欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    Marantz-PM6004v1-int-sm 电路图 维修手册.pdf

    • 资源ID:243779       资源大小:14.97MB        全文页数:66页
    • 资源格式: PDF        下载积分:15积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Marantz-PM6004v1-int-sm 电路图 维修手册.pdf

    Service Manual Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifications and design are subject to change without notice. Integrated Amplifier PM6004 /N1SG/N1B/K1B/U1B PM6004 S0314-0V01DM/DG1108Copyright 2011 D&M Holdings Inc. All rights reserved. WARNING: Violators will be prosecuted to the maximum extent possible. Ver. 1 2 CONTENTS SAFETY PRECAUTIONS .4 NOTE FOR SCHEMATIC DIAGRAM .5 TECHNICAL SPECIFICATIONS .6 DIMENSION .6 CAUTIONS IN SERVICING .7 Initializing INTEGRATED AMPLIFIER .7 DISASSEMBLY .8 1. FRONT PANEL ASSY .9 2. MAIN & VOLUME PWB UNIT .12 3. POWER TRANS .13 4. SUB TRANS .13 WHEN THE MICROPROCESSOR IS REPLACED WITH A NEW ONE .14 SERVICE MODE .31 ADJUSTMENT .32 TROUBLE SHOOTING .34 1. The power can not be turned on. (STANDBY LED does not light (STANDBY MODE) . 34 2. The power can not be turned on. (STANDBY LED lightsflash) . 34 3. STANDBY LED flashes while using unit. (protection circuit is set) . 35 4. The power turned on, but a sound does not output normally. (Both channels) . 35 BLOCK DIAGRAM .37 POWER SUPPLY BLOCK DIAGRAM .38 LEVEL DIAGRAM .39 PRINTED WIRING BOARDS .40 FRONT .40 VOLUME .41 STANDBY .41 POWER SW .42 POSISTER .42 HEADPHONE .42 TRANS PRI .42 TRANS SEC .42 MAIN .43 SCHEMATIC DIAGRAMS .45 MAIN UNIT .45 FRONT UNIT .46 VOLUME UNIT .47 STANDBY UNIT .47 POWER SW UNIT.47 HEADPHONE UNIT .47 POSISTER UNIT .47 WIRING DIAGRAM .48 EXPLODED VIEW .49 PARTS LIST OF EXPLODED VIEW .51 PACKING VIEW .53 PARTS LIST OF PACKING & ACCESSORIES .53 SEMICONDUCTORS .55 1. ICs .55 PARTS LIST OF P.C.B. UNIT .58 8U-110004A MAIN PWB UNIT ASSY (N,K model) .58 8U-110004B MAIN PWB UNIT ASSY (U model) .58 8U-110005A FRONT PWB UNIT ASSY (N,K model) .63 8U-110005B FRONT PWB UNIT ASSY (U model) .63 3 MARANTZ DESIGN AND SERVICE Using superior design and selected high grade components, MARANTZ company has created the ultimate in stereo sound. Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifications for which it is famous. Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered either by mail or by Fax. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3. Description of parts 4. Model number for which part is required 5. Way of shipment 6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void. In case of difficulties, do not hesitate to contact the Technical Department at above mentioned address. 091105DM/DG USA MARANTZ AMERICA, INC 100 CORPORATE DRIVE MAHWAH, NEW JERSEY 07430 USA EUROPE / TRADING D&M EUROPE B. V. P. O. BOX 8744, BUILDING SILVERPOINT BEEMDSTRAAT 11, 5653 MA EINDHOVEN THE NETHERLANDS PHONE : +31 - 40 - 2507844 FAX : +31 - 40 - 2507860 KOREA D&M SALES AND MARKETING KOREA LTD. 2F,YEON BLDG., 88-5, BANPO-DONG, SEOCHO-GU, SEOUL KOREA PHONE : +82 - 2 - 715 - 9041 FAX : +82 - 2 - 715 - 9040 CANADA D&M Canada Inc. 5-505 APPLE CREEK BLVD. MARKHAM, ONTARIO L3R 5B1 CANADA PHONE : 905 - 415 - 9292 FAX : 905 - 475 - 4159 JAPAN D&M BUILDING, 2-1 NISSHIN-CHO, KAWASAKI-KU, KAWASAKI-SHI, KANAGAWA, 210-8569 JAPAN D&M Holdings Inc. CHINA D&M SALES AND MARKETING SHANGHAI LTD. ROOM.808 SHANGHAI AIRPORT CITY TERMINAL NO.1600 NANJING (WEST) ROAD, SHANGHAI, CHINA. 200040 TEL : 021 - 6248 - 5151 FAX : 021 - 6248 - 4434 SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins (with unit NOT connected to AC mains and its Power switch ON), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer. Ref. UL Standard No. 60065. NOTE ON SAFETY : Symbol z Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol z . Any other component substitution (other than original type), may increase risk of fire or electrical shock hazard. 安全上注意: z 部品、安全上重要部品。必指定部品番号部品使用下。 4 SAFETY PRECAUTIONS The following items should be checked for continued protection of the customer and the service technician. LEAKAGE CURRENT CHECK Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable. CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock! (1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when replacing parts, for example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed! For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and the structural parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams .Indicated by the z mark. (2) Parts lists .Indicated by the z mark. The use of parts other than the designated parts could cause electric shocks, fires or other dangerous situations. CAUTION Concerning important safety parts 5 NOTE FOR SCHEMATIC DIAGRAM WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer. CAUTION: Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DO NOT return the set to the customer unless the problem is identified and remedied. NOTICE: ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. Parts indicated by nsp on this table cannot be supplied. When ordering a part, make a clear distinction between 1 and I (i) to avoid mis-supplying. A part ordered without specifying its part number can not be supplied. General-purpose Carbon Chip Resistors are not included are not included in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.) Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer. General-purpose Carbon Film Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.) Part indicated by mark is not illustrated in the exploded view. WARNING: 1. 2. 3. 4. 5. 6. Resistors RD:Carbon RC:Composition RS :Metal oxide film RW:winding RN:Metal film RK :Metal mixture P:Pulse-resistant type NL :Low noise type NB :Non-burning type FR :Fuse-resistor F:Lead wire forming 2B :1/8 W 2E :1/4 W 2H :1/2 W 3A :1 W 3D :2 W 3F :3 W 3H :5 W F:1% G:2% J:5% K:10% M :20% Ex.:RN Type 14K Shape and per- formance 2E Power 182 Resist- ance G Allowable error FR Others * Resistance 1800ohm=1.8kohm1 82 Indicates number of zeros after effective number. 2-digit effective number. 1.2ohm1 R2 2-digit effective number, decimal point indicated by R. 1-digit effective number. : Units: ohm NOTE FOR PARTS LIST 6 RMS Power output (20 Hz 20 kHz simultaneous drive of both channels): 45 W x 2 (8 load) 60 W x 2 (4 load) Total harmonic distortion (20 Hz 20 kHz simultaneous drive of both channels, 8 load):0.08 % Output band width (8 load, 0.06 %):10 Hz 50 kHz Frequency response (CD, 1 W, 8 load):10 Hz 70 kHz +0 dB, -1 dB Dumping factor (8 load, 40 Hz 20 kHz):100 Input sensitivity/Input impedance PHONO (MM):2.2 mV/47 k CD, TUNER, AUX/DVD, RECORDER:200 mV/20 k Maximum allowable PHONO input level (1 kHz) MM:100 mV RIAA deviation (20 Hz 20 kHz):1.0 dB S/N (IHF-A, 8 load) PHONO (MM):83 dB (5 mV input, 1 W output) CD, TUNER, AUX/DVD, RECORDER:102 dB (2 V input, Rated output) Tone control Bass (50 Hz):10 dB Treble (15 kHz):10 dB Power requirement:AC 230 V 50/60 Hz (N) AC 220 V 50 Hz (K) AC 120 V 60 Hz (U) Power consumption (EN60065):150 W Power consumption during standby:0.2 W Weight:7.4 kg TECHNICAL SPECIFICATIONS 32925 370 16 90 104 14 440 DIMENSION 7 CAUTIONS IN SERVICING Initializing INTEGRATED AMPLIFIER INTEGRATED AMPLIFIER initialization should be performed when the com and peripheral parts of com were replaced. 1. Turn off the power pressing POWER button. 2. Press POWER button wh

    注意事项

    本文(Marantz-PM6004v1-int-sm 电路图 维修手册.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开