parties are all programs which constitute part of the System and/or its options at the time of delivery to the Customer but have not been developed by Studer. The following conditions are applicable to programs of third parties: The right to use third parties programs is governed by the License Agree- ment attached hereto (if applicable), which is an integral part of this Agree- ment. The Customer shall sign any and all License Agreements for all further programs of third parties installed on the system. The Customer shall be deemed to have received all License Agreements upon delivery of the system and/or its options. Studer shall accept no responsibility or liability for, and gives no warran- ties (express or implied) as to the programs of third parties. The Customer waives any and all claims versus Studer for any consequential damages, which might occur due to defects of these programs. Right of Use Principle Studer grants the Customer the non-exclusive right to use the License Ma- terial in one copy on the system and/or its options as laid down by the Sales Agreement concluded between the parties and all Terms and Conditions which shall be deemed to form and be read and construed as part of the Sales Agreement. This right is assignable according to the “Assignability” paragraph hereinafter. Customized Confi gurations The Customer is not entitled to alter or develop further the License Material except within the expressly permitted confi guration possibilities given by the software installed on the system or elsewhere. All altered programs, includ- Appendix XII ing but not limited to the products altered within the permitted confi guration possibilities, are covered by this License Agreement. Reverse Engineering Reverse engineering is only permitted with the express consent of Studer. The consent of Studer can be obtained but is not limited to the case in which the interface software can not be provided by Studer. In any case Studer has to be informed immediately upon complete or partial reverse engineering. Copying the License Material The Customer is entitled to make one copy of all or parts of the License Material as is necessary for the use according to this Agreement, namely for backup purposes. The Customer shall apply the copyright of Studer found on the License Material onto all copies made by him. Records shall be kept by the Customer regarding the amount of copies made and their place of keeping. The responsibility for the original program and all copies made lies with the Customer. Studer is entitled to check these records on fi rst request. Copies not needed anymore have to be destroyed immediately. Disclosure of License Material The License Material is a business secret of Studer. The Customer shall not hand out or in any way give access to parts of or the complete License Material to third parties nor to publish any part of the License Material without prior written consent of Studer. The Customer shall protect the License Material and any copies made according to the paragraph above by appropriate defense measures against unauthorized access. This obligation of non-disclosure is a perpetual obligation. Third parties are entitled to have access to the License Material if they use the License Material at the Customers site in compliance with this Agreement. Under no circumstance are third parties entitled to have access to the instal- lation software on the original data media. The Customer shall safeguard the original data media accordingly. Assignability The rights granted to the Customer according to this License Agreement shall only be assignable to a third party together with the transfer of the system and/or its options and after the prior written consent of Studer. Rights to License Material With the exception of the right of use granted by this License Agreement all proprietary rights to the License Material, especially the ownership and the intellectual property rights (such as but not limited to patents and copyright) remain with Studer even if alterations, customized changes or amendments have been made to the License Material. Studers proprietary rights are acknowledged by the Customer. The Customer shall undertake no infringements and make no claims of any patent, registered design, copyright, trade mark or trade name, or other intellectual property right. Warranty, Disclaimer, and Liability For all issues not covered herewithin, refer to the “General Terms and Condi- tions of Sales and Delivery” being part of the sales contract. Appendix D950 Digital Mixing System Date printed: 03.09.03SW V3.3Introduction 1-1 CHAPTER 1 1Introduction .1-3 1.1Technical Features and User Benefits.1-3 1.1.1Leading-Edge Digital Technology.1-3 1.1.2Typical System Applications .1-9 1.1.3Ergonomics and Ease-of-Use.1-9 1.1.4Audio Quality .1-10 1.2System Components.1-11 1.2.1Audio I/O Interfaces .1-11 1.2.2Safety and Reliability Redundancy, Hot-Swap Functions.1-11 1.2.3Session Configuration.1-12 1.2.4Channel Topologies and Types.1-14 1.3Basic System Block Diagram.1-16 D950 Digital Mixing System Date printed: 03.09.03SW V3.3Introduction 1-3 1 INTRODUCTION 1.1 Technical Features and User Benefits Studer is an international company with a long tradition in audio engi- neering and design perfection. It has now taken a major step forward by developing an all-new, state-of-the-art technology for digital mixing con- soles. Based on many years of experience in the recording studio, live- performance and post-production markets, allied to the latest advances in scientific achievements, Studer has created a new product family: the D950 Series Digital Mixing System. By utilizing the industrys most modern technology, users have access to superior amounts of processing power allied to fast system response to every operator command. In addition, space requirements and power con- sumption are minimized. The D950 Series flexible control surface and er- gonomics has been designed specifically to address the exacting demands of day-to-day recording and production sessions, especially when utilized in live applications. Access to all functions is quick and intuitive. 1.1.1 Leading-Edge Digital Technology The D950 Se

    注意事项

    本文(studer D950_Op_V3-5 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开