Bogen-AFDS2-Operation-Manual 电路图 维修手册.pdf
《Bogen-AFDS2-Operation-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bogen-AFDS2-Operation-Manual 电路图 维修手册.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、Automatic Failure Detector and Substitutor AFDS2 Model Installation and Use Manual 2005 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5693-10B 0507 RadioFans.CN 收音机爱 好者资料库 DESCRIPTION The Bogen Model AFDS2,Automatic Failure Detector and Substitut
2、or,is an electronic unit which continuously supervises the operation of the main and standby power amplifiers in a sound system. Should the main amplifiers output level drop by as little as 2 dB,the AFDS2 substitutes the standby power amplifier.The changeover is nearly instantaneous with virtually n
3、o loss of signal. The AFDS2 injects a set level of a supersonic frequency (40 kHz) into the inputs of the main and standby power amplifiers and continuously samples their outputs. If the 40 kHz level from either amplifier should fall below 2 dB*, a fault alert tone will sound,indicating a failure.Fr
4、ont panel-mounted LEDs indicate whether the main amplifier or the standby amplifier failed. The fault alert tone may be silenced by momentarily pressing the Silence button;however,the LED will stay on for the dura- tion of the malfunction. The AFDS2 may be used in either 25V or 70V systems.Booster o
5、utput may be balanced or unbalanced;but,in a balanced sys- tem, two accessory input isolation transformers (Model TL100) are required. The AFDS2 input impedance from the audio source is 10,000 ohms. In applications where the pre-amplifier is located away from the amplifier, the AFDS2 input can be co
6、nverted to 600 ohms with the accessory WMT1A Line-Matching Transformer. Screwdriver-adjustable controls for setting the oscillator level and the detector sensitivities are provided on the rear panel. The AFDS2 operates from a 120V AC/60 Hz or 12V DC source.Line power consumption is 15W.All connectio
7、ns are made at screw terminals and RCA connectors on the rear chassis.The unit has a standard 19-inch wide panel, is 3 1/2-inches high and is suitable for either rack or cabinet installation. * Threshold is adjustable PACKAGE CONTENTS Automatic Failure Detector WMT1A Line-Matching Transformer to mat
8、ch the input from a 600-ohm balanced line EQUIPMENT CONNECTIONS AC Power Connections:The AC line cord has a three-prong plug which should be plugged into a three-wire grounded 120V, 60 Hz outlet.This will automatically ground the chassis. Auxiliary DC Power Connections: The unit may be powered from
9、the 12V DC supply.The positive lead must be con- nected to the EXT PWR terminal on the chassis and the negative lead to the GND terminal. Input Connections:The input impedance of the AFDS2 is 10,000 ohms, accepting any unbalanced input capable of supply- ing a signal at least 10% greater than that n
10、eeded to drive the power amplifiers (which must have an input impedance of 10,000 ohms or greater). Provisions are incorporated for mounting an accessory Model WMT1A transformer to match the input from a 600-ohm balanced line. System Connections: Single-conductor, low capacity shielded wire should b
11、e used for all input connections.These leads should be as short as possible. The remaining connections can be made with either double-conductor shielded wire or #20AWG hookup wire. Note: Input cables should be routed separately from output cables. RadioFans.CN 收音机爱 好者资料库 Balanced System Applications
12、: In a balanced 25V or 70V constant voltage system, two accessory input isolation trans- formers (Model TL100) are required.To install the transformers, remove the cover, plug the transformers into the nine-pin sockets T1 and T2 on the PC board and cut the jumpers between terminals 9 and 10 and betw
13、een terminals 22 and 23. Status Terminal Connection: Remote identification of failure of the main amplifier and/or standby amplifier can be obtained by connecting a pair of wires and an annunciator to the Status Terminal.12V DC 500mA (maximum) are provid- ed in the failure mode. SETUP PROCEDURES MAI
14、N AMPLIFIER 1.Connect an ACDVM across the output terminals of the main amplifier on the constant voltage setting being used (25V or 70V). Note: Make certain that the AFDS2 is installed with all speaker loads by connecting the amplifier rated load across the Speaker Line (Hi and Lo) terminals.Turn th
15、e Main Amp Detector Sensitivity control,R33,and the Standby Amp Detector Sensitivity control,R2,fully clockwise. If the DVM reads zero, rotate the 40 kHz Oscillator Level control, R21, clockwise until the Speaker Line switches to the main power amplifier. 2. Set the audio source and main amplifier v
16、olume controls to their normal settings for maximum level of required program material. Record the settings. Use a tone generator, tuner, tape or phono input as the program input source. 3.Disconnect the audio source input to the AFDS2 and set the Oscillator Level control,R21,so that the DVM reads a