《Hafler-SE120-pwr-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《Hafler-SE120-pwr-sm维修电路图 手册.pdf(13页珍藏版)》请在收音机爱好者资料库上搜索。
1、THE Hafler SE120 POWER AMPLIFIER SERVICE MANUAL HAFLER A DIVISION OF ROCKFORD CORPORATlON 613 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 RadioFans.CN POWER AMPLIFIER SPECIFICATIONS POWER RATING: Less than 0.006% total harmonic distortion at any power level up to 60 watts continuous average power per
2、channel into 8 ohms at any frequency between 20 Hz and 20 kHz with both channels driven. IM DISTORTION (IHF): Less than 0.005% from 1 to 60 watts, each channel, into 8 ohms. TYPICAL THD AT 60 WATTS INTO 8 OHMS: 20 Hz: 0.002% 1 kHz: 0.002% 20 kHz: 0.006% FREQUENCY RESPONSE INTO 8 OHMS: -3dB, 4Hz to 2
3、OOkHz at 1 watt. +OdB, -0.5dB, 1OHz to 4OkHz at 60 watts. TYPICAL CHANNEL SEPARATION: 2OHz: 75dB 1kHz: 85 dB 20kHz: 65dB SIGNAL TO NOISE RATIO, UNWEIGHTED: Exceeds 1OOdB referred to 60 watts into 8 ohms. INPUT IMPEDANCE: 22,000 ohms INPUT SENSITIVITY: 1.1 volts rms for 60 watts into 8 ohms. DAMPING
4、FACTOR: 100to1kHzinto8ohms,50to1OkHzinto8ohms. POWER CONSUMPTION: 60 watts both channels into 8 ohms: 300 VA Quiescent: 60 VA SIZE: 3-1/4” high plus 1/2” feet, 17” wide, 9” deep. (83 mm high plus 152 mm, 432 mm wide, 229 mm deep.) NET WEIGHT: 18 lbs. (8.2 kg) SHIPPING WEIGHT: 20 lbs. (9.1 kg) Stereo
5、/Mono Channel Operation: The SE120 delivers 60 watts continuous average power per channel into 8 ohms. It can be bridged for single channel operation producing up to 120 watts of power into 16 ohms. Input Mode Selector: This switch will allow the user to specify the input signal to the amplifier. A.
6、 Stereo Mode: This allows the right and left channels to reach their designated amplifier channels. This mode will deliver more than 60 watts into an 8 ohm load. B. Mono Mode: The SE1 20 can be operated in a bridged mode which drives both channels with the same signal and combines to deliver more th
7、an 150 watts into 8 ohms. This disables the right channel input and routes the signal through the left channel. Construction: The simplified construction of the SE120 improves relia- bility and results in consistent performance. The heavy duty case construction on the SE120 will provide years of dur
8、ability and trouble free protection. Gold Plated RCA Input Connectors: This provides the most accurate signal transmission and lowest possible loss. Gold-plated terminals are immune to signal deterioration with time that can be caused by corro- sion in the connectors. Speaker Output and Power Connec
9、tors: For minimum loss power transfer, high definition and oxidization resistance. Protection System: The SE120 is equipped with a unique protection system that constantly monitors the temperature of the output devices and takes corrective action to prevent damage to the amplifier as a result of exc
10、essive overheating. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Copyright 1990. All rights reserved -l- RadioFans.CN RadioFans.CN LINE CONNECTIONS AND SWITCHING The SE120 is normally wired for use on 12OV AC power lines, as in the U.S.A. If your line voltage is different, you will need the
11、special Hafler export power transformer which accommodates many other line voltages. Be sure your amplifier is wired for your line voltage before you plug it in. The SEl2Os power switch may be left on, and the amplifier switched remotely by connecting its line cord to the preamplifier (or other cont
12、rol center) which provides a switched AC outlet. Make sure that the control device can supply a current of 5 amperes to the SE 120, in addition to the current required by any other switched units. You may instead connect the amplifier directly to a wall outlet, and control it with its own front pane
13、l power switch. CONNECTING CABLES GROUNDING: INPUT: Conventional shielded cables, often supplied with pre- amplifiers, may connect the control center to the amplifiers input jacks. Be sure the cables are not frayed or loosely connected to the plugs, and that the plugs outer shield connection is tigh
14、t on the jack, to avoid hum. If you wish to install the SE120 more than a few feet from the preampli- fier, the permissible cable length to avoid loss of high frequencies is determined by the preamplifiers output im- pedance and the internal capacitance of the cable. If the output impedance is 600 o
15、hms or less, as with Hafler preamplifiers, and the cable capacitance is less than 50 picofarads per foot, up to 50- feet is acceptable. Ordinary stereo interconnecting cables often have higher capaci- tance, however, so a good quality low capacitance shielded wire should be used. When making long ru
16、ns, keep the left and right cables close together, and avoid running them parallel to power wiring to reduce the likelihood of hum pickup. OUTPUT: The wires which connect the speakers to the amplifier should be of sufficient size to preserve the SEl2Os high damping factor. Standard #18 gauge lamp co
17、rd is satisfac- tory for up to 15 feet if your speakers are of 8 ohms or higher impedance. A heavier gauge (#16 or larger) wire should be used with 4 ohm speakers or 8 ohm speakers at a greater distance. Special loudspeaker cables which have adequate thickness to accommodate long runs are usually av
18、ailable from audio dealers. The SEl2Os red and black outputs accept standard banana plug connectors, including the double ones with 3/4” spacing. These are the most conven- ient to use if you will be disconnecting the speakers occa- sionally. The terminals will also clamp a spade lug, or a bare wire
19、 through the hole in the center post. Be sure there are no frayed wire ends which could touch adjacent terminals or the chassis. Tin bare wire ends with solder to secure all strands. PHASING: Consistent phase relationships are important when con- necting speakers in order to enable full bass reprodu
20、ction as well as midrange and high frequency time alignment. To be sure all speakers in a system are wired in phase to the amplifier, each ground or - speaker terminal should be connected to its black ground tenninal on the SE 120 and the speakers + terminal to the corresponding red binding post. Sp
21、eaker connecting cable identifies one wire from the other by the color of the wire, or by marking or coloring the insulation. NOTE: In the special case of monophonic operation of the SE 120, (described later) different speaker connections are employed. The black output terminals of the SE120 are con
22、nected together internally and grounded to the chassis. This facilitates the use of external devices which use a common ground connection, such as some headphone junctionboxes. You must be sure that the ground or shield connection from such a device goes to a black terminal on the SE1 20. NOTE: No s
23、uch connection may be made when the SE120 is connected for bridged mono operation. CONVENTIONAL STEREO CONNECTIONS It is best to make all connections with the SE120 switched off. Each of the stereo speakers connects to one horizontal pair of red and black outputs, as identified left or right on back
24、 of the SE 120. The input signals connect to the corresponding input jacks, and the mono/stereo switch should be set to stereo. CONNECTIONS FOR MONOPHONIC OPERATION When you wish to drive a single loudspeaker with increased power capability, the SE120 can be operated in a bridged mode which drives b
- 配套讲稿: