1、SERVICE MANUALRM-P210U/RM-P210EREMOTE CONTROL UNITNo. 60136April 2001COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD.Printed in Japan(V.P.) A.IVICTOR COMPANY OF JAPAN, LIMITED100% recycled paperRM-P210U/RM-P210ENo. 60136CALLTALLYINTERCOMLEVELFULL AUTOF1SHUTTERGAINF2F3MENU/SHUTTERGAINPAINTAUTOBRW.BALAUTO
2、MANUWHITEMASTER BLACKPOWERIOIRISSTEPSHUTTERMENUPUSH-ONDOWNUPVARIABLEPUSH-ONHIGHLOWBAPRESETCLOSEOPENMIDDOWNUPF4BARSREMOTE CONTROL UNIT RM-P210RadioFans.CN 收音机爱 好者资料库TABLE OF CONTENTSIIMPORTANT SAFETY PRECAUTIONSIINSTRUCTIONS1. SERVICE CAUTIONS AND DISASSEMBLY . 1-11.1REMOVAL OF EXTERNAL COVER. 1-11.2
3、FUNCTIONS AND SETTINGS OF INTERNAL SWITCHES. 1-21.3ADJUSTMENT AND CHECK MODES . 1-32. ELECTRICAL ADJUSTMENT . 2-12.1INSTRUMENTS REQUIRED FOR ADJUSTMENTS, THEIR SETUPS . 2-12.2ADJUSTMENT MODE. 2-22.3TRANSMIT VOLTAGE ADJUSTMENT . 2-32.4COMPOSITE SIGNAL OUTPUT ADJUSTMENT. 2-32.5COMPONENT/RGB SIGNAL OUT
4、PUT ADJUSTMENT . 2-42.6INTERCOM LEVEL ADJUSTMENT . 2-53. CHARTS AND DIGRAMS. 3-13.1MAIN/FR1/FR2/CC/SUB1 BOARD SCHEMATIC DIAGRAM 01 / 02 / 03 / 04 / 05 . 3-13.2MAIN CIRCUIT BOARD 01 . 3-23.3FR1 CIRCUIT BOARD 02 . 3-23.4FR2 CIRCUIT BOARD 03 . 3-23.5CC CIRCUIT BOARD 04 . 3-23.6SUB1 CIRCUIT BOARD 05. 3-
5、23.7IC BLOCK DIAGRAM. 3-34. EXPLODED VIEW AND PARTS LIST . 4-14.1RM-P210 ASSEMBLY M2 . 4-15. ELECTRICAL PARTS LIST. 5-15.1MAIN BOARD ASSEMBLY PARTS LIST 01. 5-25.2FR1 BOARD ASSEMBLY PARTS LIST 02. 5-75.3FR2 BOARD ASSEMBLY PARTS LIST 03. 5-85.4CC BOARD ASSEMBLY PARTS LIST 04 . 5-85.5SUB1 BOARD ASSEMB
6、LY PARTS LIST 05. 5-86. PACKING . 6-16.1PACKING ASSEMBLY M1. 6-1RadioFans.CN 收音机爱 好者资料库1-1SECTION 1SERVICE CAUTIONS AND DISASSEMBLY1.1REMOVAL OF EXTERNAL COVERDFEECCDAEABBAABCFCDRemove these 2screws to removethe front panel.Remove these 2 screwsto remove the front panel.Remove these 12 screwsto remo
7、ve the rear panel.1-2No.1MVONOFFS1S603CARBONDYNAMICS601S602RTS2W1.2FUNCTIONS AND SETTINGS OF INTERNAL SWITCHES1.2.1MAIN Board1.2.2CC BoardSet switches S35 and S36 according to the connected camera cable.MAIN Board (Rear Side)CC BoardS1U model:No. 1 OFFNo. 2 OFFE model:No. 1 ONNo. 2 OFF8-segment DIP
8、switch to be setaccording to the destination type.No. 1 ON : PAL. OFF: NTSCNo. 2 ON: Japan OFF: USANos. 3 to 8: Not used. (Set to OFF.) S601U model: ME model: VTally input M/V switchM: Make contact (ON when shorted)V: Voltage (ON when AC or DC is applied)SymbolFunctionFactory SettingS602U model: RTS
9、E model: 2WIntercom headset 2W/RTS switch.2W: 2-wire intercomRTS: RTS intercomS603DYNAMICIntercom headset microphoneDYNAMIC/CARBON switch. SymbolFunctionFactory SettingS35S36All ONAll OFFAll OFFAll ONAll OFFAll ONSymbolSony CableCCZ-A100 (100 m)JVC CableFactory SettingS35S36ONOFFONOFF1-31.3ADJUSTMEN
10、T AND CHECK MODES1.3.1Starting the Service Modes and Front Panel Check ModeThe RM-P210 incorporates the following service modes for use in servicing. Each of the service modes can be entered at the sametime as turning the RM-P210 ON and continues until it is turned OFF. Communications with the camer
11、a are not performed except inthe normal mode.The following table shows the names of the modes and their details.1.3.2Data Clear ModeStartup methodHold the FULL AUTO , BARS and IRIS buttons simultaneously while press the POWER switch.Operation DetailsWhen the unit is started in the Data Clear mode, a
12、ll EEPROM and SRAM data is initialized and the following message appears inthe LCD. After this, all operations are inhibited.Normal Data ClearHardware CheckAdjustmentAny other method than those described below.Hold FULL AUTO , BARS and IRIS buttons simultaneously while turning power ON.Hold CALL , F
13、1 and F2 buttons simultaneously while turning power ON.Hold MENU , F3 and F4 buttons simultaneously while turning power ON.This mode starts in normal operation by user.All EEPROM and SRAM data are initialized.Displays the program version.Check of LEDs, SW, VR, JOG dials, etc.For adjustments of suppl
14、y voltage and cable length.Mode NameStartup MethodContentsDATA CLEARED! !*HOW TO SET IT FOR USING SONY CABLE CCZ-A100.Sony cable can be used by changing the setting as below only when RM-P210 is connected with GY-DV550. Sony has many type ofthe cables but we can not check all the cable. Please do no
15、t use other than CCZ-A100.1. GY-DV550 settingChange the connection of the connector CN77 to CN83 on 56 CN board.2. RM-P210 setting(1) Change the setting of the switch on CC boarda) S35 : All switch have to be set to ON (UP side).b) S36 : All switch have to be set to OFF (DOWN side).(2) Re-adjustment
16、 of the transmit voltage (see “2.3 TRANSMIT VOLTAGEADJUSTMENT)After re-adjustment, check the voltage between pin A and pin B in 26Pconnector of RM-P210. It MUST be less than 15V. If it was more than15V, adjustment of the b) and c) (+17V and +19V adjustment) have tore-adjust to 15V from 16V.a) +15V s
17、upply adjustment : adjust to 15 0.2VDCb) +17V supply adjustment : adjust to 16 0.2VDCc) +19V supply adjustment : adjust to 16 0.2VDCNote 1: If the Voltage was not readjusted the View Finder will be damaged due to the heating problem.Note 2: Difference between Sony cable and JVC cable is the impedanc
18、e.JVC cable: 1.3 OhmSony cable: 0.8 Ohm.CN77CN831-41.3.3Hardware Check ModeStartup methodHold the CALL , F1 and F2 buttons simultaneously while pressing the POWER switch.The LEDs other than TALLY lights.When the unit is turned ON, the LCD shows the program number and software version as shown below
19、(initial display).The LCD also shows the results, either OK or NG, of the EEPROM and SRAM checking executed at the moment the unit is turnedON.The SRAM check consists of verifying the data retention status at the moment the unit is turned ON. The SRAM is backed up bya super-capacitor. Therefore, “NG
20、” is displayed even when the back-up power supply is down.The initial display above disappears when any of the operations accompanied with the LCD display, described on the next page, isexecuted.To view the initial display again, press the CALL button.Operation detailsTurning a button or terminal ON
21、 or OFF causes an operation as described below. The switches can be checked by turning the LEDson or off. All LEDs are turned off at the moment the unit is turned ONCV13.59 EPSRROAMMOOKKProgram No.EEPROM check result OK/NGVersionModel type Japan: I USA: U Europe: ESRAM check result OK/NGEach press o
22、f this button should turn the LED on/off and the initial display appears when it is on.The green LED should light when TALLY PVW on the rear panel is Active and the red should light when TALLY PGM is Active. Only the red LED should light when both tallies are Active.No LED should light when no talli
23、es are Active.Buttons/LEDsCALLTALLYRear-panelterminal/LEDCheck Point Check DetailsRemarkFULL AUTOBARSF1 to F4MENUSHUTTER JOGV.GAIN JOGPAINT (WHITE)AUTO (WHITE)IRISEach press of this button should turn the LED on/off.Each press of this button should turn the LED on/off.Each press of one of these butt
24、ons should turn the corresponding LED on/off.Each press of this button should turn the LED on/off.Each press should turn the LED on/off.Each press should turn the LED on/off.Each press of this button should turn the LED on/off.Each press of this button should turn the LED on/off.Each press of this b
25、utton should turn the LED on/off.1-5Turn this VR and confirm that data varies between 0 and 255. Turning clockwise should increase the value.This VR also controls the LCD contrast. It is Normal at the center. Turning the VR clockwise should increase contrast and counter-clockwise should decrease it.