欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Philips-DVP-3600-X-Service-Manual电路原理图.pdf

    • 资源ID:83707       资源大小:1.77MB        全文页数:34页
    • 资源格式: PDF        下载积分:22积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Philips-DVP-3600-X-Service-Manual电路原理图.pdf

    TABLE OF CONTENTS PageVersion 1.0 Service Manual PHILIPS GB © All rights reserved. No part of this publication may be reproduced, stored in aretrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips. CLASS 1 LASER PRODUCT Service DVD Player Copyright 2011 Philips Consumer Electronics B.V. Eindhoven, The Netherlands Published by LLL - 1220 BU AVM Printed in The Netherlands Subject to modification 3141 785 38070 DVP3600X DVP3600X/77Specification.1-2 Safety Instruction,Warning & Notes.1-3 Mechanical and Dismantling Instruction.2-1 Software Upgrades.3-1 Trouble Shooting .4-1 Wiring Diagram.5-1 Electrical Diagram and Print-layout.6-1 Mechanical Exploded View.7-1 Revision List.8-1Safety instruction 1. General safety Safety regulations require that during a repair: . Connect the unit to the mains via an isolation transformer. . Replace safety components indicated by the symbol , only by components identical to the original ones. Any other component substitution (other than original type) may increase risk of fire or electrical shock hazard. Safety regulations require that after a repair, you must return the unit in its original condition. Pay, in particular, attention to the following points: . Route the wires/cables correctly, and fix them with the mounted cable clamps. . Check the insulation of the mains lead for external damage. . Check the electrical DC resistance between the mains plug and the secondary side: 1) Unplug the mains cord, and connect a wire between the two pins of the mains plug. 2) Set the mains switch the “on” position (keep the mains cord unplug). 3) Measure the resistance value between the mains plug and the front panel, controls, and chassis bottom. 4) Repair or correct unit when the resistance measurement is less than 1M . 5) Verify this, before you return the unit to the customer/user (ref. UL-standard no. 1492). 6) Switch the unit “off”, and remove the wire between the two pins of the mains plug. 2.Laser safety This unit employs a laser. Only qualified service personnel may remove the cover, or attempt to service this device (due to possible eye injury). Laser device unit T ype : Semiconductor laser GaAlAs Wavelength : 650nm (DVD) : 780nm (VCD/CD) Output power : 7mW (DVD) : 10mW (DVD /CD) Beam divergence: 60 degree Note: Use of controls or adjustments or performance of procedure other than those specified herein, may result in hazardous radiation exposure. Avoid direct exposure to beam. Safety instruction, Warning & Notes 1-2Warning 1.General . All ICs and many other semiconductors are susceptible to electrostatic discharges (ESD). Careless handing during repair can reduce life drastically. Make sure that, during repair, you are at the same potential as the mass of the set by a wristband with resistance. Keep components and tools at this same potential. Available ESD protection equipment: 1) Complete kit ESD3 (small tablemat, wristband, connection box, extension cable and earth cable) 4822 310 10671. 2) Wristband tester 4822 344 13999. . Be careful during measurements in the live voltage section. The primary side of the power supply , including the heat sink, carries live mains voltage when you connect the player to the mains (even when the player is “off”!). It is possible to touch copper tracks and/or components in this unshielded primary area, when you service the player. Service personnel must take precautions to prevent touching this area or components in this area. A “lighting stroke” and a stripe-marked printing on the printed wiring board, indicate the primary side of the power supply. . Never replace modules, or components, while the unit is “on”. 2. Laser . The use of optical instruments with this product, will increase eye hazard. . Only qualified service personnel may remove the cover or attempt to service this device, due to possible eye injury. . Repair handing should take place as much as possible with a disc loaded inside the player. . Text below is placed inside the unit, on the laser cover shield: Notes: Manufactured under licence from Dolby Laboratories. The double-D symbol is trademarks of Dolby Laboratories, Inc. All rights reserved. CAUTION: VISIBLE AND INVISIBLE LASER RADIATION WHEN OPEN, AVOID EXPOSURE TO BEAM. 1-3 Solder Joint 1-4Lead-Free requirement for service INDENTIFICATION: Regardless of special logo (not always indicated) One must treat all sets from 1.1.2005 onwards, according next rules. Important note: In fact also products a little older can also be treated in this way as long as you avoid mixing solder-alloys (leaded/ lead-free). So best to always use SAC305 and the higher temperatures belong to this. Due to lead-free technology some rules have to be respected by the workshop during a repair: Use only lead-free solder alloy Philips SAC305 with order code 0622 149 00106. If lead-free solder-paste is required, please contact the manufacturer of your solder-equipment. In general use of solder-paste within workshops should be avoided because paste is not easy to store and to handle. Use only adequate solder tools applicable for lead-free solder alloy. The solder tool must be able o To reach at least a solder-temperature of 400°C, o To stabilize the adjusted temperature at the solder-tip o To exchange solder-tips for different applications. Adjust your solder tool so that a temperature around 360°C 380°C is reached and stabilized at the solder joint. Heating-time of the solder-joint should not exceed 4 sec. Avoid temperatures above 400°C otherwise wear-out of tips will rise drastically and flux-fluid will be destroyed. To avoid wear-out of tips switch off un-used equipment, or reduce heat. Mix of lead-free solder alloy / parts with leaded solder alloy / parts is possible but PHILIPS recommends strongly to avoid mixed solder alloy types (leaded and lead-free). If one cannot avoid, clean carefully the solder-joint from old solder alloy and re-solder with new solder alloy (SAC305). Use only original spare-parts listed in the Service-Manuals. Not listed standard-material (commodities) has to be purchased at external companies. Special information for BGA-ICs: - always use the 12nc-recognizable soldering temperature profile of the specific BGA (for de-soldering always use highest lead-free temperature profile, in case of doubt) - lead free BGA-ICs will be delivered in so-called dry-packaging (sealed pack including a silica gel pack) to protect the IC against moisture. After opening, dependent of MSL-level seen on indicator-label in the bag, the BGA-IC possibly still has to be baked dry. This will be communicated via AYS-website. Do not re-use BGAs at all. For sets produced before 1.1.2005, containing leaded soldering-tin and components, all needed spare-parts will be available till the end of the service-period. For repair of such sets nothing changes. On our website: www.atyourservice.ce.Philips.com You find more information to: BGA-de-/soldering (+ baking instructions) Heating-profiles of BGAs and other ICs used in Philips-sets You will find this and more technical information within the “magazine”, chapter “workshop news”. For additional questions please contact your local repair-helpdesk. Notes 1-5Repair Scenario Matrix DVP3600X /77 Main Board C/M Front&Power&USB Board C/M *M:Module Level Repair *C:Component Level Repair *X:UsedType/Versions Board in used PCB Location: 1-6Mechanical and Dismantling Instructions Dismantling Instruction The following guidelines show how to dismantle the player. Step1: Remove 5 screws around the Top Cover, and then remove the Top Cover (Figure 1). Figure 1 Step2: If it is necessary to dismantle Loader or Front Panel, the Front door should be removed first. (Figure 2) Note: Make sure to operate gently otherwise the guider would be damaged. Figure 2 2-1 Please kindly note that dismantle the front door assembly carefully to avoid damage tray and the front door. Detailed information please refer to the model set. The sample is DVP3880K/98.Mechanical and Dismantling Instructions Dismantling Instruction Step3: If the tray cant open in normal way, you can make it through the instruction as below (Figure 3). Note: Make sure to operate gently otherwise the guider would be damaged. Figure 3 Step4: Dismantling Front Panel, disconnect the connectors (XP5, XP6,XP7), need release 4 snaps of Front Panel & 2 snaps of bottom cabinet , then gently pull the Panel out from the set. (Figure 4 - Figure 6) Figure 4 2-2 Detailed information please refer to the model set.2-3 Mechanical and Dismantling Instructions Dismantling InstructionFigure 5 Figure 6 Detailed information please refer to the model set. Step6: Dismantling Main Board, first disconnect the connector (XP1), and then remove 5 screws. (Figure 6) Step7: Remove the 4 screws on Power Board to dismantle the Power Board. (Figure 6) Step5: Dismantling Loader, disconnect the 3 connectors (XP2, XP3, XP4) aiming in the below figure, and remove 1 screw that connects the loader and the bottom cabinet. (Figure 5) Software upgrade Preparation to upgrade software 1) Start the CD Burning software and create a new CD project (Data Disc) with the following setting: B. Read out the software versions to confirm upgrading Label: DVP3XXX (No need the label name) File Name: DVPXXXX_XX.BIN 1) Power on the set and press button on the Power on the set and open the tray, then press remote control. to check the File Name. 2) Press button. The software version and other information are display Note: It is required capital letter for the File System on the TV screen as follows: name. Version XX.XX.XX.XX (Main version) 2) Burn the data onto a blank CDR SUB-VER XX.XX.XX.XX (software version of application software) A. Procedure for software upgrade: 8032 XX.XX.XX.XX 1) Power on the set and insert the prepared Upgrade Servo XX.XX.XX.XX (software version of servo) CDR. RIS XX.XX.XX.XX 2) The set will starts reading disc & response with the DSP XX.XX.XX.XX following display TV screen: Region Code X Upgrade File DETECTED Upgrade? Press Play TO START. 3) Press button to confirm, then screen will display : Files coping Caution: The set must not be power off during UPGRADING upgrading, Otherwise the Main board will be 4) The upgraded tray will automatically open when files damaged entirely. coping complete, then take out the disc. 5) About 1 minute later, the trace will automatically close when upgrading complete. 3-1 4-1 Spindle motor does not move Yes No No Yes Check whether “M5V” (+5V) voltage is normal. Correct connection Check the M5V power supply Check/ Replace U1 Check/Replace the loader,or the bad part. Yes No Go Check the FFC connection between 24PIN and the loader. 1.Whether the R12 is eroded or badly soldered. 2.Whether peripheral components between U1 and xp5 are eroded or badly soldered. Trouble shooting chart Motor no move

    注意事项

    本文(Philips-DVP-3600-X-Service-Manual电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2023 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开