NAD-T531-cd-sm2 电路图 维修手册.pdf
《NAD-T531-cd-sm2 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《NAD-T531-cd-sm2 电路图 维修手册.pdf(91页珍藏版)》请在收音机爱好者资料库上搜索。
1、CONTENTS SECTION 1 . . . .SUMMARY SECTION 2 . . . .CABINET & MAIN CHASSIS SECTION 3 . . . .ELECTRICAL SECTION 4 . . . .MECHANISM SECTION 5 . . . .REPLACEMENT PARTS LIST RadioFans.CN 收音机爱 好者资料库 SECTION 1 SUMMARY CONTENTS PRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS. 1-3 SERVICING PRECAUTION
2、S. 1-4 General Servicing Precautions Insulation Checking Prodedure Electrostatically Sensitive Devices SPECIFICATIONS. 1-5 RadioFans.CN 收音机爱 好者资料库 1-3 Prior to shipment from the factory, the products are strictly inspected to conform with the recognized product safety and electrical codes of the cou
3、ntries in which they are to be sold. However, in order to maintain such com- pliance, it is equally important to implement the following precautions when a set is being serviced. Precautions during Servicing 1. Locations requiring special caution are denoted by labels and inscriptions on the cabinet
4、, chassis and certain parts of the product. When performing service, be sure to read and comply with these and other cautionary notices appearing in the operation and service manuals. 2. Parts identified by the symbol and shaded ( Y) parts are critical for safety. Replace only with specified part nu
5、mbers. Note : Parts in this category also include those specified to comply with X-ray emission standards for products using cathode ray tubes and those specified for compliance with various regulations regarding spurious radiation emission. 3. Use Specified internal wiring. Note especially: 1) Doub
6、le insulated wires 2) High voltage leads 4. Use specified insulating materials for hazardous live parts. Note especially: 1) Insulation Tape 2) PVC tubing 3) Spacers 4) Insulation sheets for transistor 5. Observe that wires do not contact heat producing parts (heatsinks, oxide metal film resistors,
7、fusible resistors, etc.) 6. Check that replaced wires do not contact sharp edged or pointed parts. 7. 1) When a power cord has been replaced, check that A mark is made on the cord, under strain, near the aperture, and the flexible cord is subjected 100 times to a pull of 40N for a duration of 1 seco
8、nd each. 2) During the test, the cord shall not be displaced by more than 2mm 8. Also check areas surrounding repaired locations. IMPORTANT SAFETY PRECAUTIONS Fig. 1 Power cord RadioFans.CN 收音机爱 好者资料库 1-4 Fig. 3 SAFETY CHECK AFTER SERVICING Examine the area surrounding the repaired location for dama
9、ge or deterioration. Observe that screws, parts and wires have been returned to original positions. Afterwards, perform the following tests and confirm the specified values in order to verify compliance with safety standards. Insulation resistance test confirm the specified insulation resistance or
10、greater between power cord plug prongs and externally exposed parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.) See table below. Dielectric strength test Confirm specified dielectric strength or greater between powe
11、r cord prongs and exposed accessible parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.) See table below. Clearance distance When replacing primary circuit components, confirm specified clearance distance (d), (d) bet
12、ween sol- dered terminals, and between terminals and sur- rounding metallic parts. See table below. Table 1 : Ratings for selected areas * Class II model only. Note. This table is unofficial and for reference only. Be sure to confirm the precise values for your particular country and locality. Leaka
13、ge Current test Confirm specified or lower leakage current between B(earth ground, power cord plug prongs) and externally exposed accessible parts (RF terminals, antenna terminals, video and audio input and output terminals, micro- phone jacks, earphone jacks, etc.) Measuring Method: (Power ON) Inse
14、rt load Z between B(earth ground, power cord plug prongs) and exposed accessible parts. Use an AC voltmeter to measure across both terminals of load Z. See figure and following table. Table 2:Leakage current ratings for selected areas. Note. This table is for IEC member only. Be sure to confirm the
15、precise values for your particular country and Note. locality. Chassis d a Primary circuit terminals Exposed accessible part Z Load AC Voltmeter Earth Ground, Power cord plug prongs B Fig. 2 AC Line Voltage AC Line Voltage 100 to 130 V 200 to 240 V *100 to 130 V *200 to 240 V Australia Europe Austra
16、lia Europe Other terminals Antenna earth terminals i E 0.7m A peak i E 2m A DC i E 0.7m A peak i E 2m A DC F 10 M/500 V DC4kV 1 minute F 6mm(d) F 8mm(d) (a Power cord) RegionLoad ZLeakage Current(i) Earth Ground (B) to : Region Insulation Resistance Dielectric Strength Clearance Distance(d),(d) 2k 5
17、0k 1-5 SPECIFICATIONS DVD VIDEO PLAYER Power supplyAC 110240V, 50/60Hz(T531B, T531C) AC 120V, 60Hz(T531AH) Power consumtion16W Mass3.0kg(6.6lbs) External dimensions435 x 88 x 247 mm (W x H x D) Signal systemPAL 625/50, NTSC 525/60 LaserSemiconductor laser, wavelength 650nm Frequency range (digital a
18、udio)4Hz to 20kHz Signal-to-noise ratio (digital audio)More than 100dB (EIAJ) Audio dynamic range (digital audio)More than 95dB (EIAJ) Harmonic distortion(digital audio)0.008% Wow and flutterBelow measurable level (less than +0.001%(W.PEAK) (EIAJ) OperationsTemperature : 5C(41F) to 35C(95F), Operati