D26 Owner's Manual Rev2 电路图.pdf
《D26 Owner's Manual Rev2 电路图.pdf》由会员分享,可在线阅读,更多相关《D26 Owner's Manual Rev2 电路图.pdf(13页珍藏版)》请在收音机爱好者资料库上搜索。
1、 S O U N D S C I E N C E Model D26 Digital System Controller Owners Manual Rev. 2 RadioFans.CN 收音机爱 好者资料库 This equipment has been tested and found to comply with the following European and international Standards for Electromagnetic Compatibility and Electrical Safety: Radiated Emissions (EU): EN550
2、13 (1990) Associated Equipment RF Immunity (EU): EN50082/1 (1992) RF Immunity, Fast Transients ESD Mains Disturbance (EU): EN61000/3/2 (1995) Electrical Safety (EU): EN60065 (1993) Radiated Emissions (USA): FCC part 15 Class B Electrical Safety (USA): UL813/ETL (1996) Commercial Audio Equipment Elec
3、trical Safety (CAN): UL813/ETLc (1996) Commercial Audio Equipment IMPORTANT SAFETY INFORMATION DO NOT REMOVE COVERS. NO USER SERVICEABLE PARTS INSIDE, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. THIS EQUIPMENT MUST BE EARTHED. IT SHOULD NOT BE NECESSARY TO REMOVE ANY PROTECTIVE EARTH OR SIGNAL C
4、ABLE SHIELD CONNECTIONS TO PREVENT GROUND LOOPS. ANY SUCH DISCONNECTIONS ARE OUTSIDE THE RECOMMENDED PRACTISE OF CUSTOMER NAME AND WILL RENDER ANY EMC OR SAFETY CERTIFICATION VOID. For continued compliance with international EMC legislation ensure that all input and output cables are wired with the
5、cable screen connected to Pin 1 of the XLR connectors. The input XLR Pin 1 is connected to the chassis via a low value capacitor, providing high immunity from ground loops whilst ensuring good EMC performance. RadioFans.CN 收音机爱 好者资料库 Contents Quick Start - Reference Other features Voltage setting AC
6、 Power fusing Mechanical Installation Mains Power Connection Controls Input section Output section Rear panel Moving about the screens Default Screen Inputs Menu Outputs Menu EQ Screens Store and Recall System Security Specifications Quick Start - Reference AC Power connection The D26 has a universa
7、l voltage AC Power input. Connect the D26 to AC Power with the lead supplied. The unit will switch on automatically (there is no separate on/off switch). The display will show the default screen, with the current program (if selected), and overall system response curves. Audio connections Connect th
8、e inputs and outputs as desired. All inputs and outputs are electronically balanced, with Pin 2 hot signal (+ve). Do not put any audio through the unit at this time. Program settings If your D26 has been already configured with a program, you only need to use the RECALL mode to set the parameters to
9、 that program. Press RECALL. Use the Parameter UP/DOWN keys to select the designated program (which has a number and name) and press RECALL again. Programs marked with the letter M are Master OEM programs and have been designed to match specific sound systems. Some units will be locked to a specific
10、 program. In this case most controls will be disabled and the unit will be ready for use. Setting up a system To configure your D26, the mode of the unit should be decided upon before setting up. Once the Config is set (In the Utilities menu), the crossover points, individual band delays, any EQ, an
11、d limiter thresholds can be set up. To enter the Utilities menu, press the RIGHT key from the default screen. Configuring the D26 Band delays Use the RIGHT/LEFT keys until the delay screen appears. The delay is adjusted by the Parameter UP/DOWN keys. Default settings for display and adjustment of de
12、lay is in meters (m), but can be changed to milliseconds (ms), or feet/inches (ft). Bands can also be linked so multiple outputs can be delayed as one using the delay link facility. Adding EQ Use the RIGHT/LEFT keys to move to the EQ screen. The EQ shape can be edited first. The shape of the EQ can
13、be selected from one of the following by pushing the Parameter UP/DOWN keys: Hi-Shelf with 12dB slope (Hi12) Hi-Shelf with 6dB slope (Hi6) BELL Low-Shelf with 6dB slope (Lo6) Low-Shelf with 12dB slope (Lo12). Pushing the RIGHT key from the EQ shape screen will access the following facilities, in thi
14、s order: Filter Frequency Cut/Boost Filter Bandwidth Setting the limiters There is one screen associated with the limiters of the D26, which allows you to set the limiter threshold. Push the Parameter UP/DOWN keys to change the threshold. The output meters are calibrated to this threshold, so the th
15、reshold will show as Set the 0dB point on the meter at all times, even if the limiters are off. Other features Crossover slopes of 6,12, 18, 24 or 48dB per octave, filter types Butterworth or Linkwitz-Riley, preset at the factory as appropriate. Output limiters on each band (mid-filter). High resolu
16、tion input and output delays up to 630 seconds in 22 microsecond steps. Input LED metering, showing signals from -20dB to clip level. Output LED metering, showing signals from -20dB to +6dB over limit threshold. Front panel mutes. Polarity reverse on each output. Electronically balanced inputs and o
17、utputs. MIDI and RS-232 ports on rear panel. Voltage setting The D26 uses a switched-mode power supply which offers high efficiency and low heat generation. This power supply accepts universal AC Power input voltages in the range 100V AC to 240V AC (nominal), and requires no setting adjustment for A
18、C power voltages in this range. Minimum AC input voltage is 90 Volts, and the maximum is 264 volts. Outside these ranges the unit will not work satisfactorily, if at all. Voltages in excess of the maximum will probably cause damage. Voltages below the minimum will cause complete system shutdown. The
19、 flash memory in the unit will preserve all data in the event of a power failure. AC Power fusing The Green-and-Yellow wire of the mains cord must always be connected to an installation Safety Earth or Ground. The Earth is essential for personal safety as well as the correct operation of the system,
20、 and is internally connected to all exposed metal surfaces. Any rack framework into which this unit may be mounted is assumed to be connected to the same grounding circuit. The incoming mains power is fused within the D26 by the fuse holder mounted on the rear panel. Always replace with an identical
21、 20mm x 5mm T fuse, rated at 1A for continued protection from equipment damage and fire. It is most important for continued safety that this specification is strictly adhered to. Mechanical Installation A vertical rack space of 1U (1 / 44.5 mm high) is required. Ventilation gaps are unnecessary. If
22、the D26 is likely to undergo extreme vibration through extensive road trucking and touring, it is advisable to support the unit at the rear and/or sides to lessen the stress on the front mounting flange. The necessary support can generally be bought ready-built as a rack tray. As with any low-level
23、signal processing electronics, it is best to avoid mounting the unit next to a strong source of magnetic radiation, for example, a high power amplifier, to help keep residual noise levels in the system to a minimum. Mains Power Connection Mains power WARNING! THIS APPLIANCE MUST BE EARTHED. IMPORTAN
24、T: The wires in the mains lead are colour coded in accordance with the following code. ? The wire which is coloured Green and Yellow or Green must be connected to the terminal which is marked with the letter E or by the Earth signal or which is coloured Green and Yellow or Green. ? The wire which is
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- D26 Owner's Manual Rev2 电路图 Owner
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
EMUD L2Wund200W电路原理图.jpg