1、 Instruments Oscilloscope HM 305 ENGLISH 4S-0305-00E0 01 SEP 1996 SERVICE-MANUALHM305 RadioFans.CN 收音机爱 好者资料库 nderungen vorbehalten / Subject to change without notice 1 Y- Input, Attenuator, Preamplifier CH1. 2 Y- Input, Attenuator, Preamplifier CHII. 3 Y- Intermediate Amplifier CHI + CHII, Channel
2、Switch + Chopper Generator, . 4 Analog/ digital Switch, TRIG. and X- Signal Amplifier. 4 Trigger Amplifier, Trigger Coupling, TV Sync. Separator,. 5 Peak Value Detection, Trigger Comparator . 5 Timebase Sweep 8.3 YPA Board (Bottomside) nderungen vorbehalten / Subject to change without notice 20 Powe
3、r Supply Board (Topside) nderungen vorbehalten / Subject to change without notice 21 P1002 P1003 P1004 LINE BLV FOCUS G1 -1950V HT1 HT14 P1005 P1006 LINE +5V P1007 P1008 P1009 GND +12V -12V +5V +5V GND +12V -12V BLV HT1 HT14 -2025V HVC +185V +141V GND +12V -12V GND GND +12V -12V 4. R1003 3. R1004 1.
4、 R1008 2. R1016 INT. max.CUT-Off LEVEL 4.1 INTENS. on max. 4.2 adjust for max. intensity 3.1 INTENS. on min. 3.2 adjust for dark screen +12V10mV at 0,95A load current +141V0,2V at 60mA load current Adjustment Plan : Power Supply Board nderungen vorbehalten / Subject to change without notice 22 Digit
5、al Board (Topside) nderungen vorbehalten / Subject to change without notice 23 Adjustment Plan: Digital Board nderungen vorbehalten / Subject to change without notice 24 Front Controlboard (Topside, Bottomside) nderungen vorbehalten / Subject to change without notice 25 CRT Board (Topside, Bottomsid
6、e) nderungen vorbehalten / Subject to change without notice 26 XY Board (Topside) nderungen vorbehalten / Subject to change without notice 27 XY Board (Bottomside) nderungen vorbehalten / Subject to change without notice 28 TB Board (Topside) nderungen vorbehalten / Subject to change without notice
7、29 TB Board (Bottomside) nderungen vorbehalten / Subject to change without notice 30 CCT Board (Topside, Bottomside) nderungen vorbehalten / Subject to change without notice 31 Adjustment Procedure nderungen vorbehalten / Subject to change without notice 32 ADJUSTMENT PROCEDURE Digital Storage Scope
8、 HM305 WARNING The Instrument must be disconnected from the mains power supply whenever you open the case, repair or exchange parts. HIGH VOLTAGE WARNING! Hazardous High Voltage of up to 2,000 Volts is present inside this Instrument. The areas particularly affected by High Voltage are the high volta
9、ge circuit on the PS-board, the CRT-board and the CRT- socket. SERVICE AND ADJUSTMENT of this instrument should only be performed in accordance and in conjunction with the operating manual and the WARNINGS contained therein. should only be performed by suitable qualified and experienced service pers
10、onnel, or should be referred to one of the HAMEG companies listed on the rear cover of the manual. Test Instruments required: 1)Scope Tester HZ60-2. 2)Constant amplitude sinewave generator, 20Hz - 250MHz, output 5mV - 5V into 50, preferably with 20dB attenuation (e.g. HM8133, TEK SG502 + TEK SG503).
11、 3)Amplitude Calibrator with 1kHz squarewave output and 600 impedance, risetime faster than 150ns.Output voltage 2mV - 20Volts in 1-2-5 sequence for 4 divisions display amplitude (e.g. HZ62, TEK PG506). 4)Time mark generator from 5ns/div to 5s/div. Output min. 10mV into 50 (e.g. HZ62, TEK TG501). 5)
12、Pre-attenuator 2:1 (1M , 12-48pF), e.g. HZ20. 6)50 BNC through termination, e.g. HZ22. 7)2 BNC-cables, 50, e.g. HZ34. 8)BNC-T-connector. 9)Oscilloscope probe 10:1, with exactly 9M series resistance and compensated for test oscilloscope mentioned under 10). 10) Oscilloscope 100MHz, 5mV/div to 5V/div,
13、 e.g. HM1005. 11) Trimming/adjusting tool. 12) Variable output safety insulation transformer. 13) Video signal generator with positive and negative signal output. 14) Yt-EPROM HM1007. This procedure covers all adjustments and the most important - but not all - performance checks. The correct sequenc
14、e of all adjustment steps must be strictly followed. Exact adjustment is only possible when any influence of the earths magnetic field has been compensated with the trimmer marked TR (trace rotation). All adjustments should only be performed by qualified and experienced personnel. This is particular
15、ly important for adjustments in the high voltage section of the instrument. nderungen vorbehalten / Subject to change without notice 33 1) R1008: +141 Volt supply. 35 2) R1016: +12 Volt supply. 35 3) RV7000: Trace Rotation Check. . 35 4) R1004 : CRT minimum intensity. . 35 5) R1003 : CRT maximum int
16、ensity. . 35 6) R712: Mean Y-plate Potential Channel I. . 35 7) R714: Mean Y-plate Potential Channel II. . 37 8) RV6021 : Astigmatism correction. 37 9) R640: Y-Gain CH I. . 37 10) R122: FET operating point CH I. . 37 11) R203: Invert-Balance CH I. . 37 12) R177: Variable-Balance CH I. . 37 13) R139:
17、 100Hz Squarewave 5mV/div CH I. . 38 14) R134: 100Hz Squarewave 1mV/div Adjustment CH I. . 39 15) R658: Y-Gain CH II. . 39 16) R422: FET operating point CH II. . 39 17) R503: Invert-Balance CH II. . 39 18) R477: Variable-Balance CH I. . 39 19) R439: 100Hz Squarewave 5mV/div CH II. . 39 20) R434: 100
18、Hz Squarewave 1mV/div CH II. . 39 21) RV2005 (A), RV2006 (C), CV2000 (D) and CV2001 (B): . 41 22) Y-Amplifier Bandwidth Check. . 41 23) C111 (A)/113 (B)/102 (C)/105 (D):Attenuator Compensation CH I. . 41 24) C411 (A)/413 (B)/402 (C)/405 (D): Attenuator Compensation CH II. . 41 25) RV2501 (A): Storag