欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    Tascam_rs-232c_protocol_cd-500_e_ver101 电路图 维修手册.pdf

    • 资源ID:342742       资源大小:673.54KB        全文页数:25页
    • 资源格式: PDF        下载积分:10积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Tascam_rs-232c_protocol_cd-500_e_ver101 电路图 维修手册.pdf

    TASCAM CD-500/CD-500B CONTROL I/O Terminals RS-232C Protocol Specifications TEAC Corporation RadioFans.CN 收音机爱 好者资料库 1. Overview The CD-500/CD-500B (“controlled device”) can be controlled from an external device (“external controller”), such as a computer, through a serial RS-232C connection. 2. Specifications 2.1. Electrical Specifications Standard JIS X-5101 (equivalent to the former JIS-C-6361 and EIA RS-232C standards) Note that this is not compatible with the RS-422 used in professional VTRs. Impedance at receiver When measured with an applied voltage between -3 V and +3 V or between -15 V and +15 V, the DC resistance is between 3 kohms and 7 kohms. Total load capacitance is 2500 pF or less. Open circuit voltage at transmitter 25V or less Open circuit voltage at receiver 2V or less Signal voltage When the open circuit voltage at the receiver is 0 V, the signal voltage is between -5 V and +5 V or between -15 V and +15V against a load impedance between 3 kohms and 7 kohms. Signal discrimination Logic “1”: -3V or less Logic “0”: +3V or more 2.2. Communication format Circuit type 3-wire, Half-duplex Transmission type Digital binary serial Data signal rate (baud rate) 9600/19200/38400 bits/sec Data bits 8 bits Parity bits None Stop bits 1 bit *Data signal rate can be set from the menu of the controlled device. Data bits, parity bits, and stop bits are fixed. RadioFans.CN 收音机爱 好者资料库 2.3. Connector pin-out Connector D-sub 9pin female (Inch screw thread) Terminal pin-out and input/output signals Pin No. In/Out Signal name Description 1 - NC Not connected 2 In Rx DATA Data received at this pin (*1) 3 Out Tx DATA Data transmitted from this pin 4 - (Reserved) Reserved 5 - GND Signal ground pin 6 - (Reserved) Reserved 7 Out RTS Short-circuit to Pin No. 8. 8 In CTS Short-circuit to Pin No. 7. 9 - NC Not connected *1: Make sure that a voltage applied to Pin No. 2 for Rx DATA conforms to the RS-232C standard. *2: Pins No. 7 and 8 are short-circuited to receive or transmit RTS/CTS signals. 2 3 5 Controlled device (CD-500/CD-500B) GND TXD RXD RXD TXD GND External controller 7 8 RadioFans.CN 收音机爱 好者资料库 RS-232C Protocol Specifications Rev. 1.01RS-232C Protocol Specifications Rev. 1.01 CD-500/500B CD-500/500B - 4 - 3. Command Format 3.1. Command Format Overview The command format is as follows. Byte 1 Byte 2 Byte 3 Byte 4 Byte 5Byte 6Byte 7Byte 8 Byte n LF ID Command Data 1Data 2Data 3Data 4 CR A command uses a 2-byte ASCII format, starting with Line Field (LF), which is followed by machine ID, and ending with Carriage Return (CR). For information about machine ID, see the section 3-2 Machine ID. A command is followed by a byte string, which consists of data ranging from 0 bytes (if the command includes no data) to 98 bytes, maximum. For detailed information about data, see each of the sections explaining commands. Note that capital letters are used for “A to F” for commands that use 0 to 9 and A to F as data values. Command examples Example 1: Sending the PLAY command to the controlled device with the machine ID=0 When the controlled device is in the stop or ready state, the PLAY command starts playing the controlled device. The PLAY command is 12 and sent in the following format. ID Command ASCII LF 0 1 2 CR HEX 0Ah 30h31h 32h 0Dh Example 2: Performing a direct search for the track 12 on the controlled device with the machine ID=0 To do a direct search for the track 12, DIRECT TRACK SEARCH PRESET command 23 is sent. Data bytes consist of 2-byte ASCII characters. A track number is specified in the DIRECT TRACK SEARCH PRESET command as shown below. Data 1 tens digit of the track number to be specified Data 2 ones digit of the track number to be specified Data 3 thousands digit of the track number to be specified Data 4 hundreds digit of the track number to be specified Based on the above rule, the send command is described as follows. 3.2. Machine ID The Machine ID is fixed at 0. A command with the machine ID other than 0 is ignored. ID Command Data: 12th track ASCII LF 0 2 3 1 2 0 0 CR HEX 0Ah 30h32h 33h 31h32h30h30h0Dh RS-232C Protocol Specifications Rev. 1.01RS-232C Protocol Specifications Rev. 1.01 CD-500/500B CD-500/500B - 5 - 3.3. Command Sequence In most cases, the controlled device does not send an ACK command in response to a transport control command or data preset command that is sent from an external controller. The controlled device sends a return command in response to a data sense command that requests the controlled device to return the controlled devices preset data values. If the controlled device switches from one state to another - from stop state to playback state, for example, or if an error occurs, the controlled device sends a command to notify the external controller about the state transition. Examples of command sequences are shown below. Make sure that commands are sent at a minimum of 20-millisecond intervals. Example 1: Using a transport control of the controlled device (e.g. playback) When entering the playback state after receiving the playback command, the controlled device sends the CHANGE STATUS command. The controlled device does not send an ACK command in response to this command. Command External controller Controlled device Status of the controlled device STOP PLAY - Sets the pitch control data to -1.0% Example 3: Requesting currently set data (e.g. pitch control data) When receiving the PITCH CONTROL DATA PRESET (Sense) command, the controlled device sends the set pitch control data. Command External controller Controlled device Status of the controlled device PITCH CONTROL DATA PRESET (Sense) - ERROR CODE 1-01 List of error codes ERROR Internal error code Description RS-232C error code ERR01 1 TOC read error 1-10 ERR09 9 Flash ROM error 1-09 ERR10 10 SDRAM check error 1-10 ERR13 13 System error 1-13 - 25 -

    注意事项

    本文(Tascam_rs-232c_protocol_cd-500_e_ver101 电路图 维修手册.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开