F74 电路图.pdf
《F74 电路图.pdf》由会员分享,可在线阅读,更多相关《F74 电路图.pdf(93页珍藏版)》请在收音机爱好者资料库上搜索。
1、- . - ,l JL= -10; 30 )Z-r Gc Instruction MANUAL Model No. _ Serial No. _ _ SERIES7D FUNCTION GENERATOR MODELS F74/F77 ,-) EC INTERSTATE ELECTRONICS CORPORATION A SUbSldl.Y Of A-T-O Inc. -.;.-.- Department 7000 707 EAST VERMONT AVENUE, ANAHEIM. CALIFORNIA 92803 (714) 772-2811 PART NO. PO0338099-4 (F7
2、4-F77) CD COPYRIGHT 1975 PRINTED 1975 DIGITAL Y REMASTERED OUT OF PRINT TEST EQUIPMENT MANUAL SCANS By ArtekM anuals (fonnerly known as ArtekMedia and A) 6102 LIBERTY AVE. TEMPLE TERRACE, FL 33617 High resolution scans of obsolete technical manuals REMOVAL OF THIS DISCLAIMER IS IN VIOLATION ARTEKMAN
3、UALS DERIVATIVE COPYRIGHTS. DUPLICATION OR MODIFCATION OF THIS DIGITAL DOCUMENT WITHOUT PRIOR CONSENT IS NOT PERMITTED If your looking for a quality scanned technical manual in PDF format please visit our WEB site at www.ArtekM or drop us an email at ManualsArtekM If you dont see the manual you need
4、 on the list drop us a line anyway we may still be able to point you to other sources. If you have an existing manual you would like scanned please write for details. This can often be done very reasonably in consideration for adding your manual to our library. Typically the scans in our manuals are
5、 done as follows; 1) Typed text pages are typically scanned in black and white at 300 dpi. 2) Photo pages are typically scanned in gray scale mode at 450 dpi 3) Schematic diagram pages are typically scanned in black and white at 600 dpi or Gray-scale 450dpi depending on the characteristics. 4) All m
6、anuals are text searchable and all manuals are fully bookmarked All data is guaranteed for life (yours or mine . which ever is shorter). If for ANY REASON your file becomes corrupted, deleted or lost, ArtekManuals will replace the file for the price of shipping, or free via FTP download. Thanks DC H
7、enderson Founder and CEO Artek Media ArtekManuals Outsource-Options THIS PAGE INTENTIONALLY BLANK. INSERTED HERE FOR DOCUMENT PAGE NUMBER CONTINUITY SCANS BY ARTEK-MANUALS ArtekManuals 2015 ii WARRANTY Interstate Electronics Corporation warrants its function generators against defects in material an
8、d workmanship for a period of one year from date of shipment. We will repair or replace defective products during the warranty period provided that such defect developed under normal and proper use and that transportation costs are paid by the purchaser. We are not liable for consequential damages n
9、or is any other warranty expressed or implied. RECEIVING AND INSPECTION Immediately upon receipt of the instrument, inspect the exterior of the shipping container for physical damage and notify carrier if such damage is visible. After carefully removing all packing materials, inspect the instrument
10、to ensure that it is free of mars and blemishes. CLAIM FOR DAMAGED SHIPMENT If damage has occurred, a claim should be made with the carrier. The claim agent should receive a complete report of damage and a copy of the report should be sent to IEC. After receiving this report, IEC will advise you of
11、the disposition of the instrument and arrange for its repair or replacement. POWER This instrument operates from a-c power only, either 115 or 230 vac, 50 to 400 Hz. A slide switch at the rear of the equipment readily selects the desired power line voltage . . : CAUTION : I I . Operation at the wron
12、g power line voltage switch setting may damage the instrument. PERFORMANCE TESTS Electrical performance tests should be concluded as soon as possible. See paragraph 4-2, Section 4. ) ArtekManuals 2015 Paragraph 1-1 1-2 1-3 1-4 1-5 1-6 1-7 2-1 2-2 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-9 3-10 3-11 CONTENT
13、S Section 1. SPECIFICATIONS AND INSTALLATION Introduction. . . . . . . . Description . . . . . . . . Performance Characteristics Receiving and Inspection Installation . . . . . Power Requirements . Repackaging . . . . Section 2. OPERATING INSTRUCTIONS Introduction. . . . Operating Controls. Introduc
14、tion. Power Supply Main Loop . Section 3. CIRCUIT DESCRIPTION Follow Amplifier /Low-Frequency Integrator Start/Stop . . . . . . . . . . Sine Shaper. . . . . . . . . . Logic/Rectangular Wave Shaper Inverter /Offset/Output Amplifier Sweep Generator . . . Log Sweep Converter Pulse-Width Generator. 1-1
15、1-1 1-1 1-5 1-5 1-5 1-6 2-1 2-1 3-1 3-1 3-1 3-3 3-4 3-4 3-4 3-4 3-5 3-6 3-6 iii ArtekManuals 2015 Paragraph v 4-1 4-2 5-1 5-2 6-1 6-2 Section 4. CALIBRATION AND PERFORMANCE Introduction Test Points and Adjustments Introduction Timing Diagrams Introduction. . . . Parts List Tables . Section 5. MAINTE
16、NANCE Section 6. PARTS LIST 4-1 4-1 5-1 5-1 6-1 6-1 ArtekManuals 2015 Figure 2-1 2-2 ILLUSTRATIONS Section 2. OPERATING INSTRUCTIONS Controls and Indicators . . . . Output/Sync Out Phase Relationships Section 3. CIRCUIT DESCRIPTION 3-1 20MHz Sweep Function Generator (F74-F77 Models) -Simplified 4-1
17、4-2 4-3 5-1 5-2 5-3 5-4 5-5 5-6 5-7 5-8 Block Diagram . . . . . . . . . . . . . . . Section 4. CALIBRATION AND PERFORMANCE Adjustment Location Diagram (F44/F77 Models, A-1 Card) Test Point Location Diagram (F44/F77 Models, A-1 Card) Test Point Location Diagram (Solder Side) . Section 5. MAINTENANCE
18、A2 Board (Series 70 Models) -Disassembly Diagram Attenuator Switch Assembly . . . . . . . . . . Sweep Time Switch (F44/F77 Models) . . . . . Waveform Switch (F44/F77 Models) -Wiring Diagram Front Panel Components (F74/F77 Models) -Location Diagram Rear Panel Components (F74/F77 Models) -Location Dia
19、gram. Timing Diagram -Triggered and Gated Modes . . . . . Timing Diagram -Sweep Trigger and Sweep nonsymmetrical sine, square and triangle waveforms to 1 MHz. Ten decade ranges, up to 1000:1 continuous vernier adjustment within any X2 dial range, 500: 1 on any Xl dial range. Independent, free-runnin
20、g, sweep-ramp generator provides sweep times from 1000 seconds to 10 J.lS (exclusive of re- trace) in seven decade ranges with 100:1 continuous vernier adjustment within any range. Dial Accuracy (With dial scale switch at SYMMETRICAL Xl or X2): 0.00002 Hz to 20 Hz: 2% of full scale 1 % of setting 20
21、 Hz to 200 kHz: 1% of full scale 1 % of setting 200 kHz to 2 MHz: 2% of full scale 1 % of setting 2 MHz to 20 MHz: 3% of full scale 2% of setting Time Symmetry (with dial scale switch in Xl or X2): 99%,. to 20 Hz; 99. 5%, 20 Hz to 100 kHz; 98%, 100 kHz to 2 MHz AMPLITUDE Output Levels -Main Amplifie
22、r: Maxi- mum output of sine, triangle, square and pulse waveforms is 30V p-p (bipolar) into open circuit or high-impedance loads (e. g., MOS), 15V p-p into 50-ohm load. Source impedance is 50 ohms. Minimum output is 1. 5 mV p-p. Sweep waveforms exited through main amplifier are uni- polar. Combined
23、signal plus offset must lie in region between 15V open circuit or7. 5V into 50-ohm load. Short-circuit- proof. 200 milliamps maximum current output on any waveform. Attenuator: Precision aUenuator provides three 20-dB (10:1 in voltage) steps plus continuously variable 0-20 dB vernier; permits 80-dB
24、output adjustment to 1. 5 mV p-p minimum. WAVEFORM CHARACTERISTICS Frequency Response (Sine, triangle, square wave and pulse): Better than 0.1 dB to 100 kHz; 0.25 dB, 100 kHz to 2 MHz; 2dB, 2 MHz to 20 MHz. Square wave and Pulse (50-ohm termin- ation): Standard pulse width adjustable ArtekManuals 20
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- F74 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf