1、 Part No. 12460 Rev. 0 INSTRUCTION MANUAL For CIRCUIT BREAKER TEST SETS MODEL CB-8100 SERIES SERIAL NO. It is essential that this instruction book be read thoroughly before putting the equipment in service. RadioFans.CN 收音机爱 好者资料库 Part No. 12460 Rev. 0 IMPORTANT The information and data contained wi
2、thin this instruction manual are proprietary with MULTI- AMP Corporation. The equipment described herein may be protected by one or more U.S. letters patent. MULTI-AMP specifically reserves to itself all rights to such proprietary information as well as all rights under any such patent, none of whic
3、h is waived by the submission of this instruction manual to anyone. The recipient, if a Government agency, acknowledges that this instruction book and the equipment described were procured with Limited Rights to technical data as described in ASPR 9-203 (b). Copyright MULTI-AMP Corporation, 1980, 19
4、82, 1986, 1987 RadioFans.CN 收音机爱 好者资料库 Part No. 12460 Rev. 0 i TABLE OF CONTENTS Section Page I. Introduction A. General Description . Bulletin B. Specifications . Bulletin II. Description of Controls and Instrumentation A. General Description . 1 B. Controls and Instrumentation . 1 C. Ammeter Circu
5、it . 4 III. Input and Output Circuits A. Input . 5 1. Input Voltage . 5 2. Input Leads . 5 3. Grounding. 5 4. Safety Precautions . 6 B. Output 1. Selection of Output Connections . 7 2. Output Connections . 8 3. Duty Ratings and Overload Capabilities . 8 IV. Test Procedures A. Testing Motor Overload
6、Relays . 11 B. Testing of Low Voltage Circuit Breakers . 14 V. Maintenance of Protective Apparatus A. Maintenance of Motor Overload Relays . 18 B. Maintenance of Molded Case Circuit Breakers . 21 C. Maintenance of Low Voltage Circuit Breakers . 22 D. Suggested Test Forms . 24 E. Service Data . 25 VI
7、. Schematic Drawing RadioFans.CN 收音机爱 好者资料库 Part No. 12460 Rev. 0 1 DESCRIPTION of CONTROLS and INSTRUMENTATION General Description: Multi-Amp Circuit Breaker Test Sets are portable high current units designed for testing and adjusting low voltage circuit breakers and other current actuated devices.
8、 The units incorporate a variable high current ac output, solid state output initiating and timer initiation circuitry, electronic digital timer, multi-range memory ammeter and circuitry to monitor contact closure or opening. The units are self protected against overloads and short circuits. Control
9、s that is, 30 minutes ON followed by 30 minutes OFF. In other words, the equipment can supply rated output current for a maximum period of 30 minutes ON provided a 30 minute cooling OFF period follows. This is a satisfactory basis of rating for testing of circuit breakers and primary injection testi
10、ng of relay and current transformers. When Multi-Amp equipment is being used for heat runs on cables, busbars, terminations, etc., the 30 minute ON time will be exceeded. In such cases the output current should be limited to 70 percent of the rated output current and may be continued for an indefini
11、te time. In addition to the continuous duty rating defined above, all units have considerable short- time overload capability. Duration of the overload is governed by thermal considerations within the test set. The maximum current available is determined essentially by the Part No. 12460 Rev. 0 12 i
12、mpedance of the load. The duty cycles of the CB-8100 series is as follows: Part No. 12460 Rev. 0 13 DUTY CYCLES ON CB-8100 SERIES 60 HZ CIRCUIT BREAKER TEST SETS (Current Rating Through Circuit Breaker) CB-8115 CURRENT TIME ON TIME OFF 2,240 A 3,200 A 4,500 A 7,500 A 15,000 A Continuous 30 min. 15 m
13、in. 1 min. 3 sec. N/A 30 min. 45 min. 12 min. 3 min. CB-8130 CURRENT TIME ON TIME OFF 3,000 A 4,500 A 6,000 A 15,000 A 30,000 A Continuous 30 min. 15 min. 2 min. 5 sec. N/A 30 min. 45 min. 60 min. 12 min. CB-8160 CURRENT TIME ON TIME OFF 4,500 A 6,250 A 10,000 A 30,000 A 60,000 A Continuous 30 min.
14、15 min. 2 min. 5 sec. N/A 30 min. 45 min. 60 min. 12 min. THERMAL SET POINTS* Normal: 72 to 80F Warning: 150 to 180F Shutdown: 220 to 248F *Temperature measured at output stabs adapter plates. Part No. 12460 Rev. 0 14 DUTY CYCLES ON CB-8100 SERIES 50 Hz CIRCUIT BREAKER TEST SETS (Current Rating Thro
15、ugh Circuit Breaker) CB-8116/8117 CURRENT TIME ON TIME OFF 2,223 A 3,162 A 4,446 A 7,410 A 14,820 A Continuous 30 min. 15 min. 1 min. 3 sec. N/A 30 min. 45 min. 12 min. 3 min. CB-8131/8132 CURRENT TIME ON TIME OFF 2,964 A 4,446 A 5,928 A 14,820 A 29,640 A Continuous 30 min. 15 min. 2 min. 5 sec. N/A
16、 30 min. 45 min. 60 min. 12 min. CB-8161/8162 CURRENT TIME ON TIME OFF 4,446 A 6,175 A 9,880 A 29,640 A 59,280 A Continuous 30 min. 15 min. 2 min. 5 sec. N/A 30 min. 45 min. 60 min. 12 min. THERMAL SET POINTS* Normal: 22.2 to 26.7C Warning: 65.6 to 82.2C Shutdown: 104.4 to 120C *Temperature measured
17、 at output stab adapter plates. Part No. 12460 Rev. 0 15 TEST PROCEDURES FOR TESTING OF MOTOR OVERLOAD RELAYS Always refer to the manufacturers literature applicable to the particular overload relay before testing. The test operator should be familiar with the operating characteristics of the relay,
18、 the tolerances applicable to the operating characteristics and any means of adjusting the relay. The test usually performed on these devices is to verify the time delay characteristics of the relay when subjected to an overload. One test point is usually suggested to establish whether the relay is
19、operating correctly and within the band of the time-current curve for the relay. The suggested test current is three times (3x) the normal current rating of thermal overload relays or three times (3x) the pick-up current (setting) of magnetic overload relays. It is, of course, easiest to make the co
20、nnections and perform the tests on the relays if they are removed from the starter. However, it is not necessary to remove the relay as long as the power circuit is de-energized and the test leads can be connected to the device. The high current leads from the test set to the relay under test should
21、 be kept as short as possible and should be twisted to minimize losses caused by inductive reactance. Run the test and note the time required for the overload relay to trip. If the tripping time exceeds the desired value, or if the relay does not trip at all, the relay may not be protecting the moto
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle CB-8100-Series_UG 电路图 CB 8100 Series_UG
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf