JVC-MXKC45-cs-sm 维修电路原理图.pdf
《JVC-MXKC45-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-MXKC45-cs-sm 维修电路原理图.pdf(71页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5502006/7COMPACT COMPONENT SYSTEMMB55020067MX-KC45E,MX-KC45EN,MX-KC45A,MX-KC45UW,MX-KC45UY,MX-KC45UJLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53DISASSEMBLY . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-125TROUBLESHOO
4、TING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13CA-MXKC45SP-MXKC45SP-MXKC45RadioFans.CN 收音机爱 好者资料库1-2 (No.MB550)SPECIFICATIONDesign and specifications are subject to change without notice.AmplifierOutput Power
5、(IEC 268-3)155 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 10% total harmonic distortion(DIN-3)125 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 0.9% total harmonic distortionInput Sensitivity/Impedance (1 kHz)AUX INSpeaker terminals400 mV/50 k6 - 16 Phones3
6、2 - 1 k17 mW/ch output into 32 Cassette Deck Section Frequency Response : Type I (NORMAL) 63 Hz - 12 500 HzWow And Flutter0.15% (WRMS)CD PlayerCD Capacity3 CDsDynamic Range85 dBSignal-To-Noise Ratio85 dBWow And FlutterUnmeasurableTunerFM Tuner : Tuning Range87.50 MHz - 108.00 MHz87.50 MHz - 108.00 M
7、Hz (at AM9 kHz channel space)87.5 MHz - 108.0 MHz (at AM10 kHz channel space)AM Tuner : Tuning Range522 kHz - 1710 kHz522 kHz - 1 629 kHz (for Europe)531 kHz - 1710 kHz (at AM9 kHz channel space)530 kHz - 1710 kHz (at AM10 kHz channel space)UnitDimensions270 mm 307 mm 492 mm (W/H/D)MassApprox. 9.3 k
8、gSpeaker Specifications(each unit)Type3-way bass-reflex typeSpeaker UnitWoofer16 cm cone 1Mid5cm cone 1Tweeter2cm dome 1Power Handling Capacity160 WImpedance6 Frequency Range45 Hz - 22 000 HzSound pressure level87 dB/WmDimensions220 mm 324 mm 238 mm (W/H/D)MassApprox. 3.6 kgPower SpecificationsPower
9、 RequirementsAC 240 V , 50 Hz (for Australia)AC 230 V , 50 Hz (for Europe)AC 110 V-127 V/220 V-240 V , adjustable with voltage selector, 50 Hz/60 Hz (for Asia)Power Consumption165 W (power on mode)23 W (in Standby mode)1 W (in ECO mode)RadioFans.CN 收音机爱 好者资料库(No.MB550)1-3SECTION 1PRECAUTION1.1Safety
10、 Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose
11、 used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and
12、will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotecti
13、on afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shad
14、ing on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the
15、products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed
16、, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack,
17、control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of th
18、e cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensiti
19、vityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any expo
20、sed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been de
21、signed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replac
22、edby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn reg
23、ard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesa
24、me type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB550)1.5Important for laser products1.CLASS 1 L
25、ASER PRODUCT 2.CAUTION : (For U.S.A.) Visible and/or invisible class II laser radiation when open. Do not stare into beam. (Others) Visible and/or invisible class 1M laser radiation when open. Do not view directly with optical instruments. 3.CAUTION : Visible and/or invisible laser radiation when op
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-MXKC45-cs-sm 维修电路原理图 JVC MXKC45 cs sm 维修 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf