欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Philips-DVD963SA-dvd-sm维修电路原理图.pdf

    • 资源ID:97696       资源大小:13.39MB        全文页数:96页
    • 资源格式: PDF        下载积分:25积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Philips-DVD963SA-dvd-sm维修电路原理图.pdf

    Published by MW 0271 Service PaCEPrinted in the NetherlandsSubject to modificationEN 3122 785 12331 Copyright 2002 Philips Consumer Electronics B.V. Eindhoven, The Netherlands. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips. DVD-Video PlayerDVD963SA DVD963SA /001 /171 /691 CL 26532105_000.eps 280802 ContentsPageContentsPage 1Technical Specs and Connection Facilities2 2Safety Instructions, Warnings, and Notes3 3Directions for Use4 4Mechanical-, Dismantling Instructions, and Service Hints18 5Diagnostic Software, Trouble Shooting and Test Instructions21 6Block-, Wiring Diagram and Testpoint Overview Block Diagram41 Wiring Diagram42 Testpoint Overviews43 7Electrical Diagrams and Print-LayoutsDiagram PWB Power Supply Unit46 AV Board: SYS Clk if it is, press OPEN/CLOSE, if it is not, press STOP. By pressing PLAY the script will proceed to the next test. If the user presses PLAY before OPEN/CLOSE or STOP, the DispLed nucleus will return TRUE (LED test successful). 5.3.3Keyboard Test The keyboard of the DVD player is tested by nucleus DispKeyb. The user is expected to press all keys on the local keyboard once. The code of the key pressed is shown on the local display (1 hexadecimal digit) immediately followed by a (hexadecimal) number indicating how many times that key has been pressed. Example of the local display during this test: Figure 5-7 The key-codes displayed on the local display will scroll from right to left when the display gets full, the text K will remain on display. Figure 5-8 If any keys are detected more than once (due to hardware error), the key-code is displayed twice (or more), with the second digit increased by 1. If the user does not press all keys minimally once (in any order), the DispKeys nucleus will return FALSE and cause an error in the overall result of the player script. The user can leave the keyboard test by pressing the PLAY key on the local display of the DVD player for at least one full second. The result of the keyboard test is shown on local display as follows: Figure 5-9 Or Figure 5-10 Pressing PLAY on the local keyboard again will proceed to the next text. 5.3.4Remote Control Test The remote control of the DVD player is tested by nucleus DispRc. The user must press any key on the remote control just once. The codes of the key pressed will be shown on the local display in hexadecimal format. Example: Figure 5-11 In this example 23 is the hexidecimal code of the pressed RC key. The user can leave the remote-control test by pressing PLAY on the local keyboard of the DVD player. The remote control test is successful if a code was received before the user If OK, press OPEN/CLOSE If OK, press OPEN/CLOSE If OK, press OPEN/CLOSE If NOK, press STOP If NOK, press STOP If NOK, press STOP press PLAY to continue CL 16532162_031.eps 080102 CL 196532162_032.eps 080102 KEY IDKEY 0PLAY 1STOP 2OPEN/CLOSE 3STANDBY 4NEXT 5PREVIOUS 6PAUSE 7AUDIO DIRECT ESOUND MODE FREPEAT CL 26532105_057.eps 300802 CL 16532162_033.eps 080102 CL 16532162_034.eps 080102 CL 16532162_035.eps 140102 RadioFans.CN 收音机爱 好者资料库 Diagnostic Software, Trouble Shooting and Test InstructionsEN 24DVD963SA5. pressed the PLAY key. Pressing the PLAY key, before pressing a key on the remote control, gives an error in the remote control test (note that the remote control test will also fail if a key on the remote control was pressed but no code was received). The remote control test does not check upon the contents of the received code, that is it will not be checked if the received code matches the key pressed. If desired, the user can manually check this code by using a code-table for the remote control key-codes. Figure 5-12 After pressing PLAY, the result of the remote control test is displayed on the local display of the DVD player as follows: Figure 5-13 Or Figure 5-14 Pressing PLAY on the local keyboard again will proceed to the next test. 5.3.5P50 Loop-Back Test For the P50 loop-back test, the user must first press a key to decide if the test is to be performed. The display will show the following message: Figure 5-15 If the user presses STOP, the P50 test will be skipped. If the user presses OPEN/CLOSE, the P50 test is performed and the result is displayed as follows: Test successful: Figure 5-16 Test fails: Figure 5-17 Press the PLAY key to continue to the next text RC Key id Hexadecimal code STANDBY0C 11 22 33 44 55 66 77 88 99 00 RETURN83 DISPLAYEF DISC MENU54 SYSTEM MENU82 CURSOR UP58 CURSOR DOWN59 CURSOR LEFT5A CURSOR RIGHT5B OK5C PREVIOUS21 NEXT20 STOP31 PLAY2C PAUSE30 SUBTITLE4B ANGLE85 ZOOMF7 AUDIO4E REPEAT1D REPEAT A-B3B SHUFFLE1C SCAN2A CL 16532162_037.eps 080102 CL 96532065_013.eps 120799 CL 96532065_014.eps 120799 CL 16532007_004.eps 090102 CL 16532007_005.eps 090102 CL 16532007_006.eps 090102 RadioFans.CN 收音机爱 好者资料库 Diagnostic Software, Trouble Shooting and Test InstructionsEN 25DVD963SA5. 5.4Mono PCB Digital Part 5.4.1Picture Test The picture test is performed by putting a predefined picture (colour bar) on the display (nucleus VideoColDencOn), and asking the user for confirmation. The display will show the following message: Figure 5-18 By pressing OPEN/CLOSE the user confirms the test, pressing STOP will indicate the picture was invisible or incorrect. Pressing PLAY will proceed to the next test. If the user presses PLAY without pressing OPEN/CLOSE or STOP first, the result of this test will be TRUE (picture ok). Note: The colour bar must be simultaneously available on the CVBS, YC, and RGB (or YUV) outputs available. On the SCART only the CVBS and RGB signals will be available. 5.4.2Sound 1 note that this test will not contribute to the test result of the Basic Engine. Pressing PLAY proceeds to the next test, after the disc motor has been shut off with a call to nucleus BeDiscMotorOff. 5.5.8Tray Test As a last action for the Basic Engine tests, the tray test is repeated. The local display will look as follows: Figure 5-29 This test is meant to give the user the opportunity to remove the disc in the tray. The tray position can be toggled using the OPEN/CLOSE key. The tray will be closed (by the software, if it is open) before proceeding to the next test when the user presses the PLAY key. 5.5.9Error Log (See Table on Page 25) Reading the error log and error bits information can be useful to determine any errors that occurred recently during normal operation of the DVD player. Reading the error log is done by nucleus LogReadErr. The display during the errorlog readout looks as follows : Figure 5-30 Note: Previous versions of the diagnostic software showed a 8- digit error code. Due to limitations in the number of digits that can be displayed by some front panel displays, the most significant digits will not be shown. This can be done since all the error codes used by this player has set these 2 digits to “00” By pressing OPEN/CLOSE or STOP the user can move forward or backward (respectively) through the logged error codes. If 0000 is displayed at all positions, the error log is empty. Display of the logged errors is done in a cyclic manner. By pressing PLAY on the local keyboard, the user can proceed to the next test. 5.5.10 Error Bits Reading the error bits is done by nucleus LogReadBits. The display during the errorbits readout looks as follows: Figure 5-31 Only the identification number (decimal) representing set errorbits will be shown. By pressing OPEN/CLOSE or STOP, the user can move forward or backward (respectively) through the logged errorcodes. If the display only shows EB-0, no error bits were set. By pressing PLAY the user can continue to the next test. 5.6Loop Test (See Table Below) At the start of the loop test, the local display of the DVD player will show the interactive player test result readout in the following display: Figure 5-32 The left side of the display contains a 3-digit code, which can have a value between 000 and 111. These values indicate the faulty modules and are to be interpreted as follows: Figure 5-33 The loop test will perform the same nuclei as the dealer test, but it will loop through the list of nuclei indefinitely. The display of the DVD player will display not only the three digits indicating correct/faulty modules and the last found error code (as mentioned, faults are detected as far as they can be within the scope of the diagnostic software), but also a loop counter indicating how many times the loop has been gone through. If an error was detected, the display will remain as in figure 5-34 until the user presses the PLAY key and then it will continue to the next loop. Example: Figure 5-34 The 2-digit number (23) on the right of figure 5-32 indicates the number of times the loop test has been performed. CL 16532162_046.eps 080102 CL 16532162_041.eps 080102 CL 16532162_047.eps 080102 CL 16532162_048.eps 080102 CL 16532162_049.eps 080102 Displayed Value Indication for each module Basic EngineMono PCB Display PCB 000okokok 001okokfaulty 010okfaultyok 011okfaultyfaulty 100faultyokok 101faultyokfaulty 110faultyfaultyok 111faultyfaultyfaulty CL 96532065_031.eps 120799 CL 16532162_050.eps 080102 RadioFans.CN 收音机爱 好者资料库 Diagnostic Software, Trouble Shooting and Test InstructionsEN 28DVD963SA5. After one loop cycle: Display the 3-digit module bits together with the last error code which occured in the loop test. The 4 digits at the right side of the display (fig. 5-34) show the last error that was found during the loop test. The leftmost two digits (54) of this code indicates which nucleus resulted in a fault. The rightmost two digits (03) refer to the faultcode within that nucleus. For further explanation of this error code, refer to chapter 5.8 (Nuclei Error Codes). 5.6.1Errorlog Explanation: The application errors will be logged in the NVRAM. The maximum number of error bytes that will be visible is 16. The first word (4 digits) of the byte is the component identification, the last word is the error code. The diagnostics software will present a combination of this component identification plus an error code on the local display (and on the attached terminal). The last reported error is shown as and the errors in between as . The devices that may report errors are the serial controller (UART), the basic engine (BE), the slave processor (SLPH), the SACD Stream Manager (SSM) and the SACD Media Access (SMA). The identification of these components is as follows: The tables in the next chapters list the error code and corresponding problem. The column Explanation holds a more elaborate description and the most likely reason for the error. Some Examples: 002E0000 (SMA reported a timeout error) 0016010A (Engine could not fully close or open the tray) D0010001 (Flash checksum failed). For further explanation of DS errors, see description of nucleui error codes in paragraph 5.8. UART Error Codes BE Errors SLPH Error Codes SSM Error Codes Component nameComponent identification Serial controller (UART)000A Engine (BE)0016 Slave Processor (SLPH)001A SACD Stream Manager (SSM) 001C SACD Media Access (SMA)002E Diagnostic software (DS)Dxxx Error Number Error nameExplanation 0000BUF_OVE RFLOW To many characters were offered in too little time. Reason: system was too busy doing other jobs. 0001COMMUNI CATION Usually a protocol error. Reason: bad connection between engine and processor. 0002TIME OUT Error Number Error nameExplanation 0101S2B_ILL_CO MMAND Parameter(s) not valid for this command. Reason: some communication problem between UART and engine. 0102S2B_ILL_PAR AM Command not allowed in this state or unknown. Reason: see S2B_ILL_COMMAND error 0103S2B_SLEDGE Sledge could not be moved to home position. 0104S2B_FOCUSFocus failure 0105S2B_MOTORMotor could not reach speed within timeout 0106S2B_RADIALServo didnt get on track after several retries. 0107S2B_PLL_LO CK PLL could not lock in Accessing or Tracking state 0108SBC_HEADE R_TO Header timeout 0109S2B_SBC_NO T_FOUND Requested subcode item could not be found. 010AS2B_TRAYTray could not be opened or closed completely. 010BS2B_TOC_RE AD TOC could not be read within timeout period. 010CS2B_JUMPRequested seek could not be performed. 010DS2B_NON_EX IST_SES Attempt to access a non-existing session. 010ES2B_NON_EX IST_BCA Caller tries to acces a non- existing BCA area 010FSpeed settingA wrong or inappropraiate speed value has been set 0116NO_DISCNo disc selected 011ATRAY_INITAfter reset, initialized tray 011BNO TOC INFO No TOC information in lead-in area or erase TOC found 01F0S2B_OVERR UN Too many bytes received over S2B Reason: see S2B_ILL_COMMAND error 01F1S2B_COMM_ TO Not enough bytes are received over S2B Reason: see S2B_ILL_COMMAND error 01F2S2B_PARITYByte received with parity error. Reason: see S2B_ILL_COMMAND error 01F3S2B_ILL_PHA SE CMD IDC is not valid, transmission out of sync. Reason: see S2B_ILL_COMMAND error 01F4S2B_ILL_NR_ OF_BYTES Byte count has an illegal value. Reason: see S2B_ILL_COMMAND error Error Number Error nameExplanation 0000COMMUNICA TION Error in I2C communication. Reason: bad connection between slave processor and main processor. Error CodeError nameExplanation 0006SP_SYNCER ROR System cannot get synchronised with sectors coming from disc. Reason: Usually a damaged disc or the player was dropped/ pushed during operation. If not, the engine is malfunctioning. 0007SP_EDCERR OR Data coming from disc is damaged. Reason: see SP_SYNCERROR Error Number Error nameExplanation RadioFans.CN 收音机爱 好者资料库 Diagnostic Software, Trouble Shooting and Test InstructionsEN 29DVD963SA5. SMA Error Codes 5.6.2Reprogramming of New Mono Boards. Figure 5-35 Reprogamming code 0008SP_CONTINU ITYERROR Sequence of sectors coming from disc is incorrect. Reason: see SP_SYNCERROR 0009DMX_CONTI NUITYERRO R Sequence of sectors is incorrect. Reason: problem with buffer RAM 000ALLD_ERRORAn illegal audio format was offered to the decoder. Reason: unknown audio type on disc or problem with buffer RAM 000BBCU_ERRORInternal problem in Furore chip Error CodeError nameExplanation Error NumberError nameExplanation 0000SMA_TIMEO UTERROR Data coming from disc not in time. Reason: damaged disc or engine problem. Caution This information is confidential and may not be distributed. Only a qualified service person should reprogram the mono board. After reset of NV-memory or repair of the mono board, all the customer settings and also the region code will be lost. Reprogramming of the mono board will put the player back in the state in which it has left the factory, i.e. with the default settings and the allowed region code. Reprogramming will be done by way of the remote control. Put the player in stop mode, no disc loaded. Reprogramming is limited to 25 times When the counter reaches 25, reprogramming is not possible anymore Press the following keys on the rem

    注意事项

    本文(Philips-DVD963SA-dvd-sm维修电路原理图.pdf)为本站会员()主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2023 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开