1、 HP Archive This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! On-line curator: Georg zur Horst-Meyer RadioFans.CN 收音机爱 好者资料库 le OPERATORS GUIDE 1744A OSCILLOSCOPE HEWLETT PACKARD RadioFans.CN 收音机爱 好者资料库 SAFETY SUMMARY The following general safet
2、y precautions must be observed during operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Hewlett-Packard Company assumes no liability for the c
3、ustomers failure to comply with these requirements. GROUND THE INSTRUMENT. To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. The instrument is equipped with a three-conductor ac power cable. The power cable must either be plugged into an approved
4、 three-contact outlet or used with a three-contact to two-contact adapter with the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable meet International Electrotechnical Commission (IEC) safety standa
5、rds. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard. DO NOT REMOVE INSTRUMENT COVERS. Operating personnel must not remove instrume
6、nt covers. Component replacement and internal adjustments must be made by qualified maintenance personnel.Service instructions for this instrument are provided in a separate Operating and Service Manual. DANGEROUS PROCEDURE WARNINGS. Warnings such as the example below, precede potentially dangerous
7、procedures throughout this manual! Instructions contained in the warnings must be followed. WARNING Dangerous voltages, capable of causing death, are present in this instrument. Use extreme caution when handling, installing or operating. RadioFans.CN 收音机爱 好者资料库 ii OPERATORS GUIDE MODEL 1744A OSCILLO
8、SCOPE COPYRIGHT HEWLETT-PACKARD COMPANY/COLORADO SPRINGS DIVISION 1978 1900 GARDEN OF THE GODS ROAD, COLORADO SPRINGS, COLORADO, U.S.A. ALL RIGHTS RESERVED Operators Guide Part Number 01744-90902 Microfiche Part Number 01744-90802 PRINTED: AUGUST 1978 Table of Contents Model 1744A TABLE OF CONTENTS
9、Page GeneralInformation . 1 Description. 1 AccessoriesFurnished . 8 Accessories and Options Available . 8 Preparationfor Use . 8 PowerCord . 8 PowerRequirements . 9 Controlsand Connectors . 10 Turn-on Procedure . 18 Checking Instrument Performance . TraceAlignment . Astigmatismand Focus . ProbeCompe
10、nsation . VerticalAccuracy Check. SweepTime Accuracy . TriggerSelection Table . ObtainingBasic Displays . NormalSweep Display . MagnifiedSweep Display . DelayedSweep Display . MixedSweep Display . X-Y Display . Variable Persistance - Storage Operation. AutoErase . AutoStore Mode. ContinuousScan . Pa
11、ge EliminatingFlicker . 29 Storinga Trace . 30 Display Brightness Control . 30 MeasurementTechniques . 31 Introduction. 31 VoltageMeasurements . 31 Absolute Voltage Measurements . 32 Peak-to-peak Voltage Measurements . 33 Average Voltage Measurements . 34 Amplitude Comparison Measurements . 35 Metho
12、d1 . 35 Method2 . 36 CommonMode Rej ection . 36 Time-interval Measurements . 38 PeriodMeasurements . 38 Repetition Rate or Frequency Measurements . 38 Transition Time Measurements . 39 DelayedSweep . 40 Measuring Phase Difference by Time Delay . 43 Avs B Phase Measurements . 45 Triggering. 46 Trigge
13、rView . 46 Eliminating Multiple Triggering an ComplexWaveforms . 47 Measuring CRT Writing Speed . 48 19 19 20 20 21 21 21 21 21 23 24 25 25 26 26 26 28 11 Model 1744A Operators Guide MODEL 1744A OPERATORS GUIDE OPERATING INSTRUCTIONS GENERAL INFORMATION. This Operators Guide will acquaint you with t
14、he Model 1744A features, capabilities, accessories, power require- ments, and controls. To aid in operating the oscillo- scope, initial turn-on instructions, calibration proce- dures, and a performance check are provided. Detailed explanations in the Applications Section show how you can use varied
15、capabilities of the 1744A to best ad- vantage in a variety of electrical measurements. Speci- fiications and general characteristics for the 1744A are listed in tables 1 and 2. Service information is available in a separate service manual. DESCRIPTION. The Hewlett-Packard Model 1744A is a dual-chann
16、el, 100-MHz, delayed-sweep variable persistence storage oscilloscope designed for single-shot transients and low duty cycle waveform analysis in the bench or field environment. The writing speed specification of 1800 cm/s permits full screen capture of transients at the maximum slew rate of the vert
17、ical amplifier system. The dual-channel dc to 100 MHz vertical deflection system has 12 calibrated deflection factors from 5 mV/div to 20 V/div. A maximum sensitivity of 1 mV/div to 30 MHz is provided an both channels by means of a 5X vertical magnification feature. Selectable input impedance of 50
18、ohms or 1 megohm permits selection of that impedance which best meets measurement requirements. The hori- zontal deflection system has calibrated sweep rates from 2 s/div to 0.05 s/div and delayed sweep rates from 20 ms/div to 0.05 gs/div. A 10X magnifier expands all sweeps by a factor of 10 and ext
19、ends the fastest sweep to 5 ns/div. In alternate or chop modes, a trigger-view control will display three signals: the channel A signal, the channel B signal, and the trigger signal. This allows you to correlate time between the trigger signal and the channel A and channel B signals. In trigger-view
20、 operation, center screen represents the trigger threshold point, allowing you to see the triggering level location. With the A VS B control, an X-Y mode of operation is possible. The channel A input (Y-axis) is plotted versus the channel B input (X-axis). A trigger-view control provides capability
21、for observing the channel A signal, channel B signal, and an external Operators Guide Model 1744A Table 1. Specifications VERTICAL AMPLIFIERS (2) Bandwidth and Rise Time at all deflection factors from 0C to +55C. BANDWIDTH: 3 dB down from 6 div reference signal. DC-Coupled: dc to 100 MHz in both 50f
22、1 and 1 Mn input modes. AC-Coupled: approx 10 Hz to 100 MHz; 1 Hz with 10:1 divider probes. BANDWIDTH LIMIT: limits upper bandwidth to approx 20 MHz. RISE TIME: 3.5 ns, measured from 10% to 90% points of a 5 div input step. DEFLECTION FACTOR Ranges: 5 mV/div to 20 V/div (12 calibrated positions) in