Grundig-UMS-3000-Service-Manual电路原理图.pdf
《Grundig-UMS-3000-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Grundig-UMS-3000-Service-Manual电路原理图.pdf(31页珍藏版)》请在收音机爱好者资料库上搜索。
1、UMS 3000GLR1100Zustzlich erforderliche Unterlagen fr den KomplettserviceAdditionally required Service Documents for the Complete ServiceServiceManualSicherheitSafetyMaterialnr./Part No.720108000001HiFi Service ManualMaterialnummer/Part Number 720107736000nderungen vorbehalten/Subject to alterationH-
2、S43 0405 Printed in Germanyhttp:/GRUNDIG Service UMS 30001 - 2Es gelten die Vorschriften und Sicherheitshin-weise gem dem Service Manual “Sicherheit“,Materialnummer 720108000001, sowie zustz-lich die eventuell abweichenden, landes-spezifischen Vorschriften!The regulations and safety instructions sha
3、ll bevalid as provided by the “Safety“ Service Manual,part number 720108000001, as well as the re-spective national deviations!Table of ContentsPageGeneral Section . 1-2 1-10Measuring Instruments / Equipment . 1-2General Notes . 1-2Technical Data . 1-3Service Hints . 1-3Operating Hints . 1-7Disassem
4、bly Hints . 1-10Adjustment Procedures. 2-2Layout of PCBsand Circuit Diagrams . 3-1 3-16Block Diagram . 3-1Wiring Diagram . 3-2Power Supply and Audio Section . 3-3CD Section . 3-6MCU and Display Section . 3-8Radio Section . 3-12Tape Section . 3-15Exploded View andSpare Parts List . 4-1 4-3Exploded Vi
5、ew . 4-1Spare Parts List . 4-2InhaltsverzeichnisSeiteAllgemeiner Teil . 1-2 1-10Messgerte / Messmittel . 1-2Allgemeine Hinweise . 1-2Technische Daten . 1-3Servicehinweise . 1-3Bedienhinweise . 1-4Ausbauhinweise . 1-10Abgleichvorschriften . 2-1Platinenabbildungenund Schaltplne . 3-1 3-16Blockschaltpl
6、an . 3-1Verdrahtungsplan . 3-2Netzteil und Audio-Teil . 3-3CD-Teil . 3-6MCU- und Display-Teil . 3-8Radio-Teil . 3-12Cassetten-Teil . 3-15Explosionszeichnung undErsatzteilliste . 4-1 4-3Explosionszeichnung . 4-1Ersatzteilliste . 4-2General SectionMeasuring Instruments / EquipmentSignal generator Swee
7、p generatorOscilloscope Digital voltmeterDistortion meter Isulating TransformerFe Test Cassette 3150Hz/10kHzGeneral NotesBefore opening the cabinet disconnect the mains plug!Attention: Observe the ESD safety regulations WiringBefore disconnecting any leads and especially the earth connectingleads ob
8、serve the way they are routed to the individual assemblies likethe chassis, mains switch panel, keyboard control panel, picture tubepanel, deflection unit, loudspeaker and so on.On completion of the repairs the leads must be laid out as originallyfitted at the factory to avoid later failures or dist
9、urbances.Carrying out MeasurementsWhen making measurements on semi-conductors with an oscillo-scope, ensure that the test probe is set to 10:1 dividing factor. If theprevious measurement was made on AC input, please note that thecoupling capacitor in the oscilloscope will be charged. Discharge viath
10、e item being checked can damage the components.Allgemeiner TeilMessgerte / MessmittelMess-Sender WobbelsenderOszilloskop DigitalvoltmeterKlirrfaktormessgert TrenntrafoFe-Test-Cassette 3150Hz/10kHzAllgemeine HinweiseVor dem ffnen des Gehuses zuerst den Netzstecker ziehen!Achtung: ESD-Vorschriften bea
11、chten LeitungsverlegungBevor Sie die Leitungen und insbesondere die Masseleitungen lsen,muss die Leitungsverlegung zu den einzelnen Baugruppen beachtetwerden.Nach erfolgter Reparatur ist es notwendig, die Leitungsfhrung wiederin den werkseitigen Zustand zu versetzen um evtl. sptere Ausflleoder Strun
12、gen zu vermeiden.Durchfhren von MessungenBei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nurTastkpfe mit 10:1 - Teiler verwenden. Auerdem ist zu beachten,dass nach vorheriger Messung mit AC-Kopplung der Koppelkonden-sator des Oszilloskops aufgeladen sein kann. Durch die Entladungber das