FLUKE 803D_Army 电路图.pdf
《FLUKE 803D_Army 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 803D_Army 电路图.pdf(58页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 9-4935-282-34 DEPARTMENT OF THE ARMY TECHNICAL MANUAL FIELD MAINTENANCE MANUAL VOLTMETER, ELECTRONIC JOHN FLUKE MODEL 803D FSN 6625-072-4303 This copy is a reprint which includes current pages from Change 1. HEADQUARTERS, DEPARTMENT OF THE ARMY MARCH 1964 RadioFans.CN 收音机爱 好者资料库 TM 9-4935-282-34
2、C1 WARNING RADIATION HAZARD This equipment contains the following radioactive items: NomenclatureFSNIsotopeAmount (Microcuries) OA2 Vacuum tube5960-503-4880UO 20.10uc OA2 Vacuum tube5960-503-4880Ni630.50uc OA2 Vacuum tube5960-503-4880Co600.20uc OG3-2 Vacuum tube5960-912-7630UnknownUnknown Refer to T
3、M 3-261, TM 38-250, and TB 750-237 for information relative to shipping, storage, handling, and disposal of radioactive material. FIRST AID FOR RADIOACTIVE CONTACT The following first aid procedure for wounds caused by anything coated with a radioactive material represents the only reasonable first
4、aid treatment which would possibly be available. a.Stimulation of mild bleeding by normal pressure about the wound and by use of suction cups. WARNING: Do no suck the wound by mouth. The wound must be washed with soap and flushed with plenty of clear water. b.If the wound is of the puncture type, or
5、 the opening is quite small, an incision should be made to promote free bleeding and to facilitate cleaning and flushing of the wound. c.Evacuate patient to a medical facility where monitoring of the wound can be accomplished. All such wounds should be examined by a medical officer. d.For wounds inv
6、olving the extremities, pending medical attention, place a lightly constricting band (tourniquet) 2 to 4 inches closer to the heart than the site of the wound. The band should be tight enough to halt the flow of blood in superficial blood vessels but not tight enough to stop the pulse arterial flow)
7、. CLEANING SURFACES ON WHICH TUBES HAVE BEEN BROKEN Wet Method. Put on rubber or plastic gloves. Pick up large fragments with forceps; then, using a wet cloth, wipe across the area. Make one wipe at a time and fold cloth in half, using the clean side for wiping each time. When cloth becomes too smal
8、l, discard and start again with a clean piece of cloth. Care must be taken not to rub the radioactive particles into the surface being cleaned by using a back and forth motion. All debris and cloths used for cleaning should be sealed in a container such as a plastic bag, heavy waxed paper, ice cream
9、 carton, or glass jar for disposal. RadioFans.CN 收音机爱 好者资料库 TM 9-4935-282-34 ERRATA AND ADDENDUM Model 803D/AC This manual was intended for use with the 803D AC/DC Differential Voltmeters. The 803D/AC, however, is very nearly electrical identical to the 803D/AG. Physical and electrical differences i
10、nclude: 1.The Model 803D/AC is mounted in a combination instrument-transit case made of aluminum. This case meets all environmental requirements of MIL-T-945A. 2.The Model 803D/AC does not have recorder output provisions. 3.Line power input for the Model 803D/AC is by way of an MS3102A-10SL-3P conne
11、ctor on the front panel. A power input cable with a mating connector (MS3102A-10SL-3S), a three-prong polarized connector, and a three- prong to two-prong grounded adapter is furnished. Storage space for the input cable is provided in the lid o the combination case. 4.One set of universal test leads
12、 (part no. 699 - Hermin H. Smith, Inc., Brooklyn, New York) is provided with the Model 803D/AC. These test leads are stored in the lid with the power input cable. 5.Heater resistors R6 and R7 are not used in the Model 803D/AC because the instrument is completely enclosed by the transit case. However
13、, a Zener oven containing a heater and a thermostat must be used to maintain the Zener diode reference element at a constant temperature. The Zener diode plugs into the inside of the Zener oven and the Zener oven plugs into a chassis mounted tube socket. 6.The line fuse is located on the front panel
14、 of the 803D/AC. 7.The 803D/AC uses a specially enclosed transformer to prevent leakage at higher operating temperatures. 8.The converter output diodes of the 803D/AC are selected for low leakage to provide for proper operation at the higher operating temperatures reached within the transit case. (a
15、) RadioFans.CN 收音机爱 好者资料库 TM 9-4935-282-34 To create a parts list for the 803D/AC, change the 803D list of replaceable parts as follows: Delete: Front Panel Assembly*803D/AG-435 Converter/AC Range Switch Assembly*803D-438 CR501, 502Diode, silicon, 60 maRE22 J4, J5Binding post, redX2231 Binding post
16、insulator, dual, black*801B-830 R1Resistor, variable wirewound, 10K, +10%, 2WP10KA R6, R7Resistor, wirewound, 6K +5%, 5WR6KW T1Transformer, power*803C-651 Line cord, 3 wireX27H Rubber footX224 Case Assembly (cabinet model) *803B-271 Handle, flexible black vinyl, 5-1/2 (cabinet model)407-101 Add: Fro
17、nt Panel Assembly*803D/AC-403 Converter/AC Range Switch Assembly*803D/AC-404 CR501, 502Diode, silicon, 60 ma, 40 PIV (selected RE22) *803D/AC-402 T1Transformer, power*821A-651 Case, instrument-transit*803D/AC-271 Connector (mates with line cord) M3102A-10SL-3P Line cord*803D/AC-401 Test lead setX232
18、2 Tube socket (for Zener oven) X52 Zener diode oven (includes heater and thermostat)X2259 (b) TM 9-4935-282-34 To create a schematic diagram for the 803D/AC, change the 803D schematic as follows: c TM 9-4935-282-34 803D Material in this manual is used by permission of John Fluke Manufacturing Compan
19、y, Inc. TABLE OF CONTENTS SectionTitlePage IINTRODUCTION AND SPECIFICATIONS1-1 1-1.Introduction.1-1 1-2.Damage in Shipment .1-1 1-3.Specifications.1-1 IIOPERATING INSTRUCTIONS2-1 2-1.Controls, Terminals, and Indicators .2-1 2-2.Zeroing Instructions .2-3 2-3.Preliminary Operation.2-3 2-4.Operation as
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FLUKE 803D_Army 电路图 803 D_Army
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf