1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2512004/6POWERED SUB WOOFERMB25120046SP-DWF10TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SE
2、RVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64ADJUSTMENT .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-95TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10Are
4、a suffixJ - U.S.A.A - AustraliaE - Continental EuropeUS - SingaporeUF - ChinaUP - KoreaUT - TaiwanUX - Saudi ArabiaUJ - U.S.MilitaryRadioFans.CN 收音机爱 好者资料库1-2 (No.MB251)SPECIFICATIONDesign and specifications are subject to change without notice.TypePowered Subwoofer Bass-reflex type (magnetically sh
5、ielded type)Speaker16.0 cm cone 1 (6-5/16)Frequency Range32 Hz 200 HzImpedance4 Input terminalsINPUT (LOW-LEVEL)Power requirementsAC 120 V , 60 HzOutput power of built-in amp100 W (45 Hz, 4 , 10 % THD)Power Handling Capacity25 WDimensions (W H D)185 mm 374 mm 345 mm (7-5/16 14-3/4 13-5/8)Mass8.86 kg
6、 (19.6 lbs)RadioFans.CN 收音机爱 好者资料库(No.MB251)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized
7、 in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. A
8、ny design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These charac
9、teris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vi
10、ce Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of S
11、ervice Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When
12、 service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the prod
13、uct (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Cur
14、rent Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly in
15、to the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Mo
16、ve the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This
17、 corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafe
18、ty standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the c
19、ase of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are
20、 criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)150
21、0 10W0.15 F AC TYPE1-4 (No.MB251)1.5Importance administering point on the safetyCaution: For continued protection against risk of fire,replace only with same type 3 A/125 V for F901. This symbol specifies the type of fast operating fuse.Precaution: Pour la protection continue contre lesrisques dince
22、ndie, remplacer uniquement par lememe type: fusible 3 A/125 V pour les F901. Ce symbole specifie le type de fusible a action rapide. Power switch boardF9001(No.MB251)1-5SECTION 2SPECIFIC SERVICE INSTRUCTIONSThis service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.1-6 (No.MB251)SECTION 3DI
23、SASSEMBLY3.1Removing the Amplifier assembly (See Figs.1 and 2)(1) From the back side of the main body, remove the elevenscrews A attaching the amplifier assembly. (See Fig.1.)(2) Take out the amplifier assembly from the main body.(3) Disconnect the wire connector from the back side of theamplifier a
24、ssembly. (See Fig. 2.)(4) Disconnect the speaker wire from the speaker terminal.(See Fig.2.)3.2Removing the back panel (See Figs.1 to 3)(1) From the back side of the main body, remove the elevenscrews A attaching the amplifier assembly. (See Fig.1.)Reference:Remove the amplifier assembly from the ma
25、in body asrequired. (See Fig.2.)(2) Remove the five screws B attaching the back panel. (SeeFig.3.)Fig.1Fig.2Fig.3AAAAmplifier assemblyAAAmplifier assemblySpeaker terminalWire connectorBB(No.MB251)1-73.3Removing the power cord (See Figs.4 and 5) Prior to performing the following procedures, remove th