《Pioneer-VSX519VS-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-VSX519VS-avr-sm维修电路原理图.pdf(94页珍藏版)》请在收音机爱好者资料库上搜索。
1、ORDER NO. PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium 2009 Printed in Japan VSX-519V-K RRV3897 AUDIO/VIDEO MULTI-CHANNEL R
2、ECEIVER VSX-519V-K VSX-519V-S THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). ModelTypePower RequirementRemarks VSX-519V-KMYSXCN5AC 220 V to 230 V VSX-519V-SMYSXCN5AC 220 V to 230 V For details, refer to Important Check Points for good servicing. T-ZZK MAR, RadioFans.CN 收音机爱 好者资料库 2
3、VSX-519V-K 1234 A B C D E F 1234 SAFETY INFORMATION NOTICE (FOR CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical designation. REMARQUE (POUR MODLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de t
4、ype rapide) et/ou (fusible de type lent) sur CCI indiquent que les pices de remplacement doivent avoir la mme dsignation. This service manual is intended for qualified service technicians; it is not meant for the casual do-it-yourselfer. Qualified technicians have the necessary test equipment and to
5、ols, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product proper
6、ly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING This product may contain a chemical known to the State of California to cause cancer, or birth defects or other reproductive harm. Health 5,956,674; 5,974,380; 5,978,762; 6,226,616; 6,4
7、87,535 * When connected the equipment to IN1 (BD/DVD); * When connected the equipment to IN3 (DVR/VCR) Is the voltage 5 V when selecting IN2? Is the voltage 5 V when selecting IN3? JACK1003 (Pin 18)+5V_R3 Is the voltage 5 V? Is the voltage 5 V? Is the voltage 5 V? Is the voltage 5 V? Check the JACK1
8、003. If JACK 1003 is failure, replace JACK1003. Check the JACK1001. If JACK 1001 is failure, replace JACK1001. Check the JACK1002. If JACK 1002 is failure, replace JACK1002. Yes JACK1002 (Pin 18)+5V_R2 Yes No No JACK1001 (Pin 18) No +5V_R1 Yes * When connected the equipment to IN1(BD/DVD); Check the
9、 JACK1001 and IC1001. If JACK1001 or IC1001 is failure, replace JACK1001 or IC1001. No Yes Is the voltage 5 V when selecting IN1? To Step 7 To Step 6 Step 5: IN/OUTPUT DiagnosisStep 6: Hot plug detect RadioFans.CN 收音机爱 好者资料库 29VSX-519V-K 5678 5678 A B C D E F IC1002 (Pins 30,31,33,34,36,37,39,40)TMD
10、S OUTPUT SDA (HDMI IN2 (TV/SAT) No IC1001 (Pin 40) Is there a same signal as IC1002-pin 49 when selecting IN2? Yes Check the IC1001 and JACK1002. If IC1001 or JACK1002 is failure, replace IC1001 or JACK1002. * When connected the equipment to IN2 (TV/SAT): SCL (HDMI IN2 (TV/SAT) No IC1001 (Pin 39) Is
11、 there a same signal as IC1002-pin 48 when selecting IN2? Yes Check the IC1001 and JACK1002. If IC1001 or JACK1002 is failure, replace IC1001 or JACK1002. Check the IC1001 or IC1002. If IC1001 or IC1002 is failure, replace IC1001 or IC1002. (0 to 5 V) (0 to 5 V) End No Are there signals(approx. 0.5
12、Vp-p) in all lines? Yes Step 8: TMDS SDA (HDMI IN3 (DVR/VCR) No IC1001 (Pin 36) Is there a same signal as IC1002-pin 49 when selecting IN3? Yes Check the IC1001 and JACK1001. If IC1001 or JACK1001 is failure, replace IC1001 or JACK1001. * When connected the equipment to IN3 (DVR/VCR): SCL (HDMI IN3
13、(DVR/VCR) No IC1001 (Pin 35) Is there a same signal as IC1002-pin 48 when selecting IN3? Yes Check the IC1001 and JACK1001. If IC1001 or JACK1001 is failure, replace IC1001 or JACK1001. (0 to 5 V) (0 to 5 V) To Step 8 IC1002 (Pin 47)SDA (HDMI OUT) SDA (HDMI IN1(BD/DVD) Does a signal output in consta
14、nt period (0 to 5 V) ? Check the JACK1004 and IC1002. If JACK1004 or IC1002 is failure, replace JACK1004 or IC1002. No No No Yes IC1002 (Pin 46)SCL (HDMI OUT) Does a clock output in constant period (0 to 5 V) ? Check the JACK1004 and IC1002. If JACK1004 or IC1002 is failure, replace JACK1004 or IC10
15、02. Yes IC1001 (Pin 44) Is there a same signal as IC1002-pin 49 when selecting IN1? Yes Check the IC1001 and JACK1003. If IC1001 or JACK1003 is failure, replace IC1001 or JACK1003. * When connected the equipment to IN1(BD/DVD); SCL (HDMI IN1(BD/DVD) No IC1001 (Pin 43) Is there a same signal as IC100
16、2-pin 48 when selecting IN1? Yes Check the IC1001 and JACK1003. If IC1001 or JACK1003 is failure, replace IC1001 or JACK1003. SDA_SINK No No SCL_SINK IC1002 (Pin 49) Is there a same signal as IC1001-pin 24 (0 to 3.3V) ? Yes Check the IC1002 and IC1001. If IC1002 or IC1001 is failure, replace IC1002
17、or IC1001. Check the IC1002 and IC1001. If IC1002 or IC1001 is failure, replace IC1002 or IC1001. IC1002 (Pin 48) Is there a same signal as IC1001-pin 23 (0 to 3.3V) ? Yes (0 to 5 V) (0 to 5 V) Step 7: SDA /SCL RadioFans.CN 收音机爱 好者资料库 30VSX-519V-K 1234 A B C D E F 1234 5.2 DETECTION CIRCUIT 1 DC Pro
18、tection Circuit Diagram P.C.B SUB ASSY (MAIN)A P.C.B SUB ASSY (SPEAKER) M P.C.B SUB ASSY (P/T)BP.C.B SUB ASSY (AMP)J RadioFans.CN 收音机爱 好者资料库 31VSX-519V-K 5678 5678 A B C D E F 2 Overload Protection Circuit Diagram P.C.B SUB ASSY (MAIN)AP.C.B SUB ASSY (P/T)BP.C.B SUB ASSY (AMP)J RadioFans.CN 收音机爱 好者资
19、料库 32VSX-519V-K 1234 A B C D E F 1234 3 Power DC Protection Circuit Diagram P.C.B SUB ASSY (MAIN)A P.C.B SUB ASSY (P/T)B RadioFans.CN 收音机爱 好者资料库 33VSX-519V-K 5678 5678 A B C D E F 6. SERVICE MODE 6.1 SERVICE MODE 1 Display mode for numbers of protection detections Purpose Basic operations FL Display
20、Description of IndicationsKey Operation (STANDBY state) PRESET + STANDBY/ON (Initial display) ENTER key ENTER key ENTER key (Initial display) 5 (- normal) *1 5 (- normal) *1 5 (- normal) *1 Number of DC error detections Number of OVERLOAD error detections Number of abnormal-temperature error detecti
21、ons Time (sec.) The numbers of detections for various protection processes are displayed. *1 “5 (- normal)” denotes that the display will return to the normal indication when no key operation is performed for 5 seconds. *2 Variable range: 0-255 How to enter/exit During Standby mode, simultaneously p
22、ress and hold the PRESET and STANDBY/ON keys for 2 seconds to enter this mode. The display will return to the normal indication when no key operation is performed for 5 seconds. Counter Counter Counter *2 *2 *2 RadioFans.CN 收音机爱 好者资料库 34VSX-519V-K 1234 A B C D E F 1234 2 Reset mode for numbers of pr
23、otection detections Purpose Basic operations FL DisplayDescription of IndicationsKey Operation (STANDBY state) STANDARD SURROUND + STANDBY/ON (press and hold the keys for 10 seconds.) (Counter Clear end) ENTER key (Normal display) 5 (- normal) *1 5 (- normal) *1 usually *2 Time (sec.) For clearing a
24、ll the counts of protection detections. (This mode resets the counts of protection detections.) 1. When the procedures for Reset mode for numbers of protection detections are completed, all the counters will be reset to “000.” 2. Prohibitions: The protection detection counts cannot be cleared (reset
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Pioneer VSX519VS avr sm 维修 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
Pioneer-VSX519VS-avr-sm维修电路原理图.pdf



Pioneer-A90-Service-Manual电路原理图.pdf


