Fostex-CR200-cd-sm维修电路原理图.pdf
《Fostex-CR200-cd-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Fostex-CR200-cd-sm维修电路原理图.pdf(92页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service Manual Compact Disc Recorder CR200 Model DANGER - LASER RADIATION WHEN OPEN. AVOID DIRECT EXPOSURE TO BEAM. RadioFans.CN 收音机爱 好者资料库 SAFETY INSTRUCTIONS Read instructions - All the safety and operating instruc- tions should be read before the appliance is operated. Retain instructions - The s
2、afety and operating instructions should be retained for future reference. Heed warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not b
3、e used near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufac- turer. An appliance and cart combination shoul
4、d be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to over- turn. Wall or Ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation - The appliance should be situated
5、so that its location or position does not interfere with its proper ven- tilation. For example, the appliance should not be situ- ated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installa- tion, such as a bookcase or cabinet that may impe
6、de the flow of air through the ventilation openings. Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. Power Sources - The appliance should be connected to a power supply only of the
7、 type described in the operating instructions or as marked on the appliance. Grounding or Polarization - The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated. Power Cord Protection - Power supply cords should be routed so that they are not
8、likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep- tacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as rec- ommended by the manufacturer. Nonuse Periods - T
9、he power cord of the appliance should be unplugged from the outlet when left unused for a long period of time. Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the en- closure through openings. Damage requiring Service - The appliance should
10、 be ser- viced by qualified service personnel when: A. B. C. D. E. Servicing - The user should not attempt to service the ap- pliance beyond that described in the operating instruc- tions. All other servicing should be referred to qualified service personnel. REFER SERVICING TO QUALIFIED SERVICE PER
11、SONNEL. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. POUR VITER LES CHOCS LECTRIQUES, INTRODUIRE LA LAME LA PL
12、US LARGE DE LA FICHE DANS LA BORNE CORRE- SPONDANTE DE LA PRISE ET POUSSER JUSQU AU FOND. CAUTION: ATTENTION: The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte- nance (servicing) instructions in the literature accompa
13、nying the appliance. The lightening flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products en- closure that may be of sufficient magnitude to constitute a risk of electric shock to persons. “WA
14、RNING” “TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS- TURE.” 1. 2. 3. 4. 5. 6. 7. 8. The power supply cord or the plug has been damaged; or Objects have fallen, or liquid has been spilled into the appliance; or The appliance has been exposed to rain; or
15、The appliance does not appear to operate normally or exhibits a marked changed in performance; or The appliance has been dropped, or the enclosure damaged. 9. 10. 11. 12. 13. 14. 15. 16. 17. RadioFans.CN 收音机爱 好者资料库 3 CR200 TABLE OF CONTENTS Parts marked with this sign are safety critical components.
16、 They must always be replaced with identical components. Refer to the Fostex Parts List and ensure exact replacement. ! CAUTION 4 7 10 12 39 65 77 85 1. CD-R THEORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . .
17、 . . . . . . . . . . . . . . . . . . . 3. CONTROLS, INDICATORS & CONNECTORS . . . . . . . . . . . . . . . . . 4. ADJUSTING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. ADDITIONAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . 6. EXPLODED VIEW, PCB ASSEMBLY & P
18、ARTS LIST . . . . . . . . 7. CIRCUIT & BLOCK DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . 8. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NOTES Adjusting procedures are given in this manual which also includes a Parts List and circuit diagrams to assist th
19、e service technician in maintaining the Model CR200. The following accessory is supplied with CR200 as a standard. * * Following is the packing material for the Model CR200. Carton, inner, CR200: 8228718000 Carton, outer, CR200: 8228897000 Packing, L, CR200: 8228443000 Packing, R, CR200: 8228444000
20、* Owners manual, CR200: 8288407000 (for export model) Remote control unit Model 8317: 8270829000 Audio cable (L : 1.2m): 8276912000 Power cable: 8276910000 (for USA model) : 8276911000 (for EUR model) RadioFans.CN 收音机爱 好者资料库 4 CR200 1. CD-R THEORY 1-1. Physical layout compared to CD The conventional
21、 CD and CD-R discs basically have the same physical layout. However, as you can see from the Fig. 1, comparing to the conventional CD, the CD-R disc also has so- called “minus” areas such as PCA (Power Calibration Area) and PMA (Program Memory Area) where the temporary information is recorded. Unrec
22、orded, blank disc The information area is located next to the clamping area and the center hole. This area contains a pregroove with CLV (Constant Linear Velocity) clocking information and a time code. Partially recorded disc The CD-R system gives the opportunity to record a disc in several actions
23、at a different time on a different recorder. After the first recording, the information area is divided into five parts as shown below and in the right. 1: Power Calibration Area (PCA) 2: Program Memory Area (PMA) 3: Lead-in Area 4: Program Area 5: Lead-out Area Finalized disc After finalizing the d
24、isc, the CD-R disc will become compatible with the RED Book (for regular CD) definitions and specifications. Therefore, it can be played back on conventional CD players. The Information Area of a finalized disc consists of three parts: 1: Lead-In Area 2: Program Area 3: Lead-Out Area Fig. 1 Cross Se
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Fostex CR200 cd sm 维修 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf