Rauland Telecenter Iv - Ctl1 Telephone Interface Module Installation 电路图.pdf
《Rauland Telecenter Iv - Ctl1 Telephone Interface Module Installation 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter Iv - Ctl1 Telephone Interface Module Installation 电路图.pdf(5页珍藏版)》请在收音机爱好者资料库上搜索。
1、KI-1681 CTL1 ChronoCom TL Telephone Interface Module Planning and Installation RAULAND-BORG CORPORATION ? 3450 West Oakton Street, Skokie, Illinois 60076-2951 ? (708) 679-0900 General Information Description This module enables an individual DTMF telephone or an electronic key system to control a Ch
2、ronoCom TL communications system. The telephone user can dial in- dividual rooms, answer call-ins by pressing a single push button, and use the keypad to select paging zones and distribute audio programs. Room stations can have non- dialing telephones as well as speakers. Refer to the attached wirin
3、g diagrams for the descrip- tions given in this section. “D” and “S” Series Systems In both “Dial-up” and “Switch-bank” Systems, all the above functions can be controlled by a DTMF telephone. In “Switch-bank” Systems, room-selector panels offer a ond way of distributing audio programming and pro- 6
4、two inputs for audio program sources. Related Equipment The CTLl module is meant to extend the functions of a ChronoCom TL communications system. The enhanced functions also require some additional equipment. Parts Supplied The module comes with the following parts: Two EPROMs labeled “U1” and “U2.”
5、 These replace the standard software chips in the 2524 Master Clock and Intercom Controller, to add the CTLl telephone functions. Four stand-offs (feet) with adhesive tape for sur- face-mounting the module. A 34-pin flat cable and two connectors, for linking the module with the 2524. In early units,
6、 these came unassembled. Standard System Equipment 2524 Master Clock and Intercom Controller: This provides the basic control functions for intercom as well as full master-clock functions (updating secondary clocks, ringing bells, providing music during class changes, and controlling lights and equi
7、pment via re- lays). Note: The 34-pin ejector header for the flat cable from TLI is not installed on early 2524 units. This SM0316- can be ordered from Rauland-Borg. Speaker-Control Panels: Rauland switch and relay panels can each handle 25 room stations. In “D” Series systems, TC4130 rack-mount rel
8、ay panels switch room speakers individually for intercom functions, and in groups for sending pages and distributing audio programs. In S” Series systems, which can control program dis- tribution by manual switches as well as by dialing, use a combination of SW25 switch panels and TC4110 relay panel
9、s. The SW25 has a three-position toggle switch for each room, which allows the manual selection of two different audio sources. Important: Be sure to set the DIP switch in each TC4110 or TC4130 panel (see the 2524 installation man- ual, KI-1628). Intercom Amplifier: The Rauland TC4160 Voice- Control
10、 Module (VCM2) enables a telephone to talk with a room speaker. The VCM2 is normally in the “listen” mode, so that the administrative telephone can hear the room. However. when the administrative telephones user begins speaking into the mouthpiece, the VCM2 automatically switches to the “talk” mode.
11、 Only one mod- ule is needed in a system. Administrative Telephone: The CTL1 will accept one line for DTMF telephones. This line can serve a single DTMF (dual-tone, multiple-frequency) phone, or it can accept a line from the trunk port of an electronic key system. Display: To give the user essential
12、 feedback (the num- ber of a room calling in, zones selected, etc.), each con- trol telephone should have a display. A TC4200 Vacuum Fluorescent Display can be mounted on a wall. where its large, bright display can serve more than one telephone (see N-1460). Alternatively, TC4220 Digital Displays ca
13、n be attached to individual telephones (see KI-1590). Con- sult these manuals for the limits on both the number of displays that can be used and on their distance from the central system. Power Amplifiers: Sending paging announcements requires a power amplifier capable of driving all room speakers a
14、t once. An amplifier wired to the CTL1s “Amp In” output will handle both program material from one 1991 RAULAND-BORG CORPORATION ? Printed in U.S.A. Page 1 of 5 Orig. 11/91 168100 RadioFans.CN 收音机爱 好者资料库 CTL1 ChronoCom Telephone Module-Installation Optional Central Equipment The following cquipment
15、provides enhancements be- y o n d t h e b a s i c i n t e r c o m f u n c t i o n s : call-ins. However, privacy switches cannot be used on standard TL systems, because the privacy function has been replaced with the staff-telephone call-in function. Adding the privacy function to a system without s
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Telecenter Iv Ctl1 Telephone Interface Module Installation 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220856.html



Marshall-9100-62-02-Schematic电路原理图.pdf