1、SERVICE MANUAL COPYRIGHT 2005 VICTOR COMPANY OF JAPAN, LIMITED No.YD085 2005/11 Mini DV with Viterbi OFF. Inter-channel difference: 10 times be- tween CH1 and CH2. Note 6 : It is desirable to use a brand-new tape or an unused section of tape. This is to assure the adjustment reliability because usin
2、g a damaged tape increases the error rate. 4.10.6 Error rate measuring method It is not necessary to use the error rate jig (YTU93083) or a fre- quency counter. The Service Support System Software displays the error rates of video CH1, CH2 and totals. When measuring the error rate of a channel, be s
3、ure to total the values of the video and the audio errors. Play the alignment tape, then set “ATF” (Auto Tracking Find) in “Deck Controller” of the SSS Software to ON. (Note 3) Connect an oscilloscope (CH: + Slope) and, while triggering it with the HID signal, observe the ENV OUT The linearity adjus
4、tment is complete if the PB ENV waveform is ideally stable and varies ideally according to the tracking variation. To close, play a prerecorded tape and check the audio and video. Is the PB ENV waveform ideally stable and does it vary ideally according to the tracking variation? Yes No Ensure that t
5、he ENV OUT waveform is linear and parallel, without a noticeable drop or variation in the overall level. If the waveform linearity is poor or there is a noticeable drop in level, adjust the guide roller by turning it with the roller driver. Set “ATF” (Auto Tracking Find) to OFF using “Deck Controlle
6、r” of the SSS Software (Note 4). Observe the ENV OUT waveform to confirm that the overall waveform balance and linearity levels vary in accordance with the tracking variation as shown in Fig. 4-10-4. Repeat above steps as required. PB ENV waveform Adjust variation in the parallelism HID waveform CH1
7、 CH2 The “PB Switching Point” in the Adjustment Utility of the SSS software is adjusted automatically. Load the alignment tape. While playing the recorded signal, adjust “VCO Center Frequency (ME SP)” or “VCO Center Frequency (ME LP)” in “Deck Section” of the Adjustment Utility. To adjust VCO Center
8、 Frequency (ME SP) : Set Viterbi OFF. To adjust VCO Center Frequency (ME LP) : Set Viterbi ON. Record for about 5 minutes. (Note 6) The error rate adjustment is complete when the minimum error rate which is no higher than the typical value is obtained. (Note 5) Is the obtained error rate minimum (al
9、most the typical value)? Yes No 1-32 (No.YD085) 4.11 Electrical adjustment (DV SECTION) 4.11.1 Precautions (1) The DV section of this model is based on a special adjust- ment method using a PC. However, ordinary adjustment is required only when the part listed below has been re- placed. In this case
10、, the adjustment should be performed by a service center equipped with the required facilities. E2 PROM (IC1504 on DV main board) In case of trouble with the electrical circuitry, First identify the faulty position with a measuring tool as described be- low. Proceed to repair, replacement and/or adj
11、ustment only after the troubleshooting. (2) When observing a chip TP, use an IC clip or similar tool to protect the chip against stress. When replacing a chip part (IC, particularly), remove solder completely before replac- ing. (This is to prevent separation of the pattern.) (3) The connectors are
12、fragile. Be careful when plugging or un- plugging a wire. 4.11.2 Equipment required for adjustment Personal computer (Windows compatible) Color monitor Oscilloscope (2-CH, 100 MHz or more) Frequency counter 4.11.3 Tools required for adjustments Fig.4-11-1 4.11.4 Setup 1. Setup for computer adjustmen
13、t - Setup by extending the jig connector - Fig.4-11-2 Alignment tape US : MC-1 PAL : MC-2 SSS software PTU94016-5 Guide driver YTU94085 Jig connector cable PTU94018B PC cable US : QAM0099-002 PAL : QAM0099-005 Jig RCU PTU94023B DV MAIN PWB CN2001 CN1501 CN1503 CN3701 Service Support Software RS-232C
14、 Port PC Cable Personal Computer JVC MENU -Setup by extending the jig connector- Connect the Jig Connector Cable and setup the SSS software. It automatically becomes the TCCS mode and TCCS is displayed on the FDP. To cancel the TCCS mode, press the CANCEL button of the remote control unit. The TCCS
15、display on the FDP disappears. (No.YD085)1-33 4.12 Electrical adjustment (DVD SECTION) Note: The following adjustment procedures are not only necessary after replacement of consumable mechanical parts or board assemblies, but are also provided as references to be referred to when servicing the elect
16、rical circuitry. In case of trouble with the electrical circuitry, always begin a service by identifying the defective points by using the measur- ing instruments as described in the following electrical adjust- ment procedures. After this, proceed to the repair, replacement and/or adjustment. If th
17、e required measuring in- struments are not available in the field, do not change the ad- justment parts (variable resistor, etc.) carelessly. 4.12.1 DVD Video circuit Note When perform these adjustments, set the unit to DVD mode.(DVD lamp lights up) 4.12.1.1 EE Composite Y level (1) Observe the V OU
18、T waveform at the measuring point (D). (2) Set the VCR to the EVR mode by transmitting the code (F1) from the Jig RCU. (3) Set the EVR address to (F2) by transmitting the code (F3) from the Jig RCU. (4) Transmit the code (F4) from the Jig RCU to adjust so that the Y level of the V OUT waveform becom
19、es the specified value (G). (5) Release the EVR mode of the VCR by transmitting the code (F5) from the Jig RCU again. (When the EVR mode is released, the adjusted data is memorized.) Fig.4-12-1 EE composite Y level 4.12.1.2 EE Y level (1) Observe the V OUT waveform at the measuring point (D). (2) Se
20、t the VCR to the EVR mode by transmitting the code (F1) from the Jig RCU. (3) Set the EVR address to (F2) by transmitting the code (F3) from the Jig RCU. (4) Transmit the code (F4) from the Jig RCU to adjust so that the Y level of the V OUT waveform becomes the specified value (G). (5) Release the E
21、VR mode of the VCR by transmitting the code (F5) from the Jig RCU again. (When the EVR mode is released, the adjusted data is memorized.) Fig.4-12-2 EE Y level 4.12.1.3 EE composite burst level (1) Observe the V OUT waveform at the measuring point (D). (2) Set the VCR to the EVR mode by transmitting
22、 the code (F1) from the Jig RCU. (3) Set the EVR address to (F2) by transmitting the code (F3) from the Jig RCU. (4) Transmit the code (F4) from the Jig RCU to adjust so that the burst level of the V OUT waveform becomes the spec- ified value (G). (5) Release the EVR mode of the VCR by transmitting
23、the code (F5) from the Jig RCU again. (When the EVR mode is released, the adjusted data is memorized.) Signal(A) Internal colour bar Mode(B) EE Equipment(C) Oscilloscope Measuring point (D) L-1 connector pin19 EVR mode EVR address (F1) (F2) (F3) (F4) (F5) Jig code “43-95” ADJUST01 : * Jig code “43-2
24、1” Jig code “43-18” or “43-19” (Channel +/-) Jig code “43-3C” Specified value(G) 1.00 0.02 Vp-p (terminated) Adjustment tool (H) Jig RCU PTU94023B Specified value (G) H. rate Signal(A1) (A2) Ext. input Color (colour) bar signal Mode(B) EE Equipment(C) Oscilloscope Measuring point (D) L-1 connector p