1、I IAMPLIFIER SECTION RMS output power: Dolby Digital Mode T.H.D. 10% (Each channel driven) 1 kHz front CH 150 W per channel (6 ) 1 kHz surround CH 80 W per channel (4 ) 1 kHz center CH 80 W per channel (4 ) Total RMS output power540 W RMS output power: STEREO Mode T.H.D. 10% 1 kHz front CH 150 W per
2、 channel (6 ) Total harmonic distortion Half power at 1 kHz (Front CH)0.5% (6 ) Input sensitivity DVD-P,TV,BD/DVR450 mV, IHF66 S/N at rated power (6 ) DVD-P,TV,BD/DVR 80 dB (85 dB, IHF66) Input impedance DVD-P,TV,BD/DVR 47 k Tone controls BASS50 Hz, +6 dB to -6 dB TREBLE20 kHz, +6 dB to -6 dB Load i
3、mpedance Front (L/R)6 to 8 2007 Matsushita Electric Industrial Co. Ltd. All rightsreserved.Unauthorizedcopyingand distribution is a violation of law. SA-HR50E SA-HR50EG Colour (S).Silver Type (K).Black Type Surround (L/R)4 to 8 Center4 to 8 Digital input OPTICAL2 COAXIAL1 HDMI Input2 HDMI Onput1 I I
4、FM TUNER SECTION Frequency range 87.50 MHz to 108.00 MHz Sensitivity S/N 30 dB1.9 V/75 S/N 26 dB1.8 V/75 S/N 20 dB1.6 V/75 IHF usable sensitivity(IHF58) 2.2 V/75 IHF 46 dB stereo quieting sensitivity22 V/75 Total Harmonic distortion MONO0.2% STEREO0.3% S/N MONO60 dB (71 dB, IHF) STEREO58 dB (65 dB,
5、IHF) Frequency response 20 Hz to 15 kHz, +1 dB, -2 dB Image rejection at 98 MHz40 dB IF rejection at 98 MHz70 dB Stereo separation (1 kHz)40 dB Antenna terminal75 (unbalanced) AV Control Receiver Specification ORDER NO. MD0708021CE RadioFans.CN 收音机爱 好者资料库 I IAM TUNER SECTION Frequency range 522 kHz
6、to 1611 kHz (9 kHz steps) 530 kHz to 1620 kHz (10 kHz steps) Sensitivity500 V/m Selectivity (at 999 kHz)35 dB I IGENERAL Power supply AC 230 V to 240 V, 50 Hz 1 Safety Precautions 3 2 Prevention of Electro Static Discharge (ESD) to Electrostatically Sensitive (ES) Devices 4 3 About Lead Free Solder
7、(PbF) 5 4 Accessories 6 5 Operation Procedures 7 6 Self Diagnosis and Special Mode Setting 12 7 Assembling and Disassembling 15 8 Service Positions 33 9 Voltage Measurement and Waveform Chart 38 Power consumption125 W Dimensions (W H D) 430 mm x 105 mm x 389 mm Massapprox. 4.0 kg Power consumption i
8、n standby mode:1 W Notes: 1. Specifications are subject to change without notice. 2. Total harmonic distortion is measured by the digital spectrum analyzer. 10 Wiring Connection Diagram 47 11 Block Diagram 49 12 Notes of Schematic Diagram 55 13 Schematic Diagram 57 14 Printed Circuit Board Diagram 7
9、3 15 Illustrations of ICs, Transistors & Diodes 81 16 Terminal Functions of Integrated Circuits 82 17 Exploded Views 83 18 Replacement Parts List 85 CONTENTS Page Page 2 -HR50E / SA-HR50EG RadioFans.CN 收音机爱 好者资料库 1 Safety Precautions 1.1. General Guidelines 1. When servicing, observe the original le
10、ad dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed. 3. After servicing, make the following lea
11、kage current checks to prevent the customer from being exposed to shock hazards. 1.1.1. Leakage Current Cold Check 1. Unplug the AC cord and connect a jumper between the two prongs on the plug. 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic
12、cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading should be between 1M and 5.2. When the exposed metal does not have a return path to the chassis, the reading must be. 1.1.2. Leakage Current
13、 Hot Check (See Figure 1.) 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a 1.5k, 10 watts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and a good earth ground such as a water pipe, as sh
14、own in Figure 1. 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potent
15、ial at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the
16、equipment should be repaired and rechecked before it is returned to the customer. Fig. 1 1.2. Before Repair and Adjustment Disconnect AC power, discharge Power Supply Capacitors C707, C804, C859, C860 & C861, C540, C541, C544, C545, C594, C595, C644, C645, C694, C695, C5508 & C5509 through a 10 , 1W
17、 resistor to ground. DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices. After repairs are completed, restore power gradually using a variac, to avoid overcurrent. Current consumption at AC 230 V - 240 V, 50Hz in NO SIGNAL mode should be 2
18、00 800 mA . 1.3. Protection Circuitry The protection circuitry may have operated if either of the following conditions is noticed: *No sound is heard when the power is supplied. *Sound stops during a performance. The functions of this circuitry is to prevent circuitry damage, for example, the positi
19、ve and negative speaker connection wires are “shorted”, or if speaker systems with an impedance less than the indicated rated impedance of this unit are used. If this occurs, follow the procedure outlined below: 3 SA-HR50E / SA-HR50 RadioFans.CN 收音机爱 好者资料库 1. Press the STANDBY/ON button, switch to S
20、TANDBY mode. 2. Determine the cause of the problem and correct it. 3. Press the STANDBY/ON button once again, supply the power. Note: When the protection circuitry functions, the unit will not operate unless the STANDBY/ON button is first switched STANDBY and then ON again. 1.4. Safety Part Informat
21、ion Safety Parts List: There are special components used in this equipment which are important for safety. These parts are marked byin the Schematic Diagrams & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent shock, fi
22、re or other hazards. Do not modify the original design without permission of manufacturer. Table 1 Reference No.Part No.Part Name & DescriptionRemarks DZ701ERZV10V511CSZENERM TH701D4CAC8R00002THERMISTORM TH702D4CC11040013THERMISTORM L701ELF18N067ECOMMON MODE COILM L702ELF21N015ECOMMON MODE COILM L70
23、3ELF21N015ECOMMON MODE COILM T701ETS48AA196ACMAIN TRANSFORMERM T721ETS25AD1P6AGBACKUP TRANSFORMERM T800ETS28AU3G9ACSUB TRANSFORMERM PC701B3PBA0000402PHOTO COUPIERM PC721B3PBA0000402PHOTO COUPIERM RY721K6B1AEA00003PC POWER RELAYM F1K5D402BLA013FUSE T4AL 250VM P701K2AA2B000017AC INLETM A2K2CQ2CA00007A
24、C CORDM C701ECQU2A334MLA0.33 100VM C703F1BAF10200201000PM C704F1BAF10200201000PM C706ECQU2A104MLC0.1 100VM C714F1BAF10200201000PM C732F1BAF10200201000PM 2 Prevention of Electro Static Discharge (ESD) to Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Panasonic-SAHR50E-avr-sm 电路图 维修手册 Panasonic SAHR50E avr sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
GRUNDIG Musikgerät 87电路原理图.jpg