欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    Marantz-PM8005v6-int-sm 电路图 维修手册.pdf

    • 资源ID:248440       资源大小:7.65MB        全文页数:51页
    • 资源格式: PDF        下载积分:15积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Marantz-PM8005v6-int-sm 电路图 维修手册.pdf

    START:|g1cz3Z09ximWbk6cjE4rRA=|mg9g+GZSrubJjFbzRGSxCVc7rGTC/B0gkPTJx5lic8=|PLXqzLbC2dLvdexZ9XDk1w=|:END Integrated Amplifier PM8005 /N1B/N1SG U1B/K1B PM8005 S1165V06DM/DG1512 Copyright 2015 D&M Holdings Inc. All rights reserved. WARNING: Violators will be prosecuted to the maximum extent possible. Ver. 6 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifications and design are subject to change without notice. Please refer to the MODIFICATION NOTICE. Service Manual RadioFans.CN 收音机爱 好者资料库 ABOUT THIS MANUAL .3 What you can do with this manual .3 Using Adobe Reader (Windows version) .4 SAFETY PRECAUTIONS .6 NOTE FOR SCHEMATIC DIAGRAM .7 NOTE FOR PARTS LIST .7 TECHNICAL SPECIFICATIONS .9 DIMENSION .9 DISASSEMBLY .10 1. FRONT PANEL ASSY .11 2. HEAT SINK ASSY .12 3. PHONO AMP PCB .13 4. STANDBY PCB .13 5. REAR PANEL ASSY .14 6. MAIN PCB .14 SPECIAL MODE .15 1. SERVICE MODE .15 2. PROTECTION MODE .16 Procedure after Replacing the MicroPROCESSOR, etc.18 ADJUSTMENT .19 TROUBLE SHOOTING .21 1. The power can not be turned on. (STANDBY LED does not light (STANDBY MODE) .21 2. The power can not be turned on. (STANDBY LED lights flash) .21 3. STANDBY LED FLASHES WHILE USING UNIT .22 4. The power turned on, but a sound does not output normally. .22 LEVEL DIAGRAM .23 BLOCK DIAGRAM .23 POWER DIAGRAM .23 WIRING DIAGRAM .24 PRINTED Circuit BOARDS .25 SCHEMATIC DIAGRAMS (1/6 ) .29 MAIN .29 MAIN / POWER STAGE 1/2 .30 MAIN / POWER STAGE 2/2 .31 U-COM / SELECTOR .32 POWER AMP / SPK TERMINAL / TONE .33 HEADPHONE / POWER SW / STANDBY .34 PHONO AMP / SPK TERMINAL / VOLUMERECT .35 EXPLODED VIEW .36 PACKING VIEW .37 SEMICONDUCTORS .38 1. ICs .38 2 CONTENTS RadioFans.CN 收音机爱 好者资料库 Jump to the target of a schematic diagram connector Click the Ref. No. of the target connector in the red box around a schematic diagram connector. The screen jumps to the target connector. Pagemagnificationstaysthesameasbeforethe jump. ABOUT THIS MANUAL Read the following information before using the service manual. What you can do with this manual Search for a Ref. No. (phrase) (Ctrl+Shift+F) You can use the search function in Acrobat Reader to search for a Ref. No. in schematic diagrams, printed wiring circuit diagrams, block diagrams, and parts lists. 1.Press Ctrl+Shift+Fonthekeyboard. The Search window appears. 2.EntertheRef.No.youwanttosearchforinthe Search window, and then click the Search button. A list of search results appears. 3.Click an item on the list. The screen jumps to the page for that item, and the searchphraseisdisplayed. Ctrl Shift F 3 RadioFans.CN 收音机爱 好者资料库 Using Adobe Reader (Windows version) Properties Click this button and check that the printer is set to a suitable paper size. Page to print Select the following checkbox. More Options : Current View Page Sizing & Handling Select the following checkbox. Size / Size Options : Fit Add notes to this data (Sign) TheSignfunctionletsyouaddnotestothedatain this manual. Savethefileonceyouhavefinishedaddingnotes. Example using Adobe Reader X On the View menu, click Sign. The Sign pane appears. Example using Adobe Reader 9 On the Document menu, click Sign. Magnify schematic / printed circuit board diagrams - 1 (Ctrl+Space, mouse operation) Press Ctrl+Spaceonthekeyboardanddragthe mousetoselecttheareayouwanttoview. Theselectedareaismagnified. Whenyouwanttomovetheareashown,hold down Space and drag the mouse. Whenyouwanttoshowafullpageview,press Ctrl+0onthekeyboard. CtrlSpace 0 Print a magnified part of the manual ThePropertiesdialogboxandfunctionswillvarydependingonyourprinter. 1. Dragthemousetomagnifythepartyouwanttoprint. 2. On the File menu, click Print. 3. ConfigurethefollowingsettingsinthePrintdialogbox. 4. Click the Print button to start printing. 4 Magnify schematic / printed circuit board diagrams - 2 (Pan & Zoom function) ThePan&Zoomfunctionletsyouseewhichpartof amagnifieddiagramisbeingshowninaseparate window. Example using Adobe Reader X On the View menu, point to Zoom, and then click Pan & Zoom. The Pan & Zoom window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Pan & Zoom Window. Magnify schematic / printed circuit board diagrams - 3 (Loupe Tool function) TheLoupeToolfunctionletsyoumagnifyaspecific part of a diagram in a separate window. Example using Adobe Reader X On the View menu, point to Zoom, and then click Loupe Tool. The Loupe Tool window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Loupe Tool Window. 5 SAFETY PRECAUTIONS The following items should be checked for continued protection of the customer and the service technician. leakage current check Beforereturningthesettothecustomer,besuretocarryouteither(1)aleakagecurrentcheckor(2)alinetochassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on,offandstandbymode),ifapplicable. CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock! (1) AnACvoltageisimpressedonthisset,soifyou touch internal metal parts when the set is energized, youmaygetanelectricshock.Avoidgettingan electricshock,byusinganisolatingtransformer and wearing gloves when servicing while the set is energized,orbyunpluggingthepowercordwhen replacing parts, for example. (2) Therearehighvoltagepartsinside.Handlewith extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufacturedfromsheetmetal,theremaybeburrson theedgesofparts.Theburrscouldcauseinjuryiffingers are moved across them in some rare cases. Wear gloves toprotectyourhands. Use only designated parts! Thesetspartshavespecificsafetyproperties(fire resistance,voltageresistance,etc.).Besuretouseparts which have the same properties for replacement. The burrs have the same properties. In particular, for the importantsafetypartsthatareindicatedbythez mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed! Forsafetyseasons,somepartsusetapes,tubesorother insulatingmaterials,andsomepartsaremountedaway from the surface of printed circuit boards. Care is also takenwiththepositionsofthewiresbyarrangingthem andusingclampstokeepthemawayfromheatingand highvoltageparts,sobesuretoseteverythingbackas itwasoriginallyplaced. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safetyisensured. (Insulationcheckprocedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistancevaluebetweentheinplugandtheexternally exposedmetalparts(antennaterminal,headphones terminal,inputterminal,etc.)is1Morgreater.Ifitis less, the set must be inspected and repaired. Manyoftheelectricandthestructuralpartsusedinthe sethavespecialsafetyproperties.Inmostcasesthese propertiesaredifficulttodistinguishbysight,andtheuse ofreplacementpartswithhigherratings(ratedpower andwithstandvoltage)doesnotnecessarilyguarantee thatsafetyperformancewillbepreserved.Partswith safetypropertiesareindicatedasshownbelowonthe wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1)Schematicdiagrams .Indicatedbythez mark. (2)Partslists .Indicatedbythez mark. The use of parts other than the designated parts could cause electric shocks,firesorotherdangerous situations. CAUTION Concerning important safety parts 6 NOTE FOR SCHEMATIC DIAGRAM WARNING: Partsindicatedbythezmarkhavecriticalcharacteristics.UseONLYreplacementpartsrecommendedbythemanufacturer. CAUTION: Beforereturningthesettothecustomer,besuretocarryouteither(1)aleakagecurrentcheckor(2)alinetochassisresistancecheck. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DONOTreturnthesettothecustomerunlesstheproblemisidentifiedandremedied. NOTICE: ALLRESISTANCEVALUESINOHM.k=1,000OHM/M=1,000,000OHM ALLCAPACITANCEVALUESAREEXPRESSEDINMICROFARAD,UNLESSOTHERWISEINDICATED.PINDICATESMICRO-MICRO FARAD.EACHVOLTAGEANDCURRENTAREMEASUREDATNOSIGNALINPUTCONDITION.CIRCUITANDPARTSARESUBJECT TOCHANGEWITHOUTPRIORNOTICE. NOTE FOR PARTS LIST 1.Partsindicatedbynsp on this table cannot be supplied. 2.Whenorderingapart,makeacleardistinctionbetween1andI(i)toavoidmis-supplying. 3.Apartorderedwithoutspecifyingitspartnumbercannotbesupplied. 4.Partindicatedby mark is not illustrated in the exploded view. WARNING:Partsindicatedbythezmarkhavecriticalcharacteristics.UseONLYreplacementpartsrecommendedbythemanufacturer. INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNIT Electrostaticbreakdownofthesemi-conductorsoropticalpickupmayoccurduetoapotentialdifferencecausedby electrostatic charge during unpacking or repair work. 1. GroundforHumanBody Besuretowearagroundingband(1M)thatisproperlygroundedtoremoveanystaticelectricitythatmaybe chargedonthebody. 2. GroundforWorkbench Besuretoplaceaconductivesheetorcopperplatewithpropergrounding(1M)ontheworkbenchorothersurface, wherethesemi-conductorsaretobeplaced.Becausethestaticelectricitychargeonclothingwillnotescapethrough thebodygroundingband,becarefultoavoidcontactingsemi-conductorswithyourclothing CBA Grounding Band Conductive Sheet or Copper Plate 1M 1M CBA 7 Personal notes: 8 RMS Power output (for U / N / F model) (20 Hz 20 kHz simultaneous drive of both channels) : 70 W x 2 (8 /ohms load) 100 W x 2 (4 /ohms load) RMS Power output (for K model) (20 Hz 20 kHz simultaneous drive of both channels) : 65 W x 2 (8 /ohms load) 95 W x 2 (4 /ohms load) Total harmonic distortion (20 Hz 20 kHz simultaneous drive of both channels, 8 /ohms load) : 0.02 % Output band width (8 /ohms load, 0.06 %) : 5 Hz 60 kHz Frequency response (CD, 1 W, 8 /ohms load) : 5 Hz 100 kHz 3 dB Dumping factor (8 /ohms load, 40 Hz 20 kHz) : 100 Input sensitivity/Input impedance PHONO (MM) : 2 mV / 47 k/kohms CD, TUNER, NETWORK, AUX, RECORDER : 200 mV / 20 k/kohms POWER AMP DIRECT IN : 1.6 V / 15 k/kohms Output voltage/Output impedance PRE OUT : 1.6 V / 600 /ohms Maximum allowable PHONO input level (1 kHz) MM : 100 mV RIAA deviation (20 Hz 20 kHz) : 0.5 dB S/N (IHF-A, 8 /ohms load) PHONO (MM) : 87 dB (5 mV input, 1 W output) CD, TUNER, NETWORK, AUX, RECORDER : 106 dB (2 V input, Rated output POWER AMP DIRECT IN : 125 dB (Rated output) Tone control Bass (50 Hz) : 10 dB Mid (900 Hz) : 6 dB Treble (15 kHz) : 10 dB Power requirement (for U model) : AC 120 V, 60 Hz Power requirement (for N model) : AC 230 V, 50/60 Hz Power requirement (for K model) : AC 220 V, 50 Hz Power requirement (for F model) : AC 100 V, 50/60 Hz Power consumption (EN60065 / UL60065) : 220 W Power consumption in standby mode : 0.2 W Unit : in. (mm) Weight : 12.0 kg 329 379 2255945 17111 128 440 340 56 5050 1733 TECHNICAL SPECIFICATIONS DIMENSION 9 FRONT PANEL ASSY See DISASSEMBLY 1. FRONT PANEL ASSY and EXPLODED VIEW u-COM PCB (110151-1) (Ref. No. of EXPLODED VIEW : P4) STANDBY LED PCB (110151-2) (Ref. No. of EXPLODED VIEW : P5) INPUT SEL PCB (110151-3) (Ref. No. of EXPLODED VIEW : P6) TONE PCB (110151-4) (Ref. No. of EXPLODED VIEW : P7) HEADPHONE PCB (110151-5) (Ref. No. of EXPLODED VIEW : P8) POWER SW PCB (110151-7) (Ref. No. of EXPLODED VIEW : P10) VOLUME PCB (110152-3) (Ref. No. of EXPLODED VIEW : P14) REAR PANEL ASSY See DISASSEMBLY 5. REAR PANEL ASSY and EXPLODED VIEW SPK TERMINAL PCB (110152-2) (Ref. No. of EXPLODED VIEW : P13) MAIN PCB See DISASSEMBLY 6. MAIN PCB and EXPLODED VIEW MAIN PCB (110150-1) (Ref. No. of EXPLODED VIEW : P1) PHONO AMP PCB See DISASSEMB

    注意事项

    本文(Marantz-PM8005v6-int-sm 电路图 维修手册.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开