《Pioneer-DV79AVI-dvd-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-DV79AVI-dvd-sm维修电路原理图.pdf(108页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ORDER NO. PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01
2、, Singapore 159936 PIONEER CORPORATION 2005 ? DV-79AVi RRV3286 DVD PLAYER DV-79AVi DV-79AVi-S THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). ModelTypePower RequirementRegion No.Remarks DV-79AViKUXJ/CAAC120V1 DV-79AVi-SKUXJ/CAAC120V1 For details, refer to Important symbols for good
3、services. T-ZZR NOV. 2005 printed in Japan RadioFans.CN 收音机爱 好者资料库 DV-79AVi2 1234 1234 C D F A B E SAFETY INFORMATION This service manual is intended for qualified service technicians ; it is not meant for the casual do-it- yourselfer. Qualified technicians have the necessary test equipment and tool
4、s, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly
5、 and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to causecancer, birth defects or other reproductive harm. He
6、alth Location of the display: At the two digits of center of the FL display To display the error history: ESC + DISPLAY + One shot; Location of the display: TV screen RadioFans.CN 收音机爱 好者资料库 DV-79AVi88 1234 1234 C D F A B E FL Description of Error Causes if with a DVDCauses if with a CDOperation of
7、the Unit 39 SGC converge timeout SGC could not converge during detects the peakOpen 41Spindle timeout The unit did not enter Stop mode within 10 seconds of issuance of a Stop command. Disc distinction is not completed even if passes for 10 seconds after the spindle turned. Stop 48 Spindle FG transit
8、ion timeout Did not reach to the rotating speed that ATB was possible for less than 10 seconds. Did not reach aim CAV lock speed (high: 10%, low: 50%) for less than 10 seconds. CAV process passed more than 5 seconds or abnormal speed was detected. Spindle does not lock for less than 3 seconds in the
9、 BCA read start or end. Stops. (FG timeout) 49 Spindle PLL transition timeout CAV process passed more than 5 seconds. Abnormal speed was detected. Stops. (73 is displayed during starting process.) 4ASpindle lock timeoutSpindle could not lock more than 1.5 seconds before start the AFB. Stops. (73 is
10、displayed during starting process.) 51 Auto sequence timeout of peak detection ABUSY did not return within 1 second after the DDTCT (peak detection) command was sent. Stop 52 Auto sequence timeout of focus jump down ABUSY did not return within 30 mS after the FJMPD (Focus jump 1 to 0) command was se
11、nt. Open 53 Auto sequence timeout of focus jump up ABUSY did not return within 30 mS after the FJMPU (Focus jump 0 to 1) command was sent. Open 54 Auto sequence timeout of play AGC ABUSY did not return within 50 mS after the GSUMON (play-AGC-measuring) command was sent. Stop 55 Auto sequence timeout
12、 of disc-type- sensing ABUSY did not return within 2 seconds after the DJSRT (disc-sensing) command was sent. Stop 56 Auto sequence timeout of ATB2 ABUSY did not return within 1 second after the TBLOFS (Internal ATB after the completion of external ATB) command was sent. Stop 57 Auto sequence timeou
13、t of tracking servo ON ABUSY did not return within 0.5 sec. after the TSON (tracking servo ON) command was sent. Stop 58 Auto sequence timeout of ATB1 ABUSY did not return within 0.2 sec. after the TBL (external ATB) command was sent. Stop 59 Auto sequence timeout of focus gain adjustment ABUSY did
14、not return within 2 seconds after the FGN (focus gain adjustment) command was sent. Stop 5A Auto sequence timeout of tracking gain adjustment ABUSY did not return within 2 seconds after TGN (tracking gain adjustment) command was sent. Stop 5B Auto sequence timeout of offset adjustment ABUSY did not
15、return within 1 second after the AVE (offset adjustment) command was sent. Stop 5C Auto sequence timeout of modulation factor measurement ABUSY did not return within 200 mS after the ADJMIR (modulation factor measurement) command was sent. Stop 5D Auto sequence timeout of auto focus bias ABUSY did n
16、ot return within 2 seconds after the AFB (auto focus bias) command was sent. Stop 5F Auto sequence already busy A command could not be sent because ABUSY was low. ABUSY did not return within 200 mS after TLV command was sent. Stop 62Pause retry error Pause mode could not be restored within three ret
17、ries after it had been released. Continues operation 71 ID reading check during playback An ID could not be read for 1 second or more.Stop 72 Subcode check failure during playback No frame could be read for 3 seconds or more. Stop 73 ID can not read during startup An ID could not be read within 1 se
18、cond after the AFB tracking on. Opens (ID readout failure) RadioFans.CN 收音机爱 好者资料库 DV-79AVi89 5678 56 7 8 C D F A B E FL Description of Error Causes if with a DVDCauses if with a CDOperation of the Unit 74 Subcode check failure during startup Subcode could not be read within 1 second after the track
19、ing on. Opens (Subcode readout failure). A1 Communication timeout of DSP command A command could not be issued to DSP because Command Busy (XCBUSY) was in force (XCBUSY = L) for a specified time (about 200 S). Open A2 Communication timeout for reading DSP coefficient Command Busy (XCBUSY) was in for
20、ce for a specified time (about 200 S) before and after a coefficient read command was issued to DSP, or the address echo-back after command issuance did not match the setup address. Open A4 Communication timeout for continuously writing DSP coefficient Command Busy (XCBUSY) was in force for 200 S du
21、ring continuous coefficient writing, or before and after a continuous write command was issued to DSP. Open B1 Timeout error for backup In the backup sequence, codes could not be read for fixed time.Stops B2 Retry error for backup Cannot close tracking even if performs backup fixed number of times.S
22、tops B3Retry error for trace During tracing, do not restore after the runaway detection backup was performed several times. Stops C3 Detection of tracking overcurrent During playback, the overcurrent detection port was at L for 300 ms or more continuously. Stops (the mechanical controller operates i
23、ndependently). (C5) Short-circuit test corresponding error After the overcurrent detection (C3 error), furthermore the overcurrent detection port was at L for 300 mS or more continuously. Turns off the power instantly (No indication on the FL display and no writing to flash memory) F5Tray being push
24、ed The tray switch that had been Open mode was forcibly changed to a mode other than Open by an external force. Closes F6Code reading NG (PH code nothing) When Philips code is not readable during LD starting, and a code was not readable after the slider moved to FWD and REV directions slowly each fo