Rohde & schwartzSMDU_249.3011_Vol.1_Manual 电路图.pdf
《Rohde & schwartzSMDU_249.3011_Vol.1_Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《Rohde & schwartzSMDU_249.3011_Vol.1_Manual 电路图.pdf(154页珍藏版)》请在收音机爱好者资料库上搜索。
1、( DEL Fi5. 2-4 Fi. 4-1 Fi5. 4-2 Fi5. 4-;L Fiez.4-4 Fi5. 4-5 Fi. 4-6 Fi. 4-7 Fi. 1-1 Fi. 1-2 Fi5. 2-1 Fi-1 Fis;.2-2 to5-4 Fi. 5-5 to 5-13 Table 2-1 Removing and Opening the Subassemblies 148 CormterY7 148 OscillatorYl .149 Range Switch Yl0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
2、 .AmplifierY2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 MixerOscillator Y6150 RF Attenuator Y4 Power Supply Y9 .150 151 151 . Modulation Unit Y8. 1.05-GHz Frequency Range-Extension SMDU-B3 and 1.05-GHz Frequency Doubler SMDU-B5 152 Doubler Y301.152 152 153 153 Bandpass Filters 0.5
3、- 1 GHz Y302 and Final Stage Y303 Incorporating Options into the SMDU Synchronizer SMDU-Bl. 1.05-GHz Frequency Range Extension SMDU-B3 and 1.05-GHz Frequency Doubler SMDU-B5 153 1-GHz Frequency Meter SMDU-B4 154 Modification of Synchronizer SMDU-Bl 154 Real power with mismatch23 Equivalent circuit d
4、iagram of a noise voltage source 24 Control circuits of amplifier Y2 74 Block diagram of AF processing circuit 86 Distortion meter with level control 90 Block diagram of control logic in modulation unit 92 SIMPIBX. mode. 95 DUPIBX. mode96 Relaymode98 Block diagram including all options Radiotelephon
5、e test assembly Controls RF levels Logic levels Inside views Contact occupation of socket BCD OUTPUTS/RECORDER Appendix R 35169 -9 ._:t ;,_. i ,. ,(i: 1,:-.-11 -.-. 2.Preparationfor Use and OperatingInstructions The valuesmentionedin thissectionare not guaranteed;onlythe specifica- tions givenin 1.3
6、 are binding. ( 2.1Legend for Fig. 2-1 The reference rrumbers to2refer to the control elements of the Synchro- nizer SMDU-Bl, which can be incorporated subsequently. FunctionRef.No.IEngraving 1 I 392-525784-1050 286-395572-790 196-290510-580 118-198 85-119 63.5-88 49-64.5 I I 0.14-50 2 Pushbuttons f
7、or selecting the frequency range. The red engraving of the upper three ranges (510 to 1050) is applicable if the 1.05-GHz Frequency Range Extension SMDU-B3 or the 1.05-GHz Frequency Doubler SMDU-B5 is incorporated and button 2 depressed.- Button for frequency doubling. Pressing this button doubles t
8、he upper three frequency ranges if the 1.05-GHz Frequency RangeEx.- tension SMDU-B3 or the 1.05-GHz Frequency Doubler SMDU-B5 is incorporated. Then the red engravings apply. Digital frequency readout. Operating mode and frequency range are selected by means of buttons11 Internal RF or AF or ex- tern
9、al frequencies applied to sockets45 , 46 ,47can be measured. Button10per- mits the resolution to be multipliedby ten. 4SYNCHRONButton for cutting in synchronization (no synchronization possible, when pushbutton 11EXT. 20 - 525 MHz is depressed). With synchronization on, lamp.2lights up. The state of
10、 synchronization is indicated on meter6 Pilot lamp lighting up with synchronization mode. 6CONTROL VOLT.Meter for indicating the state of synchroni- zation. 1 CH. SPACING 12.5/20/25/50/100/ 150 kHz Switch for selecting the spacing of the locked frequencies for synchronization. With synchronization m
11、ode (buttonand one of buttons 11, except for EXT. 20 - 525 MHz, pressed) and when turning the fine-tuning control 50, the signal generator frequency varies according to the selected spacing of the locked frequencies. R 35169 - 11 Ref.No.EngravingFunction () 8FINE IDNINGButton for cutting in fine tun
12、ing. Fine tuning of the synchronized signal generator frequency is made with rotary switch.2 . FREQ. FINEincoaxial rotary control for tuning of the synchronized signal-generator frequency; !button8must be depressed. Outer knob: 1 rotation=about 106of selected frequency spacing nner knob: 1 rotation=
13、about 0.1% of selected frequency spacing 10RESOL. xlOButton for multiplying the resolution of frequency readout2byten. 11 0.5 - 1 GHz 20 -525 MHzEXT. 15 Hz - 30 MHz :INT. Buttons for selecting the operating mode and the frequency range of frequency read- out2.Internal (INT.) or external (EXT.) frequ
14、encies canbemeasured, external sig- nals being fed into sockets,46or 47 Frequencies from 525 MHz to1GHz can be measured only if the 1-GHz Frequency MeterSMDU-B4is incorporated. 12MOD. INT. EXT. AM Blttons for cutting in the amplitude modu- lation and for selecting internal or extern- al AM. With ext
15、ernal AM, the signal is fed into socket51 With button23AM de- pressed, meter15indicates the modula- tion depth (adjusted with35 ) 13IPREEMPH. 6dB/OKT. 14IMOD. INT.FM EXT. Buttons for cutting in a preemphasis of 6dB/octave with FM. Blttons for cutting in the frequency modu- lation and for selecting i
16、nternal or ex- ternal FM. With external FM, the signal is fed into socket With button23FM depressed, the frequency deviation is indi- cated on meter1.2(adjustment with17 ). Meter for indicating the modulation depth, the frequency deviation, the phase devia- tion, the voltage at modulation-generator
17、output41 , the voltage at AF voltmeter in- put44-,-thedistortion or the SINAD ratio. The type of indication is selectedbymeans of buttons23 , the range of indication with switch22 lYpe and range of indica- tion are displayed on16 16Illuminated display of type of indication selected with buttons23(kH
18、z, rad,%,mV) and of indicating range selected with22 R 35169 - 12 Ref .No.EngravingFunction ( 18 20 10 100 kHz MOD.GENERATOR FIXEDVAR. 6 3 2.7 1 0.4 0.3 kHz FREQ. 10-30 3-10 1-3 0.3-1 0.1-0.3 0.03-0.1 kHz Push-pull rotary knob for adjusting a fre- quency deviation up to 10 kHz (in) or up to 100 kHz
19、(out). The frequency modulation is selected with If button23FM is de- pressed, the frequency deviation is indicated on meter1.2 The button permits adjustment of the phase deviation if13is pressed. Button for selecting the fixed frequencies set with19(released) or the ranges set with19Pressed) and tu
20、nable with.! . Buttons for selecting the fixed frequencies (left column) or the frequency ranges (right column) of the modulation generator depend- ing on the position of button18 Fine tuning of the modulation frequency is made with21 ,the frequency being indicated on roor-L. Scale for indicating th
21、e frequency of the internal modulation generator if18is pressed. The frequency rangeisselected with19 ,fine tuning of the frequency is made with21 With button AF INT.11 pressed, the digital frequency readoutL indicates the accurate modulation frequency if one of buttonsMOD.12or14is pressed. .C:- 21
22、22RANGE AUTO STOP MAN. Rotary knob for adjusting the frequency of the modulation generator if13is pressed. Ihefrequency range is selected with buttons 19and the frequency read on20 With button AF INT.Qpressed, the frequency of the modulation generator is indicated on the digital readoutL .The modula
23、tion ge- nerator is operative only if at least one of buttonsMOD.oris pressed. Range selector for meter15 .In the upper position the indicating range is selected automatically, in mid-position the momentary range is preserved and each time when setting the switch to the lower position switchover to
24、the next range is effected. The indicating range is displayed on1. R35169 - 13 Ref.No.EngravingFunction (. INDICATION FM fM 6dB/OKT. AM MOD. GEN. AFVOLIM. Buttons for selecting the type of indication of meter15 lhemeasuring unit (kHz, rad, %.mV) is displayed on16 24DEV.METER ON Button for switching
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rohde schwartz SMDU_249.3011_Vol.1_Manual 电路图 SMDU_249 3011 _Vol _Manual
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


