JVC-MXKC45-cs-sm维修电路原理图.pdf
《JVC-MXKC45-cs-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-MXKC45-cs-sm维修电路原理图.pdf(71页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2006 Victor Company of Japan, Limited No.MB550 2006/7 COMPACT COMPONENT SYSTEM MB55020067 MX-KC45E,MX-KC45EN, MX-KC45A,MX-KC45UW, MX-KC45UY,MX-KC45UJ Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 3DISASSEMBLY .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
4、12 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 CA-MXKC45SP-MXKC45SP-MXKC45 RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB550) SPECIFICATION Design and specifications are subject to change without notice.
5、AmplifierOutput Power(IEC 268-3)155 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 10% total harmonic distortion (DIN-3)125 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 0.9% total harmonic distortion Input Sensitivity/ Impedance (1 kHz) AUX IN Speaker terminal
6、s 400 mV/50 k 6 - 16 Phones32 - 1 k 17 mW/ch output into 32 Cassette Deck Section Frequency Response : Type I (NORMAL) 63 Hz - 12 500 Hz Wow And Flutter0.15% (WRMS) CD PlayerCD Capacity3 CDs Dynamic Range85 dB Signal-To-Noise Ratio85 dB Wow And FlutterUnmeasurable TunerFM Tuner : Tuning Range87.50 M
7、Hz - 108.00 MHz 87.50 MHz - 108.00 MHz (at AM9 kHz channel space) 87.5 MHz - 108.0 MHz (at AM10 kHz channel space) AM Tuner : Tuning Range522 kHz - 1710 kHz 522 kHz - 1 629 kHz (for Europe) 531 kHz - 1710 kHz (at AM9 kHz channel space) 530 kHz - 1710 kHz (at AM10 kHz channel space) UnitDimensions270
8、 mm 307 mm 492 mm (W/H/D) MassApprox. 9.3 kg Speaker Specifications (each unit) Type3-way bass-reflex type Speaker UnitWoofer16 cm cone 1 Mid5cm cone 1 Tweeter2cm dome 1 Power Handling Capacity160 W Impedance6 Frequency Range45 Hz - 22 000 Hz Sound pressure level87 dB/Wm Dimensions220 mm 324 mm 238
9、mm (W/H/D) MassApprox. 3.6 kg Power SpecificationsPower RequirementsAC 240 V , 50 Hz (for Australia) AC 230 V , 50 Hz (for Europe) AC 110 V-127 V/220 V-240 V , adjustable with voltage selector, 50 Hz/60 Hz (for Asia) Power Consumption165 W (power on mode) 23 W (in Standby mode) 1 W (in ECO mode) Rad
10、ioFans.CN 收音机爱 好者资料库 (No.MB550)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in wr
11、iting by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. A
12、ny design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These c
13、haracteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List
14、 of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the
15、 Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock
16、 and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exp
17、osed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into t
18、he AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check me
19、thod Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage a
20、cross the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage meas
21、ured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) R
22、epairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts
23、of the chassis. Therefore, pay attention to such burrs in the case of pre- forming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the res
24、istor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each expo
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC MXKC45 cs sm 维修 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。