Panasonic-SAAKX73P-cs-sm 电路图 维修手册.pdf
《Panasonic-SAAKX73P-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAAKX73P-cs-sm 电路图 维修手册.pdf(138页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2012. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1206005CE A6 CD Stereo System Model No.SA-AKX73P Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 3 1.1. General Guidelines- 3 1.2. Before Repair and Adjust
2、ment- 4 1.3. Protection Circuitry- 4 1.4. Caution For Fuse Replacement- 4 1.5. Safety Parts Information- 5 2 Warning- 6 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive (ES) Devices - 6 2.2. Precaution of Laser Diode- 7 2.3. Service caution based on Legal restrictions- 8 2
3、.4. Handling Precautions for Traverse Unit- 9 3 Service Navigation-11 3.1. Service Information -11 4 Specifications -12 5 General/Introduction- 13 5.1. Media Information- 13 6 Location of Controls and Components- 14 6.1. Remote Control Key Button Operation - 14 6.2. Main Unit Key Button Operation- 1
4、5 7 Installation Instructions - 16 7.1. Speaker and A/C Connection- 16 8 Service Mode- 17 8.1. Cold-Start - 17 8.2. Doctor Mode Table- 18 8.3. Reliability Test Mode (CD Mechanism Unit (BRS11C) - 21 8.4. Self-Diagnostic Mode - 22 8.5. Self-Diagnostic Error Code Table- 22 8.6. Sales Demonstration Lock
5、 Function - 23 Please refer to the original service manual for: ? ? CD Mechanism Unit (BRS11C), Order No. PSG1201019AE ? ? Speaker system SB-AKX73P-K, Order No. PSG1206006AE RadioFans.CN 收音机爱 好者资料库 2 9 Troubleshooting Guide-24 9.1. Part Location -24 9.2. Troubleshooting Guide for F61 and/or F76-28 9
6、.3. D-Amp IC Operation X: NG (In case that time out happens.) : Either one of FOAOC, TR AOC and FO coarse AGC is NG. : If theAGC is NG (ignore others). 2.To cancel, press 0 on remote control . 2.To cancel, press 0 on remote control . ROM Version (Display 1) (Display 2) Year Develop Year Develop ROM
7、Type Version(Decimal) after 2 sec Version (Decimal )Checksum (Hex) 21 8.3.Reliability Test Mode (CD Mechanism Unit (BRS11C) Below is the process flow chart of the aging test for the CD Mechanism Unit (BRS11C). Fig. 1. Reliability Test (Loading) Fig. 2. Reliability Test (Traverse) Fig. 3. Reliability
8、 Test (Combination) OPEN Operation OPEN wait for 1 s CLOSE Operation CLOSE wait for 4 s Count up First Track Access First Track Play 5 s Last Track Access Last Track Play 5 s Count up First Track Access Access Play 10 s Open Operation Open wait for 1 s CLOSE Operation Count up First Track Last Track
9、 Last Track Play 10 s 22 8.4.Self-Diagnostic Mode 8.5.Self-Diagnostic Error Code Table Self-Diagnostic Function (Refer Section 8.4. Self-Diagnostic Mode) provides information on any problems occurring for the unit and its respective components by displaying the error codes. These error code such as
10、U*, H* and F* are stored in memory and held unless it is cleared. The error code is automatically display after entering into self-diagnostic mode. 8.5.1.Power Supply Error Code Table FL Display Key Operation Front Key Item Description Mode Name To enter into self diagnostic checking System will per
11、form a check on any unusual/error code from the memory To clear the stored in memory (EEPROM IC) Self Diagnostic Mode Error code information Delete error code Step 1: Select CD mode (Ensure no disc is inserted). Step 2: Press & hold follow by / on main unit for 2 seconds. Step 1: In self diagnostic
12、mode, Press on main unit. To exit, press /I on main unit or remote control. Step 1: In self diagnostic mode, Press 0 on remote control. To exit, press /I on main unit or remote control. Example: 23 8.5.2.CD Mechanism Error Code Table (CD Mechanism Unit (BRS11C) 8.6.Sales Demonstration Lock Function
13、8.6.1.Entering into sales Demo Mode Here is the procedures to enter into Sales Demonstration Lock. Step 1: Turn on the unit. Step 2: Select to any mode function. Step 3: Press OPEN/CLOSE key then / key at the same time,press and hold both OPEN/CLOSE and / keys for 5 sec. Step 4: The display will sho
14、w upon entering into this mode for 2 sec. Note: OPEN/CLOSE button is invalid and the main unit displays “LOCKED” while the lock function mode is entered. 8.6.2.Cancellation Step 1: Turn on the unit. Step 2: Select to any mode function. Step 3: Press OPEN/CLOSE key then / key at the same time,press a
15、nd hold both OPEN/CLOSE and / keys for 5 sec. Step 4: The display will show upon entering into this mode for 2 sec. Error CodeDiagnostic ContentsDescription of errorAutomatic FL DisplayRemarks CD H15CD Open AbnormalDuring operation POS_SW_R On fail to be detected with 4 sec. Error No. shall be clear
16、 by force or during cold start. Press on main unit for next error. CD H16CD Closing AbnormalDuring operation POS_SW_CEN On fail to be detected with 4 sec. Error No. shall be clear by force or during cold start. Press on main unit for next error. F26Communication between CD servo LSI and micro-p abno
17、rmal. During switch to CD func- tion, if SENSE = “L” within failsafe time of 20ms. Press on main unit for next error. 24 9Troubleshooting Guide 9.1.Part Location 9.1.1.SMPS P.C.B. Fig. 1 SMPS P.C.B. Thermistor : TH5861 Photocoupler : PC5720 AC Inlet : P5701 Fuse : F1 Photocoupler : PC5702, PC5799 Sw
18、itching Regulator IC: IC5701 SMPS Control IC: IC5799 Main Transformer : T5701 Rectifier Diode : D5801, D5802 Connector: CN5802 Sub Transformer : T5751 Sub Transformer : D5798 25 9.1.2.Main P.C.B. (Front Side) Fig. 2 Main P.C.B. (Front Side) 26 Fig. 3 Main P.C.B. (Back Side) Audio Digital Amp IC IC58
19、00 Voltage Regulator IC IC2010 Resistor Defective R5803 Resistor Defective R5805 Audio Digital Amp IC IC5700 Regulator Circuit Q2022 D2004 Regulator Circuit L2000 L2001 Regulator Circuit Voltage Regulator IC IC2011 Resistor Defective R5802 Resistor Defective R5704 Resistor Defective R5705 Resistor D
20、efective R5702 Resistor Defective R5703 Resistor Defective R5804 27 9.1.3.D-AMP P.C.B. Fig. 4 D-Amp P.C.B. Audio Digital Amp IC: IC5900 Resistor Defective R5905 Resistor Defective R5917 Resistor Defective R5922 Resistor Defective R5921 28 9.2.Troubleshooting Guide for F61 and/or F76 This section ill
21、ustrates the checking procedures when upon detecting the error of “F61” and/or “F76” after power up of the unit. It is for purpose of troubleshooting and checking in SMPS, Main & D-Amp P.C.B. 5Switching Regulator 5IC5701 Faulty . 6 T5751 Faulty. Switching Mode Power Supply Control IC (IC5799) faulty
22、. Set can ON1Speaker Output1Faulty speaker unit, Loose connection, Short. then F61 2D-AMP circuit D-AMP IC, IC5700, IC5800, IC5900 defective. (Check DC voltage at speaker terminals, 3V and above defective) DC Voltage ok but no sound, check DC Voltage at Pin 1 . 2a, 2b ok but no sound, check PWM wave
23、form at Pin 10 and Pin 14 . If no PWM, 12 resistors defective. Set can ON 1Main Transformer T5701Short circuit between Pin 11 and Pin 12 . then F76 1b Short circuit between Pin 13 and Pin 14 . 1c Short circuit between Pin 16 and Pin 17 . 2 2 Regulator Circuits 2a 2b 2c 3 Q2022 faulty (No +5V output)
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Panasonic-SAAKX73P-cs-sm 电路图 维修手册 Panasonic SAAKX73P cs sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf