欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 欧美收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • 功放/音响/收扩>
  • 仪器仪表>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 老电视>
  • 乐器/演出设备类>
  • ImageVerifierCode 换一换

    Biddle L1050_UG 电路图.pdf

    • 资源ID:200384       资源大小:400.90KB        全文页数:25页
    • 资源格式: PDF        下载积分:10积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Biddle L1050_UG 电路图.pdf

    Instruction Manual AVTM651050 for L1050 Portable Locator Catalog No. 651050 High Voltage Equipment Aparato de Alto Voltaje Read the entire manual before operating. Antes de operar este producto lea este manual enteramente. AVO International 510 Township Line Road Blue Bell, PA 19422 U.S.A. (215) 646-9200 RadioFans.CN 收音机爱 好者资料库 L1050 Portable Locator Instruction Manual Copyright March 1998 by AVO International All rights reserved. Reproduction without written permission is prohibited. Specifications are subject to change without notice. RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 ii TABLE OF CONTENTS SectionPage 1Introduction.1 Receiving Instructions.1 General Information.1 2Safety.2 3Specifications.4 4Setup and Operation.5 Controls and Indicators.5 Select the Locating Method.6 Multiple Grounded Circuit.7 Flexible Coupler Connection.9 Inductive Connection.10 Direct Connection.11 Notes on Selecting the Tracing Signal.12 Continuously Grounded Circuit.13 Telephone Direct Shield Connection.14 Telephone Direct Pair Connection .15 5Locating the Cable or Pipe.16 Procedure Using Peaking Antenna.16 Depth Measurements 70% Method .18 Depth Measurements Straight Lift Method.19 6Service.20 Maintenance.20 Repair.20 Warranty.21 LIST OF ILLUSTRATIONS Figure 1Transmitter Controls and Indicators.5 2Receiver Controls and Indicators.5 3Multiple Grounded CATV or Power Enclosure Connection.7 4Multiple Grounded Secondary Circuit Connection.8 5Multiple Grounded Telephone Pedestal Cover Connection.8 6Flexible Coupler Connection.9 7Inductive Connection.10 8Direct Connection.11 9Continuously Grounded Circuit, Cable, Pipe, or Conduit.13 10Telephone Direct Shield Connection.14 11Telephone Direct Pair Connection .15 12Receiver Meter Readings .16 13Depth Measurement Using the 70% Method.18 14Depth Measurement Using the Straight Lift Method. 19 1 Section 1 Introduction Receiving Instructions Check the equipment received against the packing list to ensure that all materials are present. Notify AVO International of any shortage. Telephone (215) 646-9200 and ask for the customer service department. Examine the instrument for damage received in transit. If damage is discovered, file a claim with the carrier at once. Prepare a detailed description of the damage and notify AVO International. This instrument has been thoroughly tested and inspected to meet rigid specifications before being shipped. It is ready for use when set up as indicated in this manual. General Information Thanks for purchasing the BIDDLE L1050 Portable Locator. The portable locator will help you detect and trace the routes of buried power cables, CATV cables, gas and water pipes, sewer lines, telephone cables, and fiber-optic cables. The transmitter applies a tracing signal onto a cable or pipe. The receiver detects the tracing signal and indicates how strong it is. You can locate the path of a buried pipe or cable by following the tracing signal. Supplied Components 1.Transmitter unit (built into carrying case) 2.Receiver unit 3.Red/black test cord 4.Ground rod 5.Instruction Manual 6.Eight AA-size alkaline batteries 7.Eight D-size batteries Optional Flexible Coupler Preparation for Use Remove the receiver from the case, and turn it face-down. Locate the battery compartment on the back of the receiver. Install the eight AA-size batteries as marked on the case. 2 The transmitter battery compartment is situated under the receiver storage well, in the bottom of the case. Install the eight D-size transmitter batteries as marked on the case. Section 2 Safety The L1050 Portable Locator and the recommended operating procedures have been designed with careful attention to safety; however, it is not possible to eliminate all hazards from electrical test equipment or to foresee every possible hazard that may occur. It is therefore essential that the user, in addition to following the safety rules in this manual, also carefully consider all safety aspects of the test before proceeding. Safety is the responsibility of the user. Use suitable barriers, barricades, and warnings to keep people not actually engaged in the test at a safe distance. Make sure that no one can make contact with energized parts of the test equipment and the specimen under test. Treat all terminals of power equipment as a potential electric shock hazard. There is always the possibility of voltages being induced at these terminals because of proximity to energized high-voltage lines or equipment. Always turn the transmitter power off before touching any terminals. Always disconnect test leads from the cable under test before attempting to disconnect them from the portable locator. Never connect the test leads to a cable that does not have a safety ground strap in place. Never disconnect the test leads from a cable that does not have a safety ground strap in place. The safety ground connection must be the first made and the last removed. Any interruption of the grounding connection can create an electric shock hazard. Do not use this equipment to fault locate on any cable which is likely to be near enough to an energized cable to allow a burn through of the insulation of the energized cable. This situation may occur when the cables are located in a common trench, duct or tray (for example, three- phase systems). Do not operate the equipment with protective covers removed. Operation without the protective covers presents an electric shock hazard. Use all practical safety precautions to prevent contact with energized parts of the equipment and related circuits. 3 Use the recommended grounding and connection procedures. Make sure that the equipment is grounded properly. Any interruption of the grounding connection can create an electric shock hazard. Refer to IEEE 510-1983 IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing for additional information. Do not use the portable locator or its accessories with any device or for any purpose other than as specifically described in this manual. Misuse of this equipment can be extremely dangerous. Never connect the portable locator to energized equipment. Do not use in an explosive atmosphere. If the portable locator is operated in accordance with the safety precautions described, and if all grounds are correctly made, rubber gloves are not necessary. As a routine safety procedure, however, some users require that rubber gloves be worn, not only when making connections to the high-voltage terminals but also when manipulating controls. AVO International considers this an excellent safety practice. Users of high-voltage equipment should note that high-voltage discharges and other sources of strong electric or magnetic fields may interfere with the proper operation of heart pacemakers. Personnel having heart pacemakers should obtain expert advice on possible risks before using this equipment or being close to equipment while it is in operation. 4 Section 3 Specifications Receiver Operating frequency:82.315 kHz and 815 Hz, switch selectable Antenna mode:Peak responding horizontal antenna Operating and storage temperature range:-4 to +133F (-20 to +55C) Battery type:Eight AA-size alkaline cells Battery life:120 hr on 815 Hz and 100 hr on 82.315 kHz Dimensions:13 x 3 x 3 in (33 x 7.6 x 7.6 cm) (L x W x H) Weight:1 lb, 4 oz (0.568 kg) Transmitter Operating frequency:82.315 kHz and 815 Hz Output power:100 mW directly connected 100 mW inductively coupled Battery type:Eight D-size alkaline cells Battery life:150 hr Operating and storage temperature range:-4 to +133F (-20 to +55C) Dimensions:17 x 7.5 x 6.5 in. (43 x 19 x 16.5 cm) (L x W x H) Weight:6 lb, 3 oz (2.8 kg) 5 Section 4 Setup and Operation Controls and Indicators Follow all safety precautions in Section 2 of this manual. Figure 1:Transmitter Controls and Indicators. Figure 1: Transmitter Controls and Indicators Figure 2: Receiver Controls and Indicators 6 Select the Locating Method Find the heading below that matches your job, then select the locating method. The methods under each heading are listed in order of preference. The first method is easiest, and usually gives the best results. The second method listed is next best, and so on. After selecting the locating method, turn to the page that tells how to connect the equipment. ELECTRICAL CABLE AND CABLE TV (CATV) Multiple Grounded Circuit Flexible Coupler Connection Inductive Connection Direct Connection GAS AND WATER PIPE Continuously Grounded Circuit Flexible Coupler Connection TELEPHONE CABLE Multiple Grounded Circuit Telephone Direct Shield Connection Telephone Direct Pair Connection FIBER-OPTIC CABLES Multiple Grounded Circuit Inductive Connection Telephone Direct Shield Connection NOTE: The flexible coupler and inductive connection methods require using the 82 kHz high frequency setting. 7 Multiple Grounded Circuit This method uses the existing ground points that are already exposed and available to you. It is not necessary to disconnect the service. The range of operation is up to 0.5 mi (0.8km). Connect as shown in Figures 3, 4, and 5. Connect the red test cord to an existing ground point. Place the ground rod approximately 10 ft (3 m) from this point, at an angle of 90 degrees to the buried cable or pipe. Push the ground rod into the ground 8 to 10 in. (20.3 to 25.4 cm). Connect the black test cord to the ground rod. Plug the red/black test cord into the DIRECT CONNECT jack. Set the 815Hz/OFF/82kHz switch to the 815 Hz position. The ON indicator will start blinking. Turn to Section 5, ?Locating the Cable or Pipe.? BLACK TEST CORD RYCOM GROUND ROD TRANSMITTER RED TEST CORD CONNECT TO CATV PEDESTAL COVER OR POWER ENCLOSURE Figure 3: Multiple Grounded CATV or Power Enclosure Connection 8 BLACK TEST CORD RED TEST CORD CASE METER CIRCUIT BREAKER BOX POLE TRANSFORMER HOUSE GROUND RYCOM GROUND TRANSMITTER ROD BURIED ELECTRICAL SERVICE WIRE INDICATES RED TEST CORD ATTACHMENT POINTS Figure 4: Multiple Grounded Secondary Circuit Connection CENTRAL OFFICE RED TEST CORD PEDESTAL COVER BLACK TEST CORD BURIED TELEPHONE CABLE WITH METALLIC BOND TO OTHER CABLES SHIELD TRANSMITTER Figure 5: Multiple Grounded Telephone Pedestal Cover Connection 9 Flexible Coupler Connection The flexible coupler is easy to use, and services do not have to be interrupted. The operating range is shorter than for direct connection methods. The tracing signal can be affected by neighboring cables and pipes. Neither the red/black test cord nor the ground rod are needed for this method. Loop the flexible coupler around the cable and connect the two ends. It is important to connect the flexible coupler around the cable you want to trace, as shown in Figure 6. Connecting it around a commonly bonded cable (dashed line in the figure) will cause the tracing signal to be weaker. The range will be shorter, and you may have trouble telling one cable from another. Plug the flexible coupler test cord into the DIRECT CONNECT jack. Set the 815Hz/OFF/82kHz switch to the 82 kHz position. The ON indicator will start blinking. Turn to Section 5, ?Locating the Cable or Pipe.? FLEXICOUPLER PATH FINDER II BURIED CABLE TEST CORD TRANSMITTER SET TO 82 KHZ Figure 6: Flexible Coupler Connection 10 Inductive Connection This method is convenient to use, and it is not necessary to interrupt services. No test leads are needed. When the cable or pipe has neither good insulation nor nonconductive coating, the operating range will be very short. BURIED CABLE 25 FEET 25 FEED PATHFINDER II TRANSMITTER SET TO 82 KHZ RECEIVER 90 SEARCH ZONE ARROWS 90 SEARCH ZONE RECEIVER Figure 7: Inductive Connection Place the transmitter on the ground, as close as possible to the path of the cable or pipe. Align the arrows on the transmitter control panel with the cable or pipe as shown in Figure 7. Set the 815Hz/OFF/82 kHz switch to the 82 kHz position. Th

    注意事项

    本文(Biddle L1050_UG 电路图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2026收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开