Panasonic-SAAK580P-cs-sm 电路图 维修手册.pdf
《Panasonic-SAAK580P-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAAK580P-cs-sm 电路图 维修手册.pdf(44页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2009. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG0905048CE CD Stereo System Model No.SA-AK580PH SA-AK580PN Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 4 1.1. General Guidelines- 4 1.2. Before Use (For
2、 PH only)- 4 1.3. Caution For Fuse Replacement- 4 1.4. Before Repair and Adjustment- 5 1.5. Protection Circuitry- 5 1.6. Safety Parts Information-5 2 Warning -7 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive (ES) Devices-7 2.2. Precaution of Laser Diode-8 2.3. Service ca
3、ution based on Legal restrictions -9 Notes: This models CD Mechanism Unit (CR14C). Please refer to the Original Service Manual (Order No. MD0805031CE) for this CD Mechanism Unit. RadioFans.CN 收音机爱 好者资料库 17 6Self-Diagnosis and Special Mode Setting This unit is equipped with features od self-diagnosis
4、 & special mode setting for checking the function & reliability. Special Note: Checking of the reliability (ageing) & changer operation must be carry out to ensure good working condition in unit. 6.1.Doctor Mode Summary Table Main unit buttonsRemote control unit buttonsApplicationNote 4, 7Doctor Mod
5、e(Refer to the section “6.2.1 Doctor Mode Table 1” for more information.) Doctor ModeDISPLAYCold Start 2Micro-P Version Display 7Volume 50 Setting Check(Refer to the section “6.2.2 Doctor Mode Table 2” for more information.) 8Volume 35 Setting Check 9Volume 0 Setting Check PLAYMODE/-REPEATVolume 30
6、Setting Check 1FL Display Check DELCD Open Test , 1, 1 CR14 Reliability Test 1 (no retry) , 1, 2 CR14 Reliability Test 2 (with retry) DISCCR14 Changer Mechanism Check(Refer to the section “6.2.3 Doctor Mode Table 3” for more information.) , 9, 4 CR14 Error Late Display 4CD to USB Recording & Playing
7、 Inspection(Refer to the section “6.2.4 Doctor Mode Table 4” for more information.) FM/AMTuner Inspection OKExit Inspection Mode RadioFans.CN 收音机爱 好者资料库 18 6.2.Doctor Mode Table Below is the various special modes for checking:- 6.2.1.Doctor Mode Table 1 ItemFL DisplayKey Operation Mode NameDescripti
8、onFront Key Doctor ModeTo enter into Doctor Mode. In CD Mode: 1. Press button on main unit fol- low by 4 and 7 on remote control. To exit Doctor Mode, press OK button on remote control. Cold StartTo activate cold start upon next power up when reset is execute the next time. In Doctor Mode: 1. Press
9、DISPLAY button on remote con- trol. Micro-P Version Display To check the firmware version for Jupiter & Microprocessor IC. Display 1 Display 2 In Doctor Mode: 1. Press 2 button on remote control. RadioFans.CN 收音机爱 好者资料库 19 6.2.2.Doctor Mode Table 2 ItemFL DisplayKey Operation Mode NameDescriptionFro
10、nt Key Volume Setting Check To check for the volume setting of the main unit. The volume will be auto- matically set to its respec- tive level (in dB). During this mode, treble/bass/EQ will be set to 0dB & OFF. Display 1In Doctor Mode: 1. Press 7 button on remote control. To exit Doctor Mode, press
11、OK button on main unit or remote control. Display 1In Doctor Mode: 2. Press 8 button on remote control. To exit Doctor Mode, press OK button on main unit or remote control. Display 1In Doctor Mode: 3. Press 9 button on remote control. To exit Doctor Mode, press OK button on main unit or remote contr
12、ol. Display 1In Doctor Mode: 4. Press PLAY MODE/-REPEAT button on remote control. To exit Doctor Mode, press OK button on main unit or remote control. FL Display Check To check the FL segments display (All segments will light up) In Doctor Mode: 1. Press 1 button on remote control. CD OPEN Test To c
13、heck the CD OPEN operation. In Doctor Mode: 1. Press DEL button on remote control. 2. Press OPEN/CLOSE button on main unit to close the disc tray. CR14 Reliability Test1 (no retry) Note: 1. If the mechanism error occurs, it should stop the test. (no retry, no recov- ery process). 2. The test mode is
14、 cleared by power OFF. 3. Reading and play- back should not be done. In Doctor Mode: 1. Press , 1, 1 button on remote con- trol. CR14 Reliability Test2 (with retry) Note: 1. Even if the mecha- nism error occurs, it should retry as nor- mal operation. 2. The test mode is cleared by power OFF. 3. Read
15、ing and play- back should not be done. In Doctor Mode: 1. Press , 1, 2 button on remote con- trol. 20 6.2.3.Doctor Mode Table 3 ItemFL DisplayKey Operation Mode NameDescriptionFront Key CR14 Inspection Below is the process: 1. Load TRAY 1 (Move to PLAY position) 2. After that, TRAY 2 is open (TRAY 1
16、 still in LOAD condition) and close. 3. Next TRAY 3 is open (TRAY 1 still in LOAD condition) and close. 4. Then TRAY 4 is open (TRAY 1 still in LOAD condition) and close. 5. Finally TRAY 5 is open (TRAY 1 still in LOAD condition) and close. 6. Tray 1 is unloaded. (Move to the STOCK position) 7. Tray
17、 1 is loaded. (Move to the PLAY position) When step 1 to 7 operates nor- mally without any error, FL will display CHGR_OK_ In Doctor Mode: 1. Press DISC button on remote con- trol. CR14 Error Code Display To display errors codes for CR14 changer mechanism. Refer to section 6.4.1 (CD Mechanism (CR14)
18、 Error code table). In Doctor Mode: 1. Press , 9, 4 button on remote control. 21 6.2.4.Doctor Mode Table 4 ItemFL DisplayKey Operation Mode NameDescriptionFront Key CD to USB Recording & Playing Inspection -Automatically change to CD -Set it to VOL 0 -Preset EQ Set to FLAT USB Formatted When high-sp
19、eed recording When analog recording - Switches to the USB selector after an analog recording ends (TRACK 1 of ALBUM1) During playback this track - Sets to VOL 50 (0dB) and start playback - It is enabled to accept the SKIP key and the ALBUM key Next, play the track analog recorded. (TRACK1 of ALBUM2)