欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Dynacord-CL1600-pwr-ti维修电路图 手册.pdf

    • 资源ID:94419       资源大小:530.97KB        全文页数:4页
    • 资源格式: PDF        下载积分:8积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Dynacord-CL1600-pwr-ti维修电路图 手册.pdf

    BESCHREIBUNG Die neuen Endstufen der Compact Linear Precision Serie vereinen berragende Audio-Performance mit hchster Zuverlssigkeit und Betriebssicherheit bei gleichzeitig deutlich geringerem Gewicht. Durch die Verwendung optimierter Netzteile mit besonders streuarmen Ringkerntransformatoren und die konsequente Anwendung der Class H Technologie (CL 800 Class AB) wird ein groer Headroom oberhalb der ausgewiesenen Nennleistung erzielt und gleichzeitig eine deutliche Reduzierung von Gewicht und Verlustleistung erreicht. Endstufen der CL-Serie erfllen auch die extremen Anforderungen des harten Tour-Betriebs. Sie sind gegen berhitzung, berlast, Kurzschluss sowie Hochfrequenz und Gleichspannung am Ausgang zuverlssig geschtzt. Beim Softstart werden die Leistungsausgnge ber Relais verzgert zugeschaltet. Zustzlich verhindert eine Einschaltstrombegrenzung das Ansprechen von Netzsicherungen. DYNACORD Endstufen berwachen stndig das Ausgangssignal gegen das Eingangssignal mittels superschneller Audio-Prozessoren, die im Falle eines nichtlinearen Betriebszustandes Control-Parameter an die Limiter senden. Die Limiter arbeiten dynamisch und beschrnken nicht den Dynamik- Umfang, da sie den Eingangs-Level regeln. Die thermische Stabilitt wird durch zwei 3-Stufen Lfter mit sehr niedrigem Geruschpegel gewhrleistet. Die Eingnge sind elektronisch symmetriert auf XLR Buchsen gefhrt und Direct-Outs zum Durchschleifen des Signals sind ebenfalls Standard. Die Spannungsverstrkung aller Modelle ist auf 32dB (Constant Gain) eingestellt. ber das Input Routing knnen die Betriebsarten Mono oder Stereo gewhlt werden. Auerdem ist der Mono- Bridged” Betrieb ber die separate Bridged-Out Buchse und den Bridged-Mode Umschalter sehr einfach zu realisieren. Auf der Frontseite befinden sich die in dB skalierten Levelsteller, die als besonders przise, bediensichere Rastpotis ausgefhrt und zum Schutz vor mechanischer Beschdigung in der Frontblende versenkt sind. Eine schnelle bersicht ber den aktuellen Betriebszustand der Endstufen vermittelt das leicht ablebare LED-Display mit Anzeige von Power, Protect, Signal-Anzeige und Limit. Die Leistungsausgnge fr Channel A und B sowie der Bridged-Out sind als zuverlssige Speakon-Buchsen ausgefhrt. Ebenfalls auf der Rckwand befindet sich ein Groundlift-Schalter, der bei Bedarf das Gehuse von der Schaltungsmasse trennt um Brummschleifen zu verhindern. Alle CL-Endstufen knnen im Normalbetrieb an Lasten bis hinab zu 2 Ohm und im Brckenbetrieb bis zu minimal 4 Ohm absolut betriebssicher eingesetzt werden. Fr den Einbau in Gestellschrnken oder Transportracks sind verschieden lange Rear-Rackmount Schienen optional erhltlich. Technische Informationen Architects and engineers specifications CL 800 CL 1200 CL 1600 CL 2000 Power Amplifiers DESCRIPTION The new Compact Linear Precision Series power amplifiers combine outstanding audio performance with maximum reliability and operating security as well as being markedly lighter than equivalent power amplifiers. Through the use of an optimized power supply with low dispersion toroidal transformers as well as of Class H technology (CL 800 Class AB), a large amount of headroom above the specified nominal output has been achieved along with a considerable reduction in weight and thermal leakage. CL Series power amplifiers satisfy all the criteria for punishing on the road use. They are reliably protected against overheating, overload and short-circuits as well as high frequency and DC at the output. The soft start function employs relays to insert a delay between switching on the device and the activation of the power outputs. A further circuit limits the current on power-up, there-by protecting the mains fuses. DYNACORD amplifiers constantly monitor the input- versus the output- signal by means of super-fast audio processors which send -in case of non-linear operation- control parameters to the limiters. The limiters are thus operating dynamically and do not affect the amplifiers dynamic capabilities as they control the input gain level. Thermal stability is provided by a 3-stage fan with a very low noise level. The inputs are electronically balanced and implemented on XLR connectors, whilst Direct Outs for looping the signal are also standard. Input routing permits the choice between Mono and Stereo modes. Mono bridged mode is also easy to realize thanks to the separate Bridged Out connectors and the Bridged Mode switch. The level controllers on the front panel are scaled in decibels and implemented as highly precise and rugged detent potentiometers recessed into the front panel to protect them from mechanical damage. The clearly laid out LED display shows the operating condition of the power amplifiers by means of Power, Protect, Signal and Limit indicators. The electronically balanced XLR input and output connectors with a sensitivity of +4dBu (1.23V) are designed for direct operation with professional mixing consoles and signal processors. The power outputs for Channels A and B as well as the Bridged Out are available on reliable Speakon connectors. There is also a Ground Lift switch on the rear panel to separate the signal ground from the chassis ground to eliminate ground loops. All CL power amplifiers can normally be operated with loads as low as 2 ohms and in bridged mode down to a minimum of 4 ohms with complete operational security. CL800 2 x 400W RadioFans.CN CL800CL1200CL1600CL2000 Load Impedance 2 4 8 2 4 8 2 4 8 2 4 8 Max. Midband Output Power THD = 1%, 1kHz , Dual Channel 600W400W240W900W600W350W1100W800W500W1500W1000W600W Rated Output Power THD < 0,1%, 20Hz 20kHz -300W150W-500W250W-700W350W-850W450W Max. Single Channel Output Power Dynamic Headroom, IHF-A 1100W580W300W1450W 850W 450W2200W1200W 625W2700W 1450W 750W Max. Single Channel Output Power Continuous, 1kHz 800W480W270W1200W720W410W1500W950W550W1900W1150W650W Max. Bridged Output Power THD = 1%, 1kHz -1200W800W-1800W1200W-2200w1600W-3000W2000W Maximum RMS Voltage Swing THD = 1%, 1kHz 50V62V72V80V Power Bandwith, ref. 1kHz THD =1%, half power 4 ohms 10Hz 60kHz Voltage Gain, ref. 1kHz 32,0 dB Input Sensitivity at rated output power +1,15 dBu (0,88 V rms)+3,2 dBu (1,12 V rms)+4,7 dBu (1,33 V rms)+5,5 dBu (1,46 V rms) THD at rated output power MBW = 80kHz, 1kHz < 0,05% IMD-SMPTE, 60Hz, 7kHz < 0,02% DIM 30, 3,15kHz, 15kHz < 0,01% Maximum Input Level +22 dBu (9,76 V rms) Crosstalk ref. 1kHz, at rated output power 300 Slew Rate25 V/s 30 V/s 35 V/s 35 V/s Signal to Noise Ratio, Amplifier A-weighted 103,5 dB105,5 dB107,0 dB109,0 dB Output Noise, A-weighted < -70 dB Output Stage Topology Class ABClass HClass HClass H Power Requirements 100V, 120V, 220V, 230V, 240 V; 50Hz 60Hz (factory configured) Power Consumption 1/8 max. output power 4 ohms 600W *500W *660W *725W Protections Audio limiters, High temperature, DC, HF, Back-EMF, Peak current limiters, Inrush current limiters, Turn on delay Cooling Front-to rear, 3-stage fans Ambient Temperature Limits+5C . +40C (40F . 105F) Safety Class I Dimensions (W x H x D) mm483 x 88,1 x 386,8 Weight 13,5 kg (30,8 lbs)15 kg (33 lbs) 16 kg (35,2 lbs)18 kg ( 39,6 lbs) Optional: Rear-rackmount 15,5“ Rear-rackmount 18“ LPN + Lo-Cut internal filter-card D112930 (NRS 90262) D112933 (NRS 90264) D112963 (NRS 90268) - Amplifier at rated conditions, both channels driven, 8 loads, unless otherwise specified. * Measured with 110% of reated mains voltage Notes: - Depending on the ambient temperature, the unit might not operate continuously at 2 load in Dual Mode or 4 load in Bridged Mode. SPECIFICATIONS RadioFans.CN BLOCK DIAGRAM RadioFans.CN USA Telex Communications Inc., 12000 Portland Ave. South, Burnsville, MN 55337, Phone: +1 952-884-4051, FAX: +1 952-884-0043 Germany EVI AUDIO GmbH, Hirschberger Ring 45, D 94315, Straubing, Germany Phone: 49 9421-706 0, FAX: 49 9421-706 265 Subject to change without prior notice. Printed in Germany 10/01/2006 / 361 910 www.dynacord.de RadioFans.CN

    注意事项

    本文(Dynacord-CL1600-pwr-ti维修电路图 手册.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2023 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开