Nad-S-400-Service-Manual(1) 电路图 维修手册.pdf
《Nad-S-400-Service-Manual(1) 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Nad-S-400-Service-Manual(1) 电路图 维修手册.pdf(30页珍藏版)》请在收音机爱好者资料库上搜索。
1、Preliminar y NANAD D S 400 RDS FM TUNER SERVICE MANUAL SERVICE MANUAL S 400 RDS FM TUNER S 400 RDS FM TUNER NANAD D All rights reserved. No part this publication may be reproduced, stored or transmitted in any form without the written permission of NAD Electronics International 2003 NAD ELECTRONICS
2、INTERNATIONAL ONTARIO, CANADA RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT IN ANY WAY, NEVER PERFORM CUSTOMIZED INSTALLATIONS WITHOUT MANUFAC- TURERS APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLY VOID THE WARRANTY, BUT MAY LEAD TO YOUR BEING LI
3、ABLE FOR ANY RESULTING PROPERTY DAMAGE OR USER INJURY. SERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOU ARE THOROUGHLY FAMILIAR WITH ALL OF THE FOLLOWING SAFETY CHECKS AND SERVICING GUIDELINES. TO DO OTHERWISE, INCREASES THE RISK OF POTENTIAL HAZARDS AND INJURY TO THE USER. WHILE SERVICING, USE AN IS
4、OLATION TRANSFORMER FOR PROTEC- TION FROM A.C. LINE SHOCK. SAFETY CHECKS AFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRECTED. A CHECK SHOULD BE MADE OF THE FOLLOWING. SUBJECT : FIRE CONNECT A 1500 OHM 10 WATT RESIS- TOR, PARALLELED BY A .15 MFD. 150.V A.C TYPE CAPACITOR BETWEEN A KNOWN GOOD EARTH
5、GROUND (WATER PIPE, CON- DUIT, ETC.) AND THE EXPOSED METALLIC PARTS, ONE AT A TIME. MEASURE THE A.C. VOLTAGE ACROSS THE COMBINATION OF 1500 OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE A.C. PLUG AND REPEAT A.C. VOLTAGE MEASUREMENTS FOR EACH EXPOSED METALLIC PART. VOLTAGE MEASURED MUST NOT EXCEED
6、75 VOLTS R.M.S. THIS CORRESPONDS TO 0.5 MILLIAMP A.C ANY VALUE EXCEEDING THIS LIMIT CONSTITUTES A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED IMMEDIATELY. SUBJECT: GRAPHIC SYMBOLS THE LIGHTNING FLASH WITH APROWHEAD SYMBOL. WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE SERVICE PERSONNEL T
7、O THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” THAT MAY BE OF SUFFICIENT MAG- NITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK. THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIAN- GLE IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF IMPORTANT SAFETY INFORMATION IN SERVICE LITERATURE. SUB
8、JECT : X-RADIATION 1. BE SURE PROCEDURES AND INSTRUCTIONS TO ALL SERVICE PER- SONNEL COVER THE SUBJECT OF X-RADIATION. THE ONLY POTEN- TIAL SOURCE OF X-RAYS IN CURRENT T.V. RECEIVERS IS THE PIC- TURE TUBE. HOWEVER, THIS TUBE DOES NOT EMIT X-RAYS WHEN THE HIGH VOLTAGE IS AT THE FACTORY SPECIFIED LEVE
9、L. THE PROPER VALUE IS GIVEN IN THE APPLICABLE SCHEMATIC. OPERA- TION AT HIGHER VOLTAGES MAY CAUSE A FAILURE OF THE PIC- TURE TUBE OR HIGH VOLTAGE SUPPLY AND, UNDER CERTAIN CIR- CUMSTANCES, MAY PRODUCE RADIATION IN EXCESS OF DESIR- ABLE LEVELS. 2. ONLY FACTORY SPECIFIED C.R.T. ANODE CONNECTORS MUST
10、BE USED. DEGAUSSING SHIELDS ALSO SERVE AS AN X-RAY SHIELD IN COLOR SETS, ALWAYS RE-INSTALL THEM. 3. IT IS ESSNTIAL THAT SERVICE PERSONNEL HAVE AVAILABLE AN ACCURATE AND RELIABLE HIGH VOLTAGE METER. THE CALIBRA- TION OF THE METER SHOULD BE CHECKED PERIODICALLY AGAINST A REFERENCE STANDARD, SUCH AS TH
11、E ONE AVAILABLE AT YOUR DISTRIBUTOR. 4. WHEN THE HIGH VOLTAGE CIRCUITRY IS OPERATING PROPERLY THERE IS NO POSSIBILITY OF AN X-RADIATION PROBLEM. EVERY TIME A COLOR CHASSIS IS SERVICED. THE BRIGHTNESS SHOULD BE RUN UP AND DOWN WHILE MONITORING THE HIGH VOLTAGE WITH A METER TO BE CERTAIN THAT THE HIGH
12、 VOLTAGE DOES NOT EXCEED THE SPECIFIED VALUE AND THAT IT IS REGULATING CORRECTLY. WE SUGGEST THAT YOU AND YOUR SERVICE ORGA- NIZATION REVIEW TEST PROCEDURES SO THAT VOLTAGE REGU- LATION IS ALWAYS CHECKED AS A STANDARD SERVICING PROCE- DURE AND THAT THE HIGH VOLTAGE READING BE RECORDED ON EACH CUSTOM
13、ERS INVOICE. 5. WHEN TROUBLESHOOTING AND MAKING TEST MEASUREMENTS IN A PRODUCT WITH A PROBLEM OF EXCESSIVE HIGH VOLTAGE, AVOID BEING UNNECESSARILY CLOSE TO THE PICTURE TUBE AND THE HIGH VOLTAGE SUPPLY. DO NOT OPERATE THE PRODUCT LONGER THAN IT IS NECESSARY TO LOCATE THE CAUSE OF EXCES- SIVE VOLTAGE.
14、 6. REFER TO HV. B+ AND SHUTDOWN ADJUSTMENT PROCEDURES DESCRIBED IN THE APPROPRIATE SCHEMATIC AND DIAGRAMS (WHERE USED). SUBJECT: IMPLOSION 1. ALL DIRECT VIEWED PICTURE TUBES ARE EQUIPPED WITH AN INTE- GRAL IMPLOSION PROTECTION SYSTEM, BUT CARE SHOULD BE TAKEN TO AVOID DAMAGE DURING INSTALLATION, AV
15、OID SCRATCHING THE TUBE. IF SCRATCHED REPLACE IT. 2. USE ONLY RECOMMENDED FACTORY REPLACEMENT TUBES. SUBJECT : TIPS ON PROPER INSTALLATION 1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS, CUBBY- HOLE OR CLOSELY FITTING SHELF SPACE, OVER OR CLOSE TO HEAT DUCT, OR IN THE PATH OF HEATED AIR FLOW. 2.
16、 AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS: OUTDOOR PATIO INSTALLATIONS WHERE DEW IS A FACTOR, NEAR STEAM RADIA- TORS WHERE STEAM LEAKAGE IS A FACTOR, ETC. 3. AVOID PLACEMENT WHERE DRAPERIES MAY OBSTRUCT REAR VENTING. THE CUSTOMER SHOULD ALSO AVOID THE USE OF DEC- ORATIVE SCARVES OR OTHER COVERINGS
17、WHICH MIGHT OBSTRUCT VENTILATION. 4. WALL AND SHELF MOUNTED INSTALLATIONS USING A COMMER- CIAL MOUNTING KIT, MUST FOLLOW THE FACTORY APPROVED MOUNTING INSTRUCTIONS. A PRODUCT MOUNTED TO A SHELF OR PLATFORM MUST RETAIN ITS ORIGINAL FEET (OR THE EQUIVALENT THICKNESS IN SPACERS) TO PROVIDE ADEQUATE AIR
18、 FLOW ACROSS THE BOTTOM. BOLTS OR SCREWS USED FOR FASTENERS MUST NOT TOUCH ANY PARTS OR WIRING. PERFORM LEAKAGE TEST ON CUSTOMIZED INSTALLATIONS. 5. CAUTION CUSTOMERS AGAINST THE MOUNTING OF A PRODUCT ON SLOPING SHELF OR A TILTED POSITION, UNLESS THE PRODUCT IS PROPERLY SECURED. 6. A PRODUCT ON A RO
19、LL-ABOUT CART SHOULD BE STABLE ON ITS MOUNTING TO THE CART. CAUTION THE CUSTOMER ON THE HAZ- ARDS OF TRYING TO ROLL A CART WITH SMALL CASTERS ACROSS THRESHOLDS OR DEEP PILE CARPETS. 7. CAUTION CUSTOMERS AGAINST THE USE OF A CART OR STAND WHICH HAS NOT BEEN LISTED BY UNDERWRITERS LABORATORIES, INC. F
20、OR USE WITH THEIR SPECIFIC MODEL OF TELEVISION RECEIVER OR GENERICALLY APPROVED FOR USE WITH T.V.S OF THE SAME OR LARGER SCREEN SIZE. 8. CAUTION CUSTOMERS AGAINST THE USE OF EXTENSION CORDS. EXPLAIN THAT A FOREST OF EXTENSIONS SPROUTING FROM A SIN- GLE OUTLET CAN LEAD TO DISASTROUS CONSEQUENCES TO H
21、OME AND FAMILY. PRODUCT SAFETY SERVICING GUIDELINES FOR NAD PRODUCTS A.C. VOLTMETER GOOD EARTH GROUND SUCH AS THE WATER PIPE. CONDUIT. ETC PLACE THIS PROBE ON EACH EXPOSED METAL PART RadioFans.CN 收音机爱 好者资料库 Preliminar y ALIGNMENT PROCEDURE FOR NAD S400: EQUIPMENT REQUIRED FOR ALIGNMENT PROCEDURE: FM
22、 RF signal generator capable of 75MHz to 109MHz output 75 that can separately modulate left and right channels (Panasonic model # VP-7637A or equivalent) DMM with a basic accuracy of better than +/- 0.05%. High impedance (10 M) dual channel audio AC voltmeter with decibel readout with accuracy of be
23、tter than +/- 3%. Dual channel oscilloscope that has greater than 20MHz bandwidth. Non-Ferris tuning tools. ALIGNMENT PROCEDURE: WARNING: MOST OF THE ALIGNMENT POINTS AND ADJUSTMENTS ARE FOUND UNDER A SEALED BY SOLDER SHIELD. NORMALLY THERE SHOULD NOT BE A REASON FOR ACCESS TO THE ALIGNMENT POINTS A
24、ND ADJUSTMENTS, UNLESS PARTS HAVE BEEN REPLACED. ONLY ATTEMPT ALIGNMENT IF ALL EQUIPMENT MENTIONED ABOVE IS AVAILABLE AND ONLY IF QUALIFIED PERSONNEL PERFORM THE ALIGNMENT. Depending on the country, the S400 can be setup differently via the front panel buttons. Hold down the MODE button while switch