Technics-SAEH570-rec-sm 电路图 维修手册.pdf
《Technics-SAEH570-rec-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Technics-SAEH570-rec-sm 电路图 维修手册.pdf(74页珍藏版)》请在收音机爱好者资料库上搜索。
1、Table Of Contents COVER 1 Before Repairs 2 Protection Circuitry 3 Accessories 4 Caution for AC Mains Lead 5 Location of Controls 6 Operation Checks and Component Replacement Procedures 6.1 Checking for the AC IN P.C.B. 6.2 Checking for the operation P.C.B. 6.3 Checking for the main P.C.B. 6.4 Replac
2、ement for the regulator transistor 6.5 Replacement for the power IC 7 To Supply Power Source 8 Self-Diagnostic Function 8.1 To display the malfunction code 8.2 To return to the normal display 8.3 Display contents 8.3.1 U70 CD, U70 DECK (displayed automatically) 8.3.2 F61 9 Schematic Diagram Notes 10
3、 Schematic Diagram 11 Printed Circuit Board Diagram 12 Type Illustration of ICs, Transistors and Diodes 13 Wiring Connection Diagram 14 Block Diagram 15 Terminal Function of ICs 15.1 IC901 (C2BBFD000297):System ControlFL Drive 16 Replacement Parts List 17 Cabinet Parts Location 18 Packaging Service
4、Manual TOP NEXT AD0102030C2 Tuner/Amplifier G SA-EH570 Colour (S).Silver Type Areas (E).Europe. (EB).Great Britain. (EG).Germany, Italy, France, Netherlands and Denmark. (EP).East Europe and CIS. 2001 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution
5、 is a violation of law. RadioFans.CN 收音机爱 好者资料库 1 Before Repairs TOP PREVIOUS NEXT 1. Turn off the power supply. Using a 10 , 10 W resistor, connect both ends of power supply capacitors (C701, C703 and C702, C704) in order to discharge the voltage. 2. Before turning the power supply on, after comple
6、tion of repair, slowly apply the primary voltage by using a power supply voltage controller to make sure that the consumed current at 50 Hz in NO SIGNAL mode should be shown below with respectto supply voltage 230/240 V. Power supply voltageAC 230 V AC 240 V Consumed current 50 Hz70 300 mA TOP PREVI
7、OUS NEXT RadioFans.CN 收音机爱 好者资料库 2 Protection Circuitry TOP PREVIOUS NEXT The protection circuitry may have operated if either of the following conditions is noticed: G No sound is heard when the power is switched ON. G Sound stops during a performance. The functions of this circuitry is to prevent
8、circuitry damage if, for example, the positive and negative speaker connection wires are shorted, or if speaker systems with an impedance less than the indicated rated impedance of this unit are used. If this occurs, follow the procedures outlined below. 1. Switch OFF the power. 2. Determine the cau
9、se of the problem and correct it. 3. Switch ON the power once again. Note: When the protection circuitry functions, the unit will not operate unless the power is first switched OFF and then ON again. TOP PREVIOUS NEXT RadioFans.CN 收音机爱 好者资料库 3 Accessories TOP PREVIOUS NEXT G AC power supply cord for
10、 (E), (EG), (EP) areas/(RJA0019-1X).1 pc. G AC power supply cord for (EB) area/(RJA0053-2X).1 pc. G AM loop antenna set/(RSA0022-L).1 pc. G FM indoor antenna/(RSA0007).1 pc. G Speaker cords/(REE0853).2 pcs./(REE1057).2 pcs. G Remote control transmitter/(EUR7702070).1 pc. G Remote control batteries/(
11、R6/LR6, “AA”, UM-3).2 pcs. Note: These are available on sales route. G Antenna plug adaptor for (EB) area only/(SJP9009).1 pc. TOP PREVIOUS NEXT 4 Caution for AC Mains Lead TOP PREVIOUS NEXT TOP PREVIOUS NEXT 5 Location of Controls TOP PREVIOUS NEXT TOP PREVIOUS NEXT 6 Operation Checks and Component
12、 Replacement /Procedures TOP PREVIOUS NEXT G This section describes procedures for checking the operation of the major printed circuit boards and replacing the main components. G For reassembly after operation checks or replacement, reverse the respective procedures. Special reassembly procedures ar
13、e described only when required. 6.1 Checking for the AC IN P.C.B. 6.2 Checking for the operation P.C.B. 6.3 Checking for the main P.C.B. 6.4 Replacement for the regulator transistor 6.5 Replacement for the power IC TOP PREVIOUS NEXT 6.1 Checking for the AC IN P.C.B. TOP PREVIOUS NEXT G Check the AC
14、IN P.C.B. as shown below. TOP PREVIOUS NEXT 6.2 Checking for the operation P.C.B. TOP PREVIOUS NEXT G Follow the (Step 1) - (Step 3) of item 6.1. G Check the operation P.C.B. as shown below. 6.3 Checking for the main P.C.B. TOP PREVIOUS NEXT G Follow the (Step 1) - (Step 3) of item 6.1. G Follow the
15、 (Step 1) - (Step 6) of item 6.2. G Check the main P.C.B. as shown below. TOP PREVIOUS NEXT 6.4 Replacement for the regulator transistor TOP PREVIOUS NEXT G Follow the (Step 1) - (Step 3) of item 6.1. TOP PREVIOUS NEXT 6.5 Replacement for the power IC TOP PREVIOUS NEXT G Follow the (Step 1) - (Step
16、3) of item 6.1. G Follow the (Step 1) - (Step 6) of item 6.2. G Follow the (Step 1) - (Step 10) of item 6.3. TOP PREVIOUS NEXT 7 To Supply Power Source TOP PREVIOUS NEXT This unit SA-EH570 is designed to operate on power supplied form system connected. /For system connection, refer to Fig. 7-1. Fig.
17、 7-1. When the unit SA-EH570 has to test and service alone, use the following method to supply power source. 1. Short the section between W902A Pin 3 and C740 (-) (GND). (Refer to Fig. 7-2. ) 2. Connect this unit to an AC power supply cord./(This unit come to stand-by mode.) 3. Turn the unit ON. Fig
18、. 7-2. Notes: Use only this method when checking the voltage etc./In case of checking the operations, use the system connections to supply power source. TOP PREVIOUS NEXT 8 Self-Diagnostic Function TOP PREVIOUS NEXT This unit is equipped with a self-diagnostic function which, in the event of a malfu
19、nction, automatically displays a code indicating the nature of the malfunction. Use this self-diagnostic function when servicing the unit. 8.1 To display the malfunction code 8.2 To return to the normal display 8.3 Display contents 8.3.1 U70 CD, U70 DECK(displayed automatically) 8.3.2 F61 TOP PREVIO
20、US NEXT 8.1 To display the malfunction code TOP PREVIOUS NEXT G U70 CD:/U70 DECK: Automatically displays on the tuner/amplifier when a malfunction occurs. Refer to Fig. 8-1. G F61: Automatically displays on the tuner/amplifier when a malfunction occurs. Refer to Fig. 8-1. Fig. 8-1. TOP PREVIOUS NEXT
21、 8.2 To return to the normal display TOP PREVIOUS NEXT 1. For U70 CD/U70 DECK H Press an any operation button on the tuner/amplifier. H To re-display the code, switch the power off (POWER STANDBY button), and then switch power back on again. 2. For F61 H If F61 is displayed, the power will automatic
22、ally be switched off and the standby indicator will light up. H F61 will be displayed for 3 seconds, and then the clock will be displayed. H To re-display the code, switch the power on. F61 will be re-displayed, and then after 3 seconds the clock will be displayed and the power will automatically sw
23、itch off. TOP PREVIOUS NEXT 8.3 Display contents TOP PREVIOUS NEXT 8.3.1 U70 CD, U70 DECK(displayed automatically) 8.3.2 F61 TOP PREVIOUS NEXT 8.3.1 U70 CD, U70 DECK/(displayed automatically) TOP PREVIOUS NEXT G Problem or condition A bus-line communications error has occurred as a result of the fla
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Technics-SAEH570-rec-sm 电路图 维修手册 Technics SAEH570 rec sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf