1、1 SERVICE MANUALUS Model Canadian Model AEP Model STR-DE197 FM STEREO/FM-AM RECEIVER AUDIO POWER SPECIFICATIONS POWER OUTPUT AND TOTAL HARMONIC DISTORTION: (Models of area code US only) With 8 ohm loads, both channels driven, from 20 20,000 Hz; rated 100 watts per channel minimum RMS power, with no
2、more than 0.09 % total harmonic distortion from 250 milliwatts to rated output. Amplifier section POWER OUTPUT Models of area code US, CND Power Output at Stereo Mode (8 ohms 1 kHz, THD 0.7 %) 125 W + 125 W 1) Models of area code AEP Power Output at Stereo Mode (8 ohms 1 kHz, THD 0.7 %) 100 W + 100
3、W 1) 1) Measured under the following conditions: Area codePower requirements US, CND120 V AC, 60 Hz AEP230 V AC, 50 Hz Frequency response CD, MD/TAPE,20 Hz 50 kHz VIDEO 1, 2+0/0.5 dB (with bass boost and tone bypassed) Inputs (Analog) CD, MD/TAPE,Sensitivity: 500 mV VIDEO 1, 2Impedance: 50 kilohms S
4、/N 2) : 85 dB (A, 500 mV 3) ) 2) INPUT SHORT (with bass boost and tone bypassed). 3) Weighted network, input level. SPECIFICATIONS Outputs (Analog) MD/TAPE (OUT),Voltage: 500 mV VIDEO 1 (AUDIO OUT)Impedance: 10 kilohms Bass Boost:+8 dB at 70 Hz Tone:10 dB at 100 Hz and 10 kHz FM tuner section Tuning
5、 range87.5 108.0 MHz AntennaFM wire antenna Antenna terminals75 ohms, unbalanced Intermediate frequency10.7 MHz Sensitivity Mono:18.3 dBf, 2.2 V/75 ohms Stereo:38.3 dBf, 22.5 V/75 ohms Usable sensitivity11.2 dBf, 1 V/75 ohms S/N Mono:76 dB Stereo:70 dB Harmonic distortion at 1 kHz Mono:0.3% Stereo:0
6、.5% Separation45 dB at 1 kHz Frequency response30 Hz 15 kHz, +0.5/2 dB Selectivity60 dB at 400 kHz Ver. 1.2 2006. 02 9-877-864-03 2006B04-1 2006. 02 Sony Corporation Home Audio Division Published by Sony Techno Create Corporation Continued on next page Photo: Black type RadioFans.CN 收音机爱 好者资料库 2 STR
7、-DE197 AM tuner section Tuning range Models of area code US, CND With 10-kHz tuning scale: 530 1,710 kHz 4) With 9-kHz tuning scale:531 1,710 kHz 4) Models of area code AEP With 9-kHz tuning scale:531 1,602 kHz AntennaLoop antenna Intermediate frequency450 kHz Usable sensitivity50 dB/m (at 1,000 kHz
8、 or 999 kHz) S/N54 dB (at 50 mV/m) Harmonic distortion0.5 % (50 mV/m, 400 Hz) Selectivity At 9 kHz:35 dB At 10 kHz:40 dB 4) You can change the AM tuning scale to 9 kHz or 10 kHz. After tuning in any AM station, turn off the receiver. Hold down PRESET TUNING + and press ?/1. All preset stations will
9、be erased when you change the tuning scale. To reset the scale to 10 kHz (or 9 kHz), repeat the procedure. General Power requirements Area codePower consumption US, CND120 V AC, 60 Hz AEP230 V AC, 50/60 Hz Power consumption Area codePower consumption US190 W CND270 VA AEP210 W Power consumption (dur
10、ing standby mode) 0.5 W AC outlets Area codeAC outlets US, CND1 switched, 120 W/1A MAX AEP1 switched, 100 W MAX Dimensions430 132.5 302 mm (17 5 1/4 11 7/8 inches) including projecting parts and controls Mass (Approx.)7.0 kg (15 lb 7 oz) Supplied accessories FM wire antenna (1) AM loop antenna (1) R
11、emote commander RM-U185 (1) R6 (size-AA) batteries (2) Design and specifications are subject to change without notice. Abbreviation CND: Canadian model 1.5 k0.15 F AC voltmeter (0.75 V) To Exposed Metal Parts on Set Earth Ground Fig. A. Using an AC voltmeter to check AC leakage. SAFETY CHECK-OUT Aft
12、er correcting the original service problem, perform the following safety check before releasing the set to the customer: Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. LEAKAGE TEST The AC leakag
13、e from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA
14、WT-540A. Follow the manufacturers instructions to use these instruments. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indicati
15、on is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A) SAFETY-RELATED COMPONENT WARNING! COMPONENTS I
16、DENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. ATTENTION AU COMPOSANT AYANT RAPPORT LA SCURI
17、T! LES COMPOSANTS IDENTIFIS PAR UNE MARQUE 0 SUR LES DIAGRAMMES SCHMATIQUES ET LA LISTE DES PICES SONT CRITIQUES POUR LA SCURIT DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PICES SONY DONT LES NUMROS SONT DONNS DANS CE MANUEL OU DANS LES SUPPLMENTS PUBLIS PAR SONY. RadioFans.CN 收音机爱 好者
18、资料库 3 TABLE OF CONTENTS 1. GENERAL Main unit . 4 Remote button description. 6 2. DISASSEMBLY 2-1. Case . 7 2-2. Front Panel Section . 8 2-3. Back Panel. 8 2-4. Main Board . 9 3. TEST MODE. 10 4. DIAGRAMS 4-1. IC Pin Description. 11 4-2. Circuit Boards Location . 13 4-3. Block Diagram Main Section .1
19、5 4-4. Block Diagram Power Section . 16 4-5. Printed Wiring Boards Main Section .17 4-6. Schematic Diagram Main Section (1/2) .18 4-7. Schematic Diagram Main Section (2/2) .19 4-8. Printed Wiring Boards Panel Section .20 4-9. Schematic Diagram Panel Section .21 4-10. IC Block Diagrams. 22 5. EXPLODE
20、D VIEWS 5-1. Case Section .23 5-2. Front Panel Section .24 5-3. Chassis Section . 25 6. ELECTRICAL PARTS LIST. 26 STR-DE197 MODEL IDENTIFICATION BACK PANEL Part No. MODELPART No. US4-253-299-0s AEP4-253-299-1s CND4-253-299-3s Abbreviation CND: Canadian model 4 STR-DE197 SECTION 1 GENERALThis section
21、 is extracted from instruction manual. 5 STR-DE197 6 STR-DE197 7 STR-DE197 Note : This set can be disassemble according to the following sequence. SECTION 2 DISASSEMBLY 2-1. CASE 2-1.CASE (Page 7) 2-2.FRONT PANEL SECTION (Page 8) 2-3.BACK PANEL (Page 8) SET 2-4.MAIN BOARD (Page 9) Note : Follow the
22、disassembly procedure in the numerical order given. 1 two screws (case 3 TP2) 2 two screws (case 3 TP2) 3 two screws (case 3 TP2) 4 case 8 STR-DE197 2-2. FRONT PANEL SECTION 2-3. BACK PANEL 6 front panel section 4 two screws (BVTP3 x 8) 1 CNS2 2 CNS3 3 CNP801 5six screws (BVTP3 x 8) 1 connector 2 CN