HP-412A-AR-Manual 电路图.pdf
《HP-412A-AR-Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-412A-AR-Manual 电路图.pdf(40页珍藏版)》请在收音机爱好者资料库上搜索。
1、I . : HP Archive . . This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! . . On-line curator: Tony Gerbic RadioFans.CN 收音机爱 好者资料库 I i i (r, , a i f OPERATING A N D SERVICE M A N U A L (HP PART NO. 00412-90003) MODEL 412A/AR DC VACUUM TUSE VOLTMETE
2、R SERIALS PREFIXED: 301-, 3160, 424-, 649- Copyright Hewlett-Packard Company 1961 P. 0. Box 301, Loveland, Colorado, 80537 U. S.A. 1 i O O T 2 9 - 5 Printod: NOV 1968 I RadioFans.CN 收音机爱 好者资料库 0 Model 4 12A h TABLE OF CONTENTS Section Page I GENERAL INFORMATION . 1-1 1.1 . Introduction . 1-1 1.7 . S
3、pecifications . I -I 1.Y . instrument and Manual Identification . 1-1 . Section I . ? Page 11 INSTALLATlON . 2-1 2.1 . Introduction . 2-1 2.3 . Initial inspection . 2-1 2.5 . Power Requirements . 2-1 2.7 . Grounding Requirements . 2-1 2.10 . lnstallatiori . 2-1 2.13 . Repackaging for Shipment . 2-1
4、i i 1 Section Page I11 OPERATING INSTRUCTIONS . 3-1 3.1 . Introduction . 3-1 3 . 3 . Low-Level Electrical Phenomena . 3-1 3.7 . Turn 1 volt at full scale; maximum current, 1 mA. (Full scale corresponds to 1 .O on upper scale.) Output Impedance: Less than 2 ohms at dc Noise: Less than 5 mV RMS on any
5、 range Drift: negligible GENERAL Isolation Resistance: At least 100 megohms shunted by 0 . 1 F between common terminal and case (power line) ground Common Mode Rejection: May be operated up to 500 Vdc or 130 Vac from ground Power: 115/230 V f10%, 5040 Hz, 35 W Dimensions: Cabinet Mount: 11-1/2 in. h
6、igh, 7-1/2 in. wide, 10 in. deep Rack Mount: 001 29-5 Model 4 12A 1-1. INTRODUCTION. Section I SECTION I GENERAL INFORMATION 1-2. The Hewlett-Packard Model 412A/AR DC Vacuum Tube Voltmeter is a multifunction instrument which measures the entire range of dc voltages, current, and resistance normally
7、encountered in electronic equipment. 1-3. The Model 412AIAR measures dc voltage from 1.0 mV full scale to IO00 V full scale in thirteen ranges arranged in a 1,3, 10 sequence. Voltmeter accuracy is 1% of full scale. The input circuit is isolated from the case and from power line ground. 14. The Model
8、 412AlAR measures positive or negative dc current from 1.OpA full scale to 1.0 A full scale with an accuracy of 2% of full scale. Current ranges are also in a 1, 3, 10 sequence. 1-5. Resistance measurement capability of the Model 412AIAR is from 1.0 ohm center scale to I 0 0 megohms center scale in
9、nine decade rangcs. Resistaiicc nieasureiiieiit accuracy is 5% between .3 and 3 on the resistance scale. 16. The Model 412AIAR has a dc aiiiylifier output voltage proportional to the input. Ainplificr giiiil is froiii -1000 to t1000, depending on range selected. 1-7. SPEC1 FlCATlO NS. 1-8. Complete
10、specifications for the dip- Modcl41 2AIAR are listed in Table 1-1. 1-9. INSTRUMENT AND MANUAL IDENTIFICATION. 1-10. Hewlett-Packard uses a twoscctioii cigltbdigit scrial number (OOO-00000). If the first tlircc digits of tlic scrial number of your instrumcnt do not agrcc witti thosc on tlic title pag
11、e of this manual, changc sliects supplicd with tlic manual will explain the diffcrenccs bctwccii your instrument and the Model 412AIAll dcscribcd in lliis manual. 412A-A-30188 Figure 1.1. Model 412A DC Vacuum Tube Voltmctcr 00 1 295 0 h cy P Y 4b 4 J Model 4 12A 2-1. INTRODUCTION. SECTION II IN STAC
12、LATIO N 2-2. Tliis section contains instructions necessary for installation of the Model 412AIAR DC Vacuum Tube Voltmeter. Included are initial inspection procedures, power and grounding requirements, installation information, and instructions for repackaging for shipment. 2-3. INITIAL INSPECTION. 2
13、-4. This instrument was carefully inspected both mechanically and electrically before shipment. It should be free of mars or scratches, and in perfect electrical order upon receipt. To confirm this, the instrument should be inspected for physical damage in transit. Also test the clcctrical performan
14、ce of tlic instrument, using the procedure outlined in Paragraph 5-5. If there is damage or deficiency, see tlic warranty on the inside front cover of this manual. 2.5. POWER REQUIREMENTS. 2-6. The Model 412AIAR can be operated from any source of 115 or 230 volts at 50 or 60 Hz. The 115/230 V slide
15、switch on the rear panel selects the desired voltage. Power dissipation is approximately 35 watts. 2-7. G R 0 U N D I NG REQUl R EMENTS. 2-8. To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that tltc instrument panel and cabinet be grounded. This i
16、nstrument is equipped with a threeconductor power cable wluch, when plugged into an appropriate receptacle. grounds the instrument. The offset pin on the connector is tlie ground wire. 2-9. To preserve the protection feature when operating the instrument from a twocontact outlet, use a threeprong to
17、 two-prong adapter and connect the green pigtail on the adapter to ground. NOTE Operating the Model 412A/AR without grounding the third (power line ground) wire of the power cable will result in a zero offset of the meter and oscillation of the pointer. 2-1 0. INSTA 1 LATlO N. Section I1 2-1 I. The
18、Model 412A is intended for use as a bcncli instrument, having a top-mounted handle and rubbcr fcct. 2-12. The Model 412AR is intended for rack mounting. Front panel height is 5-7/32 inches. 2-13. REPACKAGING FOR SHIPMENT. 2-14. The following paragraphs contain a general guidc for repackaging of tlie
19、 instrument. Rcfcr to Paragraph 2-15 if the original container is to be uscd; 2-16 if it is not. If you have any questions, contact your local -lip- Salcs and Service Office. (SCC Appendix B for office locatiwis.) NOTE If the instrumcnt is to be sliippcd to I Icwlctt-iackard for scrvicc or repair. a
20、ttach a tag to tlic instrumcnt idcntifying the owncr and indicating tlic scrvicc or repair to be accomplislicd. lncludc tlic model number of tltc instrumcnt. In any corrcspondcnce, identify tlic instrumcnt by modcl numbcr, scrial numbcr prcfix, and scrial numbcr. 2-15. Place the instrumcnt in origin
21、al conhincr with suitable packing material and scat wcll with strong tapc or metal bands. If original containcr is not aviilablc, onc CBR be purchased from your ncarcst hp Salcs and Scrvicc Office. 2-16.lf original container is not to hc uscd, procccd as follows: a. Wrap instrument in hcavy papcr or
22、 plastic hcfurc placing in an inncr containcr. b. Place packing material around a11 sidcs of instrumcnt and protcct panel facc with cardhturd strips . c. Place instrument and inncr containcr in a hcavy carton or wooden box and scal wcll with strong tapc or metal hands. d. Mark shipping containcr “DI
23、LICATE INSTIWMENT,” “FRAGILE,” ctc. 00 1 29-5 2-1 hlodcl4 12A SECTION 111 0 PER AT1 N G 3-1. INTRODUCTION. 3-2. The -lip- Model 412A/AR DC Vacuum Tube Voltmeter nieasures dc voltages from 1.0 mV full scale to lo00 V full scale with an accuracy of 1% of full scale. Current measurement ranges are from
24、 0.001 mA full scale to 1000 mA full scale, with accuracy of 2% of full scale. The Model 41 2A/AR makcs resistaricc measurements from 1.0 ohm center scale to 100 megohms center scale. Resistance measurenicnt accuracy is 5% of reading between .3 and 3 on the ohms scale. A dc amplifier output is also