Philips-MCD-130-Service-Manual电路原理图.pdf
1 DVD Micro Theater MCD130 MCD130/93 MCD130/96Service Manual TABLE OF CONTENTS Page ·How to remove the CD manually from the tray.2 ·How to check the return Unit. .3-6 ·Software Upgrade.7 ·How to select right language.8 ·Block diagram .9-1 · Wiring diagram.9-2 ·Main board Circuit diagram.9-3.9-8 Layout diagram9-9.9-10 ·Exploded diagram 9-11 ·Revision List.10 Service Manual ©Copyright 2012 Philips Consumer Electronics B.V. Eindhoven, The Netherlands All rights reserved. No part of this publication may be reproduced, stored in aretrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips. Published by by MTC-FK 1209 AV System Printed in The Netherlands Subject to modification PHILIPS3141 785 34620Version 1.02.0 SAFTETY INSTRUCTIONSGB WARNINGAll ICs and many other semi-conductors aresusceptible to electrostatic discharges (ESD).Careless handling during repair can reduce lifedrastically.When repairing, make sure that you areconnected with the same potential as the massof the set via a wrist wrap with resistance.Keep components and tools also at thispotential.FATTENTIONTous les IC et beaucoup dautressemi-conducteurs sont sensibles auxdécharges statiques (ESD).Leur longévité pourrait être considérablementécourtée par le fait quaucune précaution nestprise à leur manipulation.Lors de réparations, sassurer de bien être reliéau même potentiel que la masse de lappareil etenfiler le bracelet serti dune résistance desécurité.Veiller à ce que les composants ainsi que lesoutils que lon utilise soient également à cepotentiel.ESDD WARNUNGAlle ICs und viele andere Halbleiter sindempfindlich gegenüber elektrostatischenEntladungen (ESD).Unsorgfältige Behandlung im Reparaturfall kandie Lebensdauer drastisch reduzieren.Veranlassen Sie, dass Sie im Reparaturfall überein Pulsarmband mit Widerstand verbundensind mit dem gleichen Potential wie die Massedes Gerätes.Bauteile und Hilfsmittel auch auf dieses gleichePotential halten.NL WAARSCHUWINGAlle ICs en vele andere halfgeleiders zijngevoelig voor electrostatische ontladingen(ESD).Onzorgvuldig behandelen tijdens reparatie kande levensduur drastisch doen verminderen.Zorg ervoor dat u tijdens reparatie via eenpolsband met weerstand verbonden bent methetzelfde potentiaal als de massa van hetapparaat.Houd componenten en hulpmiddelen ook opditzelfde potentiaal.I AVVERTIMENTOTutti IC e parecchi semi-conduttori sonosensibili alle scariche statiche (ESD).La loro longevità potrebbe essere fortementeridatta in caso di non osservazione della piùgrande cauzione alla loro manipolazione.Durante le riparazioni occorre quindi esserecollegato allo stesso potenziale che quello dellamassa dellapparecchio tramite un braccialettoa resistenza.Assicurarsi che i componenti e anche gli utensilicon quali si lavora siano anche a questopotenziale.“Pour votre sécurité, ces documentsdoivent être utilisés par des spécia-listes agréés, seuls habilités à réparervotre appareil en panne”.GBSafety regulations require that the set be restored to its originalcondition and that parts which are identical with those specified,be used.NLVeiligheidsbepalingen vereisen, dat het apparaat bij reparatie inzijn oorspronkelijke toestand wordt teruggebracht en dat onderdelen,identiek aan de gespecificeerde, worden toegepast.FLes normes de sécurité exigent que lappareil soit remis à létatdorigine et que soient utiliséés les piéces de rechange identiquesà celles spécifiées.DBei jeder Reparatur sind die geltenden Sicherheitsvorschriften zubeachten. Der Original zustand des Geräts darf nicht verändert werden;für Reparaturen sind Original-Ersatzteile zu verwenden.ILe norme di sicurezza esigono che lapparecchio venga rimessonelle condizioni originali e che siano utilizzati i pezzi di ricambioidentici a quelli specificati.“After servicing and before returning set to customer perform aleakage current measurement test from all exposed metal parts toearth ground to assure no shock hazard exist. The leakage currentmust not exceed 0.5mA.“CLASS 1LASER PRODUCT3122 110 03420GB Warning !Invisible laser radiation when open.Avoid direct exposure to beam.S Varning !Osynlig laserstrålning när apparaten är öppnad och spärrenär urkopplad. Betrakta ej strålen.SF Varoitus !Avatussa laitteessa ja suojalukituksen ohitettaessa olet alttiinanäkymättömälle laserisäteilylle. Älä katso säteeseen!DK Advarse !Usynlig laserstråling ved åbning når sikkerhedsafbrydere erude af funktion. Undgå udsaettelse for stråling.Caution: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.2-1Whenthepowersupplyisbeingturnedon,youmaynotremovethislasercautionslabel.Ifitremoves,radiationoflasermaybereceived.2.1 ESD PROTECTIONPREPARATIONOFSERVICINGPickupHeadconsistsofalaserdiodethatisverysusceptibletoexternalstaticelectrocity.Althoughitoperatesproperlyafterreplacement,ifitwassubjecttoelectrostaticdischargeduringreplacement,itslifemightbeshortened.Whenreplacing,useaconductivemat,solderingironwithgroundwire,etc.toprotectthelaserdiodeformdamagebystaticelectricity.Andalso,theLSIandICaresameasabove.SolderingironwithgroundwireorceramictypeGroundconductivewriststrapforbody.ConductivematThegroundresistancebetweenthegroundlineandthegroundislessthan101M2-2SAFTY NOTICEPlug the AC line cord directly into a 120V AC outlet (donot use an isolation transformer for this check). Use anAC voltmeter, having 5000 per volt or more sensitivity.Connect a 1500 10W resistor,paralleled by a 0.15uF150V AC capacitor between a knomn good earth ground(water pipe, conduit, etc.) and all exposed metal parts ofcabinet (antennas, handle bracket, metal cabinetscrewheads, metal overlays, control shafts, etc.).SAFTY PRECAUTIONSLEAKAGE CURRENT CHECKMeasure the AC voltage across the 1500 resistor.The test must be conducted with the AC switch on andthen repeated with the AC switch off. The AC voltageindicated by the meter may not exceed 0.3V.A readingexceeding 0.3V indicates that a dangerous potentialexists, the fault must be located and corrected.Repeat the above test with the DVD VIDEO PLAYERpower plug reversed.NEVER RETURN A DVD VIDEO PLAYER TO THECUSTOMER WITHOUT TAKING NECESSARYCORRECTIVE ACTION.READING SHOULD NOT EXCEED 0.3VDVD VIDEO PLAYERAC OUTLETAC VOLTMETERTest all exposed metal.Voltmeter Hook-up for Leakage Current Check0.15uF 150V AC150010W(5000 per voltor more sensitivity)Good earth groundsuch as a water pipe,conduit, etc.The lightning flash with arrowhead symbol, within anequilateral triangle, is intended to alert the user to thepresence of uninsulated “dangerous voltage“ within theproduct's enclosure that may be of sufficient magnitude toconstitute a risk of electric shock to persons.The exclamation point within an equilateral triangle isintended to alert the user to the presence of importantoperating and maintenance (servicing) instructions in theliterature accompanying the appliance.2-3MCD130 PRODUCT SPEC Sheet-190 Page 1 of 10 Rev.1.0 MCD130 DVD Micro Theatre Hardware Requirement Specification Valid for stroke version: Stroke Version Countries / Region MCD130 /12 Europe /05 UK /37 USA its publication conveys no license under any patent or other right, nor does the publisher assume liability, for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced, in whole or in part, without the written consent of the publisher.MCD130 PRODUCT SPEC Sheet-190 Page 2 of 10 Rev.1.0 MCD130 DVD Micro Theatre Technical Specifications (Philips Sheet-190) Contents 1. EPICTION . 3 2. ACCESSORIES . 3 3. General Description . 4 4. Safety requirements . 5 5. BSMI requirements . 5 6. CCC requirements . 5 7. PowerSupply . 5 8. Audio (all test with 22k Ohm load unless specified) . 6 9. Speaker (all test with 8 Ohm dummy load) . 6 10. Video Output . 6 11. YUV Video Output . 7 12. Miscellaneous Electrical . 7 13. Playability Requirement (See attached in last page). . 8 DISC Playability (details refer to Playability Test Plan) . 8 Power On / Off Disturbances . 9 14. Mechanical Specification (Refer PQR or PQP) . 10 15. Critical component . 10 16. Cosmetic Specification . 10 17. Change History . 10 Acceptance Status Version: 1 Department Development PS Vol=Max - =30dB 9. Channel balance 1kHz 0dB +/- 2dB DVD Dolby 1.5 10. Video Output AV output ports special requirement >10V DC No component damaged Connection Port Impedance 75 ohm