欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    Panasonic-SAAKX100P-cs-sm 电路图 维修手册.pdf

    • 资源ID:255246       资源大小:6.75MB        全文页数:59页
    • 资源格式: PDF        下载积分:15积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Panasonic-SAAKX100P-cs-sm 电路图 维修手册.pdf

    Panasonic Corporation 2016. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1608001CE CD Stereo System Model No.SA-AKX100PN SA-AKX100PR SA-AKX100PS Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 3 1.1. General Guidelines- 3 1.2. Before Repair and Adjustment- 4 1.3. Protection Circuitry- 4 1.4. Safety Parts Information- 5 2 Warning- 6 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices- 6 2.2. Precaution of Laser Diode- 6 2.3. General description about Lead Free Solder (PbF)- 7 2.4. Handling Precautions for Traverse Unit- 7 2.5. Grounding for electrostatic breakdown prevention - 8 3 Service Navigation- 9 3.1. Service Information - 9 4 Specifications- 10 5 Location of Controls and Components- 11 5.1. Remote Control Key Button Operation - 11 5.2. Main Unit Key Button Operation- 12 6 Service Mode- 13 6.1. Cold-Start - 13 6.2. Sales Demonstration Lock Function - 13 6.3. Doctor Mode Table- 14 6.4. Self-Diagnostic Mode - 16 6.5. Self-Diagnostic Error Code Table- 16 7 Troubleshooting Guide - 18 7.1. No Power or No Display- 18 7.2. Bluetooth Pairing Failure- 18 7.3. No Key Function- 18 7.4. No Remote Control Function- 19 7.5. USB Device Cannot Detect- 19 Please refer to the original service manual for: ? ? CD Mechanism Unit (BRS12C) , Order No. PSG1303059AE ? ? Speaker system SB-AKX100PNK, Order No. PSG1608002CE RadioFans.CN 收音机爱 好者资料库 2 7.6. No Output Sound-19 7.7. Check Point-20 8 Disassembly and Assembly Instructions-21 8.1. Types of Screws-21 8.2. Disassembly Flow Chart-22 8.3. Main Components and P.C.B. Locations-22 8.4. Disassembly of Top Cabinet-23 8.5. Disassembly of Front Panel Unit-23 8.6. Disassembly of Panel P.C.B.-24 8.7. Disassembly of Main P.C.B.-25 8.8. Disassembly of SMPS Module -25 8.9. Disassembly of Rear Cabinet-26 8.10. Disassembly of CD Mechanism Unit-27 8.11. Disassembly of CD Interface P.C.B.-28 9 Service Position-29 9.1. Checking of Panel P.C.B. and Main P.C.B.-29 10 Block Diagram -31 10.1. System Control -31 10.2. Audio -32 10.3. Power Supply -33 11 Wiring Connection Diagram-34 12 Schematic Diagram-35 12.1. Schematic Diagram Notes-35 12.2. Main (Micon) Circuit (1/2) -37 12.3. Main (Micon) Circuit (2/2) -38 12.4. Main (AUX Tuner) Circuit -39 12.5. Main (DSP), Main (Bluetooth) and CD Interface Circuit-40 12.6. Main (DAMP) Circuit-41 12.7. Main (Voltage Regulator) Circuit -42 12.8. Panel Circuit-43 13 Printed Circuit Board -44 13.1. Main P.C.B. -44 13.2. Panel, CD Interface P.C.B.-45 14 Voltage and Waveform Measurement -47 14.1. Voltage Measurement-47 15 Exploded View and Replacement Parts List-51 15.1. Cabinet Parts Location 1-51 15.2. Packaging-52 15.3. Mechanical Replacement Part List -53 15.4. Electrical Replacement Parts List-55 RadioFans.CN 收音机爱 好者资料库 3 1Safety Precautions 1.1.General Guidelines 1. IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modify the original design without permission of manufacturer. 2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during servicing. 3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed. 5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards. 1.1.1.Leakage Current Cold Check 1. Unplug the AC cord and connect a jumper between the two prongs on the plug. 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading should be between 1M and 5.2M. When the exposed metal does not have a return path to the chassis, the reading must be 1.1.2.Leakage Current Hot Check 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a 1.5k, 10 watts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Figure 1-1. 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer. Figure 1-1 RadioFans.CN 收音机爱 好者资料库 4 1.2.Before Repair and Adjustment Disconnect AC power to discharge AC capacitor (in SMPS Module) as indicate below diagram through a 10 , 10 W resistor to ground. Caution: DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices. After repairs are completed, restore power gradually using a variac to avoid overcurrent. Current consumption at AC 120 V, 60 Hz in Power ON, FM Tuner at volume minimal mode should be 350 mA (for PN). Current consumption at AC 220240 V, 50/60 Hz in Power ON, FM Tuner at volume minimal mode should be 350 mA (for PR/ PS). 1.3.Protection Circuitry The protection circuitry may have operated if either of the following conditions are noticed: No sound is heard when the power is turned on. Sound stops during a performance. The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are “shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used. If this occurs, follow the procedure outlines below: 1. Turn off the power. 2. Determine the cause of the problem and correct it. 3. Turn on the power once again after one minute. Note: When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again. 5 1.4.Safety Parts Information Safety Parts List: There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Exploded View OPEN/CLOSE and USB/CD keys for 5 sec or more. The display will show upon entering into this mode for 2 sec. Note: ;OPEN/CLOSE button is invalid and the main unit displays LOCK while the lock function mode is entered. Cancellation of Sales Demonstration Lock Mode To cancel the sales demonstration lock mode. 1. Turn on the unit. 2. Select to CD mode function. 3. Set volume to Vol 19. 4. Press and hold ;OPEN/CLOSE and USB/CD keys for 5 sec or more. The display will show upon entering into this mode for 2 sec. FL Display Key Operation Front Key Item DescriptionMode Name 14 6.3.Doctor Mode Table 6.3.1.Doctor Mode Table 1 FL Display Key Operation Front Key Item DescriptionMode Name Doctor Mode EEPROM checksum check :edoMDCnIedoMro t c oDot n i retneoT 1. Press button on main unit follow by 4 and 7 on remote control. In CD mode: 1. Enter into Doctor Mode 2. To exit, press DELETE button on remote control or, press POWER, /I button on Main Unit Displaying of 1. Year Develop. 2. Model Type. 3. ROM Type. 4. Firmware Version. (Display 1) Cold StartTo active cold start upon next AC power up when reset start is execute the next time. In Doctor Mode: 1. Press 4 button on the remote control. (Decimal)1234 Version No. (001 999) specific for each firmware 15 6.3.2.Doctor Mode Table 2 FL Display Key Operation Front Key Item DescriptionMode Name Volume Setting Check FL Display Check To check the volume setting of the main unit. To check the FL segment display. All segments will light up while all LED blink at 0.5s intervals. In Doctor Mode: 1. Press 7, 8, 9 button on the remote control. In Doctor mode: 1. Press 1 button on the remote control. 2. To cancel this mode, press 0 button on the remote control. Press 7: VOL50 Press 8: VOL35 Press 9: VOL0 Volume In this mode, the tray will open & close automatically. Cancellation Display Loading TestTo determine the open & close operation of the CD Mechanism Unit. The counter will increment by one. When reach 99999999 will change to 00000000 Cancellation Display Traverse TestTo determine the traverse unit operation for inner & outer access track. The counter will increment by one. When reach 99999999 will change to 00000000 The counter will increment by one. When reach 99999999 will change to 00000000 Cancellation Display Reliability Test (Combination) In this mode, ensure the CD is in the main unit. To determine the traverse unit operation & open/close operation of the mechanism. In this mode, ensure the CD is in the main unit. In Doctor Mode: 1. Press 10 2 1 button on the remote control. In Doctor Mode: 2. To cancel this mode, press 0 button on the remote control. 2. To cancel this mode, press 0 button on the remote control. 2. To cancel this mode, press 0 button on the remote control. 1. Press 10 1 2 button on the remote control. In Doctor Mode: 1. Press 10 1 5 button on the remote control. 2. To cancel this mode, press 0 button on the remote control. 16 6.4.Self-Diagnostic Mode 6.5.Self-Diagnostic Error Code Table Self-Diagnostic Function provides information on any problems occurring for the unit and its respective components by displaying the error codes. These error code such as U*, H* and F* are stored in memory and held unless it is cleared. The error code is automatically display after entering into self-diagnostic mode. 6.5.1.Power Supply Error Code Table FL Display Key Operation Front Key Item DescriptionMode Name Self Diagnostic Mode To enter into self diagnostic checkingStep 1: Select CD mode (Ensure no disc is inserted). To exit, press 8 on main unit or remote control. Step 2: Press & hold g button follow by y/i on main unit for 2 seconds. Error Code Information System will perform a check on any unusual/error code from the memory Example:Step 1: In self diagnostic mode, Press g on main unit. To exit, press 8 on main unit or remote control. Delete error code To clear the stored in memory (EEPROM IC) Step 1: In self diagnostic mode, Press 0 on remote control. Solution (PCB exchange repair) FL Display Key Operation Front Key Item DescriptionMode Name Error Code F61 Diagnosis Contents: Power Amp IC output abnormal. Upon power on, PCONT=HIGH, DC_DET_AMP after checking LSI. Error Code F76 Diagnosis Contents: Power Amp IC output abnormal. DC_DET_PWR. Error Code F61-76 Diagnosis Contents: Power Amp IC output abnormal. Both DCDET (NG). Press on main unit for next error. Press on main unit for next error. Press on main unit for next error. Check main (IC6000). Check SMPS P.C.B. (Main Q1011 / IC1000). DAMP and power supply abnormal. 17 6.5.2.CD Mechanism Error Code Table 6.5.3.Bluetooth Error Code Table Solution (PCB exchange repair) FL Display Key Operation Front Key Item DescriptionMode Name Error Code CD H15 Diagnosis Contents: CD Open Abnormal. During operation POS_SW_R On fail to be detected within 4 sec. Error No. shall be clear by force or during cold start. Error Code CD H16 Diagnosis Contents: CD Closing Abnormal. During operation POS_SW_CEN On fail to be detected within Error No. shall be clear by force Press on main unit for next error. Press on main unit for next error. 4 sec. Check following: 1. CD Interface P.C.B. (Pin 3, 4, 6) 2. SOC IC (IC2001) Check following: 1. CD Interface P.C.B. (Pin 6, 3, 4) 2. SOC IC (IC2001) Solution (PCB exchange repair) FL Display Key Operation Front Key Item DescriptionMode Name Error Code F703 Diagnosis Contents: Bluetooth Communication. Com

    注意事项

    本文(Panasonic-SAAKX100P-cs-sm 电路图 维修手册.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开