欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Philips-DVDR-3576-H-Service-Manual电路原理图.pdf

    • 资源ID:83443       资源大小:8.49MB        全文页数:85页
    • 资源格式: PDF        下载积分:25积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Philips-DVDR-3576-H-Service-Manual电路原理图.pdf

    Survey of versions:Published by FU-KC 0807 Service AV Systems Printed in The Netherlands Subject to modification/37 NTSCHDD when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6)4. Release the flat pack-IC from the CBA using tweezers. (Fig. S-1-6)CAUTION:1. The Flat Pack-IC shape may differ by models. Use an appropriate hot-air flat pack-IC desoldering machine, whose shape matches that of the Flat Pack-IC.2. Do not supply hot air to the chip parts around the flat pack-IC for over 6 seconds because damage to the chip parts may occur. Put masking tape around the flat pack-IC to protect other parts from damage. (Fig. S-1-2)Fig. S-1-11-3-3 DVDN_PC_SN3. The flat pack-IC on the CBA is affixed with glue, so be careful not to break or damage the foil of each pin or the solder lands under the IC when removing it.With Soldering Iron:1. Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder flux which is applied to all pins of the flat pack-IC, you can remove it easily. (Fig. S-1-3)2. Lift each lead of the flat pack-IC upward one by one, using a sharp pin or wire to which solder will not adhere (iron wire). When heating the pins, use a fine tip soldering iron or a hot air desoldering machine. (Fig. S-1-4)3. Bottom of the flat pack-IC is fixed with glue to the CBA; when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6)4. Release the flat pack-IC from the CBA using tweezers. (Fig. S-1-6)With Iron Wire:1. Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder flux which is applied to all pins of the flat pack-IC, you can remove it easily. (Fig. S-1-3)2. Affix the wire to a workbench or solid mounting point, as shown in Fig. S-1-5.3. While heating the pins using a fine tip soldering iron or hot air blower, pull up the wire as the solder melts so as to lift the IC leads from the CBA contact pads as shown in Fig. S-1-5.4. Bottom of the flat pack-IC is fixed with glue to the CBA; when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6)5. Release the flat pack-IC from the CBA using tweezers. (Fig. S-1-6)Note: When using a soldering iron, care must be taken to ensure that the flat pack-IC is not being held by glue. When the flat pack-IC is removed from the CBA, handle it gently because it may be damaged if force is applied.Hot-airFlat Pack-ICDesolderingMachineCBAFlat Pack-ICTweezersMasking TapeFig. S-1-2Flat Pack-ICDesoldering BraidSoldering IronFig. S-1-3Fine TipSoldering IronSharpPinFig. S-1-4To Solid Mounting PointSoldering IronIron WireorHot Air BlowerFig. S-1-5Fine TipSoldering IronCBAFlat Pack-ICTweezersFig. S-1-61-3-4 DVDN_PC_SN2. Installation1. Using desoldering braid, remove the solder from the foil of each pin of the flat pack-IC on the CBA so you can install a replacement flat pack-IC more easily.2. The “” mark on the flat pack-IC indicates pin 1. (See Fig. S-1-7.) Be sure this mark matches the 1 on the PCB when positioning for installation. Then presolder the four corners of the flat pack-IC. (See Fig. S-1-8.)3. Solder all pins of the flat pack-IC. Be sure that none of the pins have solder bridges.Instructions for Handling Semi-conductorsElectrostatic breakdown of the semi-conductors may occur due to a potential difference caused by electrostatic charge during unpacking or repair work.1. Ground for Human BodyBe sure to wear a grounding band (1 M) that is properly grounded to remove any static electricity that may be charged on the body.2. Ground for WorkbenchBe sure to place a conductive sheet or copper plate with proper grounding (1 M) on the workbench or other surface, where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing.Example :Pin 1 of the Flat Pack-ICis indicated by a “ “ mark.Fig. S-1-7PresolderCBAFlat Pack-ICFig. S-1-8CBAGrounding BandConductive Sheet orCopper Plate1M1MCBA1-4-1 E2H40FISFUNCTION INDICATOR SYMBOLSNote: If an error occurs, a message with the error number appears on the screen.Message SolutionError No.Error Description PriorityCan not record on this disc.Insert a recordable disc, and ensure the disc status satisfies the recording requirements.1 An error occurs during data reading. -2There is no reply for 15 seconds in Test Unit Ready.-3Cannot write the data after trying three times.-4 An error occurs with OPC. -5 During recovery in a record. -6An error occurs even if recovery has been tried three times.-7 An error occurs in a format. -8 It cannot start an encode. -9NV_PCK/RDI_PCK is not in encoded data.-10Encode Pause condition continued for 10 minutes.-11Encode Pause condition continued in normal REC condition for 10 minutes.-12Difference in the address and cannot get Stream ID of RDI/VIDEO.-13 It is a reply that “ATAPI is not readable.” -14Cannot write the data after recovering SMALL VMGI.-15Cannot write the data after DVD-R Reverse Track.-16 An error occurs in Finalize Close. -17 An error occurs in Rec Stop Close. -18 An error occurs in PCA Full (DVD_R). -19 Safety Stop occurs during editing. -20 High Speed Disc. 221 The disc is not formatted. 522 Disc Error has occurred. 324The disc except DVD-R/RW or finalized DVD-R.1This program is not allowed to be recorded.You cannot record copy- prohibited programs.25 During the Macrovision picture input. 1126 During the CGMS picture input. 12This program is not recordable in Video mode.You cannot record copy- prohibited programs.27During the CGMS picture input. (Video Format Disc)-This program is not allowed to be recorded on this disc.You cannot record cop-y prohibited programs.28During the CGMS picture input. (VR Format Disc)-This disc is protected and not recordable.Release the disc protection setting in the Disc Setting menu.29 Disc Protected Disc. 6Recording ErrorYou cannot record on this disc as Power Calibration Area is full.E35 Error No.Error message

    注意事项

    本文(Philips-DVDR-3576-H-Service-Manual电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2023 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开