1、Instruction Manual AVTM651050 for L1050 Portable Locator Catalog No. 651050 High Voltage Equipment Aparato de Alto Voltaje Read the entire manual before operating. Antes de operar este producto lea este manual enteramente. AVO International 510 Township Line Road Blue Bell, PA 19422 U.S.A. (215) 646
2、-9200 RadioFans.CN 收音机爱 好者资料库 L1050 Portable Locator Instruction Manual Copyright March 1998 by AVO International All rights reserved. Reproduction without written permission is prohibited. Specifications are subject to change without notice. RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 ii TABLE
3、OF CONTENTS SectionPage 1Introduction.1 Receiving Instructions.1 General Information.1 2Safety.2 3Specifications.4 4Setup and Operation.5 Controls and Indicators.5 Select the Locating Method.6 Multiple Grounded Circuit.7 Flexible Coupler Connection.9 Inductive Connection.10 Direct Connection.11 Note
4、s on Selecting the Tracing Signal.12 Continuously Grounded Circuit.13 Telephone Direct Shield Connection.14 Telephone Direct Pair Connection .15 5Locating the Cable or Pipe.16 Procedure Using Peaking Antenna.16 Depth Measurements 70% Method .18 Depth Measurements Straight Lift Method.19 6Service.20
5、Maintenance.20 Repair.20 Warranty.21 LIST OF ILLUSTRATIONS Figure 1Transmitter Controls and Indicators.5 2Receiver Controls and Indicators.5 3Multiple Grounded CATV or Power Enclosure Connection.7 4Multiple Grounded Secondary Circuit Connection.8 5Multiple Grounded Telephone Pedestal Cover Connectio
6、n.8 6Flexible Coupler Connection.9 7Inductive Connection.10 8Direct Connection.11 9Continuously Grounded Circuit, Cable, Pipe, or Conduit.13 10Telephone Direct Shield Connection.14 11Telephone Direct Pair Connection .15 12Receiver Meter Readings .16 13Depth Measurement Using the 70% Method.18 14Dept
7、h Measurement Using the Straight Lift Method. 19 1 Section 1 Introduction Receiving Instructions Check the equipment received against the packing list to ensure that all materials are present. Notify AVO International of any shortage. Telephone (215) 646-9200 and ask for the customer service departm
8、ent. Examine the instrument for damage received in transit. If damage is discovered, file a claim with the carrier at once. Prepare a detailed description of the damage and notify AVO International. This instrument has been thoroughly tested and inspected to meet rigid specifications before being sh
9、ipped. It is ready for use when set up as indicated in this manual. General Information Thanks for purchasing the BIDDLE L1050 Portable Locator. The portable locator will help you detect and trace the routes of buried power cables, CATV cables, gas and water pipes, sewer lines, telephone cables, and
10、 fiber-optic cables. The transmitter applies a tracing signal onto a cable or pipe. The receiver detects the tracing signal and indicates how strong it is. You can locate the path of a buried pipe or cable by following the tracing signal. Supplied Components 1.Transmitter unit (built into carrying c
11、ase) 2.Receiver unit 3.Red/black test cord 4.Ground rod 5.Instruction Manual 6.Eight AA-size alkaline batteries 7.Eight D-size batteries Optional Flexible Coupler Preparation for Use Remove the receiver from the case, and turn it face-down. Locate the battery compartment on the back of the receiver.
12、 Install the eight AA-size batteries as marked on the case. 2 The transmitter battery compartment is situated under the receiver storage well, in the bottom of the case. Install the eight D-size transmitter batteries as marked on the case. Section 2 Safety The L1050 Portable Locator and the recommen
13、ded operating procedures have been designed with careful attention to safety; however, it is not possible to eliminate all hazards from electrical test equipment or to foresee every possible hazard that may occur. It is therefore essential that the user, in addition to following the safety rules in
14、this manual, also carefully consider all safety aspects of the test before proceeding. Safety is the responsibility of the user. Use suitable barriers, barricades, and warnings to keep people not actually engaged in the test at a safe distance. Make sure that no one can make contact with energized p
15、arts of the test equipment and the specimen under test. Treat all terminals of power equipment as a potential electric shock hazard. There is always the possibility of voltages being induced at these terminals because of proximity to energized high-voltage lines or equipment. Always turn the transmi
16、tter power off before touching any terminals. Always disconnect test leads from the cable under test before attempting to disconnect them from the portable locator. Never connect the test leads to a cable that does not have a safety ground strap in place. Never disconnect the test leads from a cable
17、 that does not have a safety ground strap in place. The safety ground connection must be the first made and the last removed. Any interruption of the grounding connection can create an electric shock hazard. Do not use this equipment to fault locate on any cable which is likely to be near enough to
18、an energized cable to allow a burn through of the insulation of the energized cable. This situation may occur when the cables are located in a common trench, duct or tray (for example, three- phase systems). Do not operate the equipment with protective covers removed. Operation without the protectiv
19、e covers presents an electric shock hazard. Use all practical safety precautions to prevent contact with energized parts of the equipment and related circuits. 3 Use the recommended grounding and connection procedures. Make sure that the equipment is grounded properly. Any interruption of the ground
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle L1050_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
TELEFUNKEN V101-1 电路原理图.jpg