1、Specifications subject to change without notice. 2009 Bogen Communications, Inc. All rights reserved. 54-5810-05C 1206 BPA60 Power Ampl ifier I nstal l ation l ow- impedance bal anced ( with optional transformer) , 75mV Hum and Noise:85 dB bel ow rated output Out put Loads:8- ohm/ 25V, 16- ohm, 25V
2、CT, 70V Out put Regul at ion:Better than 2 dB from no l oad to ful l l oad I nput I mpedances:High- impedance, 50k ohms unbal anced; l ow- impedance, 600 ohms, bal anced ( with optional transformer) Lo- cut Fil t er:- 10 dB at 100 Hz ( switch- sel ectabl e) Cont rol s and I ndicat ors:Fr ont Panel I
3、 l l uminated on/ off power switch Rear Panel I nput l evel control , circuit breaker reset, l o- cut fil ter switch Power Consumpt ion:120V AC, 60 Hz, 180W at ful l rated output Thermal Emissions (ful l power):204. 9 BTU/ hr. Overl oad Prot ect ion:Transient protection diodes, el ectrical circuit b
4、reaker, thermostat Operat ing Temperat ure Range:- 4 F to 131 F ( - 20 to +55 C) at rated output Auxil iary Recept acl e (not swit ched): Three- wire grounded* , 300W maximum, 2. 5A ( internal l y fused) Dimensions:15- 1/ 4W x 3- 1/ 2H x 8- 1/ 4D Finish:Bl ack Product Weight :17 l bs. Approval s:Lis
5、ted to UL Standard 60065 for US and Canada Accessories:Model TL600, 600- ohm l ine- matching transformer; Model TL100, 1: 1 ratio transformer; Model RPK53 rack panel brackets *This r eceptacle will be gr ounded only if the power amplifier has been gr ounded pr oper ly. Technical Specificat ions Radi
6、oFans.CN 收音机爱 好者资料库 NOTI CE:Every effort was made to ensure that the information in this guide was compl ete and accurate at the time of printing. However, information is subject to change. WARNI NG: To reduce the risk of Fire or El ectric Shock, Do Not Expose this apparatus to rain or moisture. App
7、aratus shal l not be exposed to dripping or spl ashing and no objects fil l ed with l iquids, such as vases shal l be pl aced on the apparatus. WARNI NG: Onl y connect unit to AC mains outl et providing protective earthing connection. NOTE:Mains pl ug is used as disconnect device from the mains and
8、shal l remain readil y accessibl e and operabl e. CAUTI ON: These servicing instructions are for use by qual ified service per- sonnel onl y. To reduce the risk of el ectric shock, do not perform any servicing other than that contained in the operating instructions unl ess you are qual ified to do s
9、o. CAUTI ON: DO NOT I NSTALL OR PLACE THI S UNI T I N A BOOKCASE, BUI LT- I N CABI NET , OR I N ANOTHER CONFI NED SPACE. ENSURE THE UNI T I S WELL VENTI LATED. TO PREVENT THE RI SK OF SHOCK OR FI RE HAZARD DUE TO OVER- HEATI NG, ENSURE THAT CURTAI NS AND ANY OTHER MATERI ALS DO NOT OBSTRUCT THE VENT
10、I LATI ON VENTS. Al ways fol l ow t hese basic safet y precaut ions when inst al l ing and using t he unit : I MPORTANT SAFETY I NSTRUCTI ONS 1. Read these instructions. 2. Keep these instructions. 3. Heed al l warnings. 4. Fol l ow al l instructions. 5. Do not use this apparatus near water. 6. Cl e
11、an unit with dry cl oth. 7. Do not bl ock any ventil ation openings. I nstal l in accordance with the manufacturer s instructions. 8. Do not instal l near any heat sources such as radiators, heat registers, stoves, or other apparatus ( incl uding ampl ifiers) that produce heat. 9. Do not defeat the
12、safety purpose of the pol arized or grounding- type pl ug. A pol arized pl ug has two bl ades with one wider than the other. A grounding- type pl ug has two bl ades and a third grounding prong. The wide bl ade, or the third prong, are provided for your safety. I f the provided pl ug does not fit int
13、o your outl et, consul t an el ectrician for repl acement of the obsol ete outl et. 10. Protect the power cord from being wal ked on or pinched particul arl y at pl ugs, convenience receptacl es, and the point where they exit from the apparatus. 11. Onl y use attachments/ accessories specified by th
14、e manufacturer. 12. Unpl ug this apparatus during l ightning storms or when not used for l ong periods of time. 13. Refer al l servicing to qual ified service personnel . Servicing is required when the apparatus has been damaged in any way, such as power- suppl y cord or pl ug is damaged, l iquid ha
15、s been spil l ed or objects have fal l en into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normal l y, or has been dropped. CAUTI ON RI SK OF ELECTRI C SHOCK DO NOT OPEN CAUTI ON: TO PREVENT THE RI SK OF ELECTRI C SHOCK, DO NOT REMOVE ANY FRONT/ BACK COVERS OR
16、 PANELS. NO USER- SERVI CEABLE PARTS I NSI DE. REFER SERVI CI NG TO QUALI FI ED PERSONNEL. The excl amation point within an equi- l ateral triangl e is intended to al ert the user to the presence of important operating and maintenance ( servicing) instructions. The l ightning fl ash with arrowhead s
17、ym- bol , within an equil ateral triangl e, is in- tended to al ert the user to the presence of uninsul ated dangerous vol tage within the product s encl osure that may be of sufficient magnitude to constitute a risk of el ectric shock to persons. RadioFans.CN 收音机爱 好者资料库 I nst al l at ion Rack Mount
18、 ed I nst al l at ion The ampl ifier may be mounted in a standard 19” equipment rack, by using the Bogen Model RPK53 Rack Panel Kit ( accessory; sol d separatel y) , which incl udes two brackets and the necessary hardware for instal l ation. NOTE: Befor e installing the amplifier in a r ack, install
19、 any accessor y tr ansfor mer s r equir ed. See Input Connections section. Attach one of the RPK53 brackets to each side of the unit and se- cure ( with screws provided) through the hol es on the side panel . Each bracket measures 2”W x 3- 1/ 2”H x 1”D. Vent il at ion The ampl ifier generates heat d
20、uring operation. I t must be prop- erl y ventil ated to prevent excessive temperature rise. I f other heat- producing equipment, or several ampl ifiers have been instal l ed in an encl osed rack or cabinet, you must ensure that there is space above and bel ow the ampl ifier( s) to al l ow for passiv
21、e cool ing. I t is recommended that the ampl ifier be instal l ed on the bottom of a rack or above any equipment that does not produce heat. Power and Grounding The three- wire AC l ine cord has a three- prong pl ug which shoul d be pl ugged into a properl y grounded, three- wire, 120V 60Hz outl et.
22、 I t is important to ground the ampl ifier. Auxil iary Power Recept acl e Caution:The fr ont panel POWER switch does not contr ol the aux- iliar y r eceptacle. The AUX POWER receptacl e on the rear panel is a three- wire grounded outl et that may be used to suppl y power to accessory equipment in th
23、e sound system. Ensure that the accessory equip- ment does not require more than 300 watts. Equipment connected to the auxil iary receptacl e wil l be grounded, provided the ampl ifier l ine cord has been properl y grounded. The outl et is protected by an internal fuse. I nput Connect ions High- I m
24、pedance I nput A high- impedance input is provided by standard RCA jacks (see Fig. 1) . An input signal of 300mV is required for ful l rated output. Low- I mpedance Bal anced I nput Caution: To avoid electr ic shock, be sur e to disconnect AC Power Cor d befor e r emoving the cover of the amplifier
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Bogen-BPA-60-Operation-Manual 电路图 维修手册 Bogen BPA 60 Operation Manual 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf